Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

Lead Contents

FAQ00904 of Counters FAQ

FAQ No. FAQ00904

Primary Contents

Question

What is the relationship between the Counter's maximum counting speed and minimum signal width?

Answer



Example: 30 Hz

Indicates 30 pulses per second (1,000 ms).

Therefore,

1000 ÷ 30 = Approx. 33.3 ms

33 ÷ 2 = 16.7 ms (minimum ON signal width and OFF signal width)

Description


ON/OFF Ratio

Ratio of the count input signal's ON time to OFF time.

(The Counter's maximum counting speed is specified at an ON/OFF ratio of 1:1.)