Question

What is a manual reset?

Answer



A manual reset is a selectable feature of the interlock function.

When the Safety Sensor enters the interlock state, it keeps the control outputs in the OFF state. Even if all beams become free, the control outputs will not go to the ON state.

When none of the beams are interrupted in the detection zone and it is safe to operate the device, applying the reset input will reset the interlock condition and the control outputs will go to the ON state.

Applicable models:

F3SN Series Safety Light Curtain

F3SH Series Multi Beam Safety Sensor