Question
What are the characteristics of the 1st and 2nd stage outputs of the D5R-1517 Inclination Sensor?
Answer
The D5R-1517 has a two-stage operation.
(1) The 1st stage output is a 1-Hz intermittent output.
The deviation of the operating angle (ON) for the 1st stage is as follows:
15 °±1.5 ° (+13.5° to 16.5°)
-15°±1.5° (-13.5° to -16.5°)
(2) The 2nd stage output is a continuous output.
+
angle: 1st stage operating angle +2°±1° (1st stage +1 to +3°)
-
angle: 1st stage operating angle -2°±1° (1st stage -1 to -3°)
Hysteresis width s not stipulated y standards.
The actual hysteresis width is 0.1° max.
The intermittent and continuous outputs are output from the same open-collector output.