Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

E5EC-800

Digital Temperature Controller (Simple Type) (48 × 96 mm)

E5EC-800

48 × 96 mm. Large White PV Display That's Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications.

about this Product Family

Model Number Legend

Models with Screw Terminals

E5EC-800 48 × 96 mm

Control output 1 Control
output 2
Auxiliary
output
Commu-
nications
Heater
burnout
Event
inputs
Power
supply
voltage
Model
Relay output - Two - - - 100 to
240 VAC
E5EC-RX2ASM-800
Voltage output - E5EC-QX2ASM-800
Linear current output - E5EC-CX2ASM-800
Relay output Relay output E5EC-RR2ASM-800
Voltage output Relay output E5EC-QR2ASM-800
Linear current output Relay output E5EC-CR2ASM-800
Relay output - 24 VAC/
VDC
E5EC-RX2DSM-800
Voltage output - E5EC-QX2DSM-800
Linear current output - E5EC-CX2DSM-800
Relay output Relay output E5EC-RR2DSM-800
Voltage output Relay output E5EC-QR2DSM-800
Linear current output Relay output E5EC-CR2DSM-800
Relay output Relay output RS-485 One Two 100 to
240 VAC
E5EC-RR2ASM-808
Voltage output Relay output E5EC-QR2ASM-808
Relay output Relay output 24 VAC/
VDC
E5EC-RR2DSM-808
Voltage output Relay output E5EC-QR2DSM-808
Relay output Relay output - Four 100 to
240 VAC
E5EC-RR2ASM-810
Voltage output Relay output E5EC-QR2ASM-810
Relay output Relay output 24 VAC/
VDC
E5EC-RR2DSM-810
Voltage output Relay output E5EC-QR2DSM-810
Linear current output Relay output RS-485 - Two 100 to
240 VAC
E5EC-CR2ASM-804
Linear current output Relay output 24 VAC/
VDC
E5EC-CR2DSM-804
Relay output (Open) * Relay output
(Close) *
- - - - 100 to
240 VAC
E5EC-PR0ASM-800
Relay output (Open) * Relay output
(Close) *
Two E5EC-PR2ASM-800
Relay output (Open) * Relay output
(Close) *
RS-485 Two E5EC-PR2ASM-804

* Position proportional control model.
Note: Draw-out-type models of the E5EC-800 are available. Ask your OMRON representative for details.

Heating and Cooling Control

Using Heating and Cooling Control

(1) Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.

Optional Products (Order Separately)

Terminal Covers

Model
E53-COV24

Waterproof Packing

Model
Y92S-P9

Note: This Waterproof Packing is provided with the Digital Temperature Controller.

Waterproof Cover

Model
Y92A-49N

Front Port Cover

Model
Y92S-P7

Note: This Front Port Cover is provided with the Digital Temperature Controller.

Mounting Adapter

Model
Y92F-51
(Two Adapters are included.)

Note: This Mounting Adapter is provided with the Digital Temperature Controller.

Current Transformers (CTs)

Hole diameter Model
5.8 mm E54-CT1
5.8 mm E54-CT1L *
12.0 mm E54-CT3
12.0 mm E54-CT3L *

* Lead wires are included with these CTs. If UL certification is required, use these CTs.