Sensing method | Distance-settable | ||||
---|---|---|---|---|---|
Model | NPN output | E3Z-LS61 | E3Z-LS66 | E3Z-LS63 | E3Z-LS68 |
PNP output | E3Z-LS81 | E3Z-LS86 | E3Z-LS83 | E3Z-LS88 | |
Sensing
distance |
BGS | White or black paper (100 × 100 mm): 20 mm
to set distance |
2 mm to set distance (80 mm max.) | ||
FGS | White paper (100 × 100 mm): Set distance to
200 mm min. Black paper (100 × 100 mm): Set distance to 160 mm min. |
----- | |||
Setting range | White paper (100 × 100 mm): 40 to 200 mm
Black paper (100 × 100 mm): 40 to 160 mm |
White paper (25 × 25 mm): 20 to 80 mm | |||
Differential travel | 10% of set distance max. (Refer to Differential
Travel vs. Sensing Distance on Data Sheet.) |
2% of set distance max. | |||
Reflectivity
characteristic (black/white error) |
10% of set distance max. | 5% of set distance max. | |||
Light source
(wavelength) |
Red LED (680 nm) | Red LED (650 nm) | |||
Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p): 10% max. | ||||
Current consumption | 30 mA max. | ||||
Control output | Load power supply voltage: 26.4 VDC max., Load current: 100 mA max. (residual voltage 1 V
max.), Open collector output (NPN or PNP depending on model) Light-ON/Dark-ON switch selectable |
||||
BGS/FGS selection | BGS: Open or connected to GND
FGS: Connected to Vcc |
BGS: Open or connected to GND | |||
Protection circuits | Reversed power supply polarity protection, Output short-circuit protection, Mutual
interference prevention |
||||
Response time | Operate or reset: 1 ms max. | ||||
Distance setting | 5-turn endless adjuster | ||||
Ambient illumination
(Receiver side) |
Incandescent lamp: 3,000 lx max.; Sunlight: 10,000 lx max. | ||||
Ambient temperature
range |
Operating: -25 to 55°C, Storage: -40 to 70°C (with no icing or condensation) | ||||
Ambient humidity
range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | ||||
Insulation resistance | 20 MΩ min. at 500 VDC | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance | Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions | ||||
Degree of protection | IP67 (IEC 60529) | ||||
Connection method | Pre-wired (standard
lengths: 2 m and 0.5 m) |
Connector (M8,
4 pins) |
Pre-wired (standard
lengths: 2 m and 0.5 m) |
Connector (M8,
4 pins) |
|
Indicators | Operation indicator (orange), Stability indicator (green) | ||||
Weight (packed state) | Pre-wired Sensors,
2 m: Approx. 65 g |
Approx. 20 g | Pre-wired Sensors,
2 m: Approx. 65 g |
Approx. 20 g | |
Material | Case | PBT (polybutylene terephthalate) | |||
Lens | Modified polyarylate resin | ||||
Accessories | Instruction manual (Mounting Brackets must be ordered separately.) |