The rated currents for some of the built-in operation indicator models differ from the values given in this table. Refer to note 5 below.
Power Relay
about this Product Family
last update: October 15, 2012
The rated currents for some of the built-in operation indicator models differ from the values given in this table. Refer to note 5 below.
Rated voltage | Rated current |
Coil resistance |
Coil inductance (ref.value) |
Must operate |
Must release |
Max. voltage |
Power consumption |
||
---|---|---|---|---|---|---|---|---|---|
50 Hz | 60 Hz |
Armature OFF |
Armature ON |
% of rated voltage | |||||
6 VAC | 295 mA | 233 mA | 8.9 Ω | 0.048 H | 0.065 H | 80 % max. | 30 % min. | 110% | Approx. 1.4 VA |
12 VAC | 148 mA | 117 mA | 34 Ω | 0.166 H | 0.257 H | ||||
24 VAC | 73 mA | 58 mA | 136 Ω | 0.691 H | 1.04 H | ||||
50 VAC | 35 mA | 28 mA | 530 Ω | 3.08 H | 4.53 H | ||||
100/ 110 VAC | 17.7/21.4 mA | 14/16.8 mA | 2,200 Ω | 12.42/12.38 H | 18/16.4 H | ||||
200/220 VAC | 8.9/10.8 mA | 7/8.4 mA | 8,800 Ω | 42.2/41.8 H | 72/65.5 H | ||||
6 VDC | 176 mA | 34 Ω | 0.14 H | 0.26 H | 10 % min. | 110% | Approx. 1.1 W |
||
12 VDC | 88 mA | 136 Ω | 0.6 H | 1.0 H | |||||
24 VDC | 45 mA | 530 Ω | 2.7 H | 4.6 H | |||||
48 VDC | 22 mA | 2,200 Ω | 11 H | 19 H | |||||
100 VDC | 11.4 mA | 8,800 Ω | 43 H | 73 H |
Load | Resistive load (cosΦ = 1) | Inductive load (cosΦ = 0.4) (L/R = 7 ms) |
---|---|---|
Contact type | Crossbar bifurcated | |
Contact material | Movable: AgAu-clad AgPd Fixed: AgPd |
|
Rated load | 0.3 A at 110 VAC 0.5 A at 24 VDC |
0.2 A at 110 VAC 0.3 A at 24 VDC |
Rated carry current | 3 A | |
Max. switching power | 250 VAC, 125 VDC |
Classification |
Standard/Acr barrier equipped/Built-in operation indicator models (G2A-[]-N) |
Built-in diode/Built-in operation indicator models (G2A-[]-N1) |
---|---|---|
Contact resistance (see note 2) | 100 mΩ max. | |
Operate time (see note 3) | 15 ms max. | |
Release time (see note 3) | 15 ms max. | 30 ms max. |
Max. operating frequency | Mechanical: 18,000 operations/hour Electrical: 1,800 operations/hour (under rated load) |
|
Insulation resistance (see note 4) |
100 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,500 VAC, 50/60 Hz for 1 min between coil and contacts and contacts of different polarities (700 VAC between contacts of same polarity) |
|
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) |
|
Shock resistance | Destruction: 1,000 m/s2 Malfunction: 100 m/s2 |
|
Error rate (level P) (Reference value) (see note 6) |
1 mA at 100 mVDC | |
Endurance | Mechanical: 100,000,000 operations min. (at operating frequency of 18,000 operations/hour) Electrical: 5,000,000 operations min. (under rated load and at operating frequency of 1,800 operations/hour) (see note 5) |
|
Ambient temperature | Operating: -10°C to 40°C (with no icing or condensation) | |
Ambient humidity | Operating: 5% to 85% | |
Weight | Approx. 38 g |
last update: October 15, 2012