Question
Do F3SN Safety Light Curtain and F3SH always have to be used in a set with F3SP-B1P Safety Light Curtain Control Unit?
Answer
No, it is not always necessary to use them as a set. It is possible to comply with Category 2 or Category 4 without using F3SP-B1P.
If F3SP-B1P is not used, the user must implement proper safety circuits.
F3SP-B1P is intended for the following two main applications to reduce work in system construction and wiring for safety categories.
Intended Applications of F3SP-B1P
1.Easy construction of Category 4 safety circuits for F3SN-A Series and F3SH Series, and easy construction of Category 2 safety circuits for F3SN-B Series.
2.Reduced wiring and space requirements with easy connection by using a cable with connectors on both ends (separately sold), because both sides (i.e., Safety Light Curtain and F3SP-B1P) require connectors. Refer to the following figure.