Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

P2RF, P2R, P7TF, PYF, PY, PTF, PYD, PT, P7LF, P7S, P7SA, PF, P2CF, PFA, P3G / P3GA, PL

Products Related to Common Sockets and DIN Tracks

P2RF, P2R, P7TF, PYF, PY, PTF, PYD, PT, P7LF, P7S, P7SA, PF, P2CF, PFA, P3G / P3GA, PL

A Wide Variety of Square and Round Sockets in Front-mounting and Back-mounting Models

about this Product Family

Models Used with Common Sockets

Sockets

Item Model Number
of pins
Applicable Sockets
Group name Front-mounting Back-mounting
Proximity Sensors E2C E2C-AM4A 8 P2CF-08 P3G
E2C-AK4A 11 P2CF-11 P3GA
E2C-GE4A
E2C-GF4A
8 PYF08A PY
Level Devices 61F 61F-GP-N8
61F-APN2
8 PF083A PL
61F-UHS 8PFA1
61F-HSL 8PFA
61F-03B, -04B
61F-GP-N
61F-GPN-V50
61F-GPN-BT/BC
11 PF113A
61F-IP
61F-G1P, -G2P
14 14PFA
K7L K7L-AT50/AT50D
K7L-U/-UD
8 P2RF-08(-E) ――
General-purpose
Relays and Solid-
state Relays
MY
(Q, K, H)
MY1, MY2 8 PYF PY
MY3 11
MY4, MYQ4
MY4Z-CBG
MY2K, MY4H
14
LY LY1, LY2 8 PTF PT
LY3 11
LY4 14
G7K G7K-412S ――
G2A(K) G2A, G2A-434
G2AK
14 PYF PY
MK(K) MK2P 8 PF083A(-E) PL
MK3P
MK2KP
11 PF113A(-E)
MM MM2(X)P 8 8PFA PL
MM3P
MM2(X)KP
11 PFA
MM3XP
MM3(X)KP
MM4(X)P
MM4(X)KP
14
G4Q ―― 8 8PFA1 PL
G3F G3F(D) Series
G3FM
8 PYF PY
G3H G3H(D) Series PTF PT
G3B G3B(D) Series PF083A PL
G9H G9H-2[][]S PTF PT
G2R G2R-1-S[] 5 P2RF-05[] P2R-05[]
G2R-2-S[] 8 P2RF-08[] P2R-08[]
G3R --- 5 P2RF-05[] P2R-05[]
G7T
G3TA
G7T
G3TA
5 P7TF-05 ――
G7S G7S-4A2B-E
G7S-3A3B-E
14 P7S-14F-END P7S-14P-E
G7SA G7SA-3A1B
G7SA-2A2B
10 P7SA-10F
P7SA-10F-ND
P7SA-10P
G7SA-5A1B
G7SA-4A2B
G7SA-3A3B
14 P7SA-14F
P7SA-14F-ND
P7SA-14P
Timers H3CA H3CA-8(H) 8 P2CF P3G
PL
H3CA-A 11 P3GA
PL
H5CN H5CN-[]M 11 P3GA
Other H5CN models 8 P3G
H5CX H5CX-L8[] 8 P3G
H5CX-A11[] 11 P3GA
H5CZ H5CZ-L8[] 8 P3G
H3CR H3CR-A8[]
H3CR-F8[]
H3CR-G8[]
H3CR-H8[]
8 P2CF P3G
PL
H3CR-A
H3CR-AS
H3CR-AP
H3CR-F
H3CR-FN
H3CR-HRL
11 P3GA
PL
H3M ―― 8 PF085A P3G
PL
H3Y H3Y-2 8 PYF PY
H3Y-4 14
H3YN H3YN-2[] 8
H3YN-4[] 14
H3RN H3RN-1[] 5 P2RF-[]-E P2R-[]7P
H3RN-2[] 8
RD2P --- 8 8PFA1 PL
H2C --- 8 P2CF
PF085A
P3G
PL
Counters H7CX H7CX-A11[] 11 P2CF P3GA
H7CZ H7CZ-L8[] 8 P3G
H7CN H7CN-[]M 11 P3GA
Other H7CN models 8 P3G
Temperature
Controllers
E5CN E5CN-[]U 11 P3GA
E5C2 --- 8 P3G
E5CS E5CS-[]1, []2 11 P3GA
Other E5CS models 8 P3G
E5L --- 14 PTF14A ---
Signal Converters K3FK K3FK models not listed
below
8 8PFA (Included with
Converter)
---
K3FK-G[]
K3FK-GS[]
K3FK-SL-[]5-[]
11 11PFA
(Included with Converter)
Component
Protective
Components
SE SE-KP[]N 8 8PFA1 ---
SAO SAO-[]
APR APR-S PF083A PL08
APR-S380/-S440 11 P2CF-11 PL11
K2CU K2CU-P 8 8PFA1 ---
SDV SDV-F[][]/-FH[]T PL08
SDV-D[][] 14 14PFA PL15
LG2 LG2-[] 8 PF083A PL08
K6EL K6EL-[] 11 P2CF-11 PL11 and P3GA-11
Products for High-
voltage Power
Receiving Equipment
AGF AGF-1-P5 8 8PFA1 ---
Annunciators MYA MYA-NA1, -NB1 8 PF083A PL
MYA-NA2, -NB2
MYA-LA1, -LB1
MYA-LA2, -LB2
MYA-LA12, -LB12
11 PF113A

Hold-down Clips

For Square Sockets

Sockets PYF[]A
PTF[]A
PYF08M PY[](QN)
PT[](QN)
PY[]-02
PT[]-0
Applicable models
MY[], MY[]N, MY[]-D, MY2[]-CR,
MY4[]-CR, MY4Z[]-CR,
MY[]-TU, MY2K, MY[]N-D2, LY[],
LY[]N, LY[]-TU, MYQ[],
G3H(D) Series, G3F(D) Series, G3FM, and G9H
PYC-A1 PYC
PYC-P
PYC-P
PYC-S
PYC-P
MY[]I *
LY[]I
--- PYC-P2
MY4H --- PYC-P
MY2Z[]-CR
MY3[]-CR
LY[]-CR
Y92H-3 --- PYC-1
G2A(K) Series PYC-A2 --- PYC-2
PYC-3
PYC-5
PYC-3
PYC-5
G7K PKC ---
H3Y Y92H-3 --- Y92H-4

Note: The [] in the model number is replaced with 08, 11, or 14.
* If you use a Hold-down Clip with the MY2I, you cannot use the PYF08A.
   Use the PYF14A.

For Round Sockets

Sockets PF083A
PF113A
PL08 (-Q)
PL11 (-Q)
PLE08-0
PLE11-0
P2CF-11
Applicable models
61F-03B, -04B PFC-A1 PLC PLC-10 ---
61F-GP-N, -GPN-BT
61F-GP-N8
61F-APN2
PFC-N8 PHC-5
MK2P Series, MK2KP,
MK3P[](-US), and G3B(D) Series
PFC-A1 PLC
MK3ZP
MK3LP
PLC-1
MYA-NA1, -NB1
MYA-LA1, -LB1
MYA-NA2, -NB2
MYA-LA2, -LB2
PFC-A6 PLC-7 --- ---
MYA-LA12, -LB12 PFC-A7 PLC-8 --- ---
APR-S PFC-A6 PLC-7 --- ---
APR-S380/-S440 --- --- --- Y92H-1
LG2 PFC-A7 PLC-8 --- ---
K6EL --- Y92H-1 --- ---

Note: 1. The 8PFA(1), 11PFA, and 14PFA are held with hooks.
           2. The PL15, PL20, and PF202, as well as models not given in the above table, require panel processing for
                installation.
           3. The PF085A Hold-down Clip is included with the H3M and H2A. It is an option (sold separately) for the H2C.

Specifications

Socket Characteristics

Model Continu-
ous carry
current
Dielectric strength Insulation
resistance
*1
Remarks
P2RF-05(-E)(-S) 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil and contact terminals:
4,000 VAC for 1 min
P2RF-08(-E)(-S) 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
P2R-05P 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil and contact terminals:
4,000 VAC for 1 min
P2R-08P 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
P2R-057P 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between coil and contact terminals:
5,000 VAC for 1 min
P2R-087P 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between coil and contact terminals:
5,000 VAC for 1 min
P2R-05A 10 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
1,000 MΩ min.
Between ground terminals: 1,500 VAC
for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
P2R-08A 5 A Between contact terminals of different
polarity: 3,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,000 VAC for 1 min
Between ground terminals: 1,500 VAC
for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
P7TF-05 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PYF08A(-E)(-S) 7 A, -S
models:
10 A
Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. The continuous carry
current of 10 A for the
PYF08S is for an ambient
temperature of 55°C.
At an ambient temperature
of 70°C, the value is 7 A.
PYF11A 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PYF14A(-E)(-S) 3 A, -S
models:
5 A
Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PY08(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 1,000 MΩ min.
PY08QN(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY08-02 7 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11QN(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11-02 5 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14QN(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14-02 3 A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PTF[][]A(-E) 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][] 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][]QN 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT[][]-0 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
P7LF-06 30 A Between contact terminals of different
polarity: 2,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 2,000 VAC for 1 min
Between coil and contact terminals:
4,000 VAC for 1 min
PF[][][]A 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P2CF 5 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P3G(A) 6 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
8PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
11PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PL[](-Q) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PLE[][]-0 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P6D-04P 5 A Between contact terminals of same
polarity: 1,000 VAC for 1 min
100 MΩ min.
Between coil and contact terminals:
3,000 VAC for 1 min
P7S-14[]-E(ND) 10 A Between contact terminals of different
polarity: 2,000 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,500 VAC for 1 min
Between coil and contact terminals:
2,000 VAC for 1 min
P7SA-10[] 6 A *2 Between contact terminals of different
polarity: 2,500 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,500 VAC for 1 min
Between coil and contact terminals:
2,500 VAC for 1 min
P7SA-14[] 6 A *2 Between contact terminals of different
polarity: 2,500 VAC for 1 min
1,000 MΩ min.
Between contact terminals of same
polarity: 1,500 VAC for 1 min
Between coil and contact terminals:
2,500 VAC for 1 min

*1. The insulation resistance was measured with a 500-VDC insulation resistance meter at the same places as those
       used for measuring the dielectric strength.
*2. There are restrictions in the current. Refer to the General Catalog for the OMRON Safety Components (Cat. No. Y106)
       for details.