Sensing method | Through-beam |
Retro-reflective (with M.S.R. function) *1 |
Diffuse reflective | ||
---|---|---|---|---|---|
Model | Horizontal E3S-CT11(-M1J) | Horizontal E3S-CR 11(-M1J) | Horizontal E3S-CD11(-M1J) | Horizontal E3S-CD12(-M1J) | |
Vertical E3S-CT61(-M1J) | Vertical E3S-CR 61(-M1J) | Vertical E3S-CD61(-M1J) | Vertical E3S-CD62(-M1J) | ||
Sensing distance | 30 m | 3 m (when using E39-R1) | 700 mm (300 × 300 mm white paper) |
2 m (300 × 300 mm white paper) |
|
Standard sensing object | Opaque, 15-mm dia. min. | Opaque, 75-mm dia. min. | --- | ||
Differential travel | --- | 20% max. of sensing distance | |||
Directional angle | Emitter and Receiver: 3° to15° |
3° to 10° | --- | ||
Light source (wavelength) |
Infrared LED (880 nm) | Red LED (700 nm) | Infrared LED (880 nm) | ||
Power supply voltage |
10 to 30 VDC including 10% (p.p) ripple | ||||
Current consumption |
50 mA max. (Emitter 25 mA max. Receiver 25 mA max.) |
40 mA max. | |||
Control output | Load power supply voltage: 30 VDC max. Load current: 100 mA max. (Residual voltage: NPN output: 1.2 V max., PNP output: 2.0 V max.) Open controller output (NPN/PNP selectable) Light-ON/Dark-ON selectable |
||||
Protection circuits |
Power supply reverse polarity circuit protection, Output short- circuit protection |
Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention | |||
Response time | Operate or reset: 1 ms max. | Operate or reset 2 ms max. | |||
Sensitivity adjustment |
One-turn adjuster | Two-turn endless adjuster with an indicator | |||
Ambient illumination (Receiver side) |
Incandescent lamp: 5,000 lx max. Sunlight: 10,000 lx max. |
||||
Ambient temperature range |
Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) | ||||
Ambient humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | ||||
Insulation resistance |
20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min | ||||
Vibration resistance | Destruction: 10 to 2,000 Hz, 1.5-mm double amplitude or 300 m/s2 for 0.5 hours each in X, Y, and Z directions | ||||
Shock resistance | Destruction: 1,000 m/s2 3 times each in X, Y, and Z directions | ||||
Degree of protection | IEC60529: IP67 (in-house standards: oil-resistant), NEMA: 6P (indoors only) *2 | ||||
Connection method | Pre-wired (standard cable length: 2 m) or Pre-wired M12 Connector (standard cable length: 0.3 m) | ||||
Weight (packed state) |
Approx. 270 g (Pre-wired cable) Approx. 230 g (Pre-wired Connector (M12)) |
Approx. 160 g (Pre-wired cable) Approx. 130 g (Pre-wired Connector (M12)) |
Approx. 150 g (Pre-wired cable) Approx. 110 g (Pre-wired Connector (M12)) |
||
Material | Case | Zinc die-cast | |||
Operation panel cover |
PES (polyether sulfone) | ||||
Lens | Methacrylic resin | ||||
Mounting Bracket |
Stainless steel (SUS304) | ||||
Accessories | Mounting Bracket (with screws), Adjustment screwdriver, Instruction manual, and Reflector (only for Retro-reflective Sensors) |