Type | Standard models | ||
---|---|---|---|
NPN output | E3NX-FA11 | E3NX-FA6 | |
PNP output | E3NX-FA41 | E3NX-FA8 | |
Connecting method | Pre-wired | Wire-saving Connector | |
Inputs/
outputs |
Outputs | 1 output | |
External inputs | --- | ||
Light source (wavelength) | Red, 4-element LED (625 nm) | ||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | ||
Power consumption *2 | At Power supply voltage of 24 VDC
Standard Models: Normal mode: 840 mW max. (Current consumption at 35 mA max.) Eco function ON: 650 mW max. (Current consumption at 27 mA max.) Eco function LO: 750 mW max. (Current consumption at 31 mA max.) Advanced Models or Model for Sensor Communications Unit: Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 28 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.) |
||
Control output | Load power supply voltage: 30 VDC max., open-collector output
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
||
External inputs | --- | ||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection,
and output reverse polarity protection |
||
Response
time |
Super-high-speed mode
(SHS) *4 |
Operate or reset for model with 1 output: 30 μs, with 2 outputs: 32 μs | |
High-speed mode (HS) | Operate or reset: 250 μs | ||
Standard mode (Stnd) | Operate or reset: 1 ms | ||
Giga-power mode (GIGA) | Operate or reset: 16 ms | ||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum
sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment |
||
Maximum connectable Units | 30 | ||
No. of
Units for mutual interference prevention |
Super-high-speed mode
(SHS) *4 |
0 | |
High-speed mode (HS) | 10 | ||
Standard mode (Stnd) | 10 | ||
Giga-power mode (GIGA) | 10 | ||
Functions | Automatic power control
(APC) |
Always enabled. | |
Dynamic power control
(DPC) |
Provided | ||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
+ OFF-delay timer: 1 to 9,999 ms |
||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||
Resetting settings *6 | Select from initial reset (factory defaults) or user reset (saved settings). | ||
Eco mode *7 | Select from OFF (digital display lit), Eco ON (digital display not lit), and
Eco LO (digital display dimmed). |
||
Bank switching | Select from banks 1 to 4. | ||
Power tuning | Select from ON or OFF. | ||
Output 1 | Select from normal detection mode or area detection mode. | ||
Output 2 | --- | ||
External input | --- | ||
Hysteresis width | Select from standard setting or user setting. For a user setting, the
hysteresis width can be set from 0 to 9,999. |
||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||
Ambient temperature range ∗8 | Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation)
within the surrounding air temperature range shown above |
||
Altitude | 2,000 m max. | ||
Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and
Z directions |
||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | ||
Weight (packed state/Sensor only) | Approx. 115 g/approx. 75 g | Approx. 60g/approx. 20g | |
Materials | Case | Polycarbonate (PC) | |
Cover | Polycarbonate (PC) | ||
Cable | PVC | ||
Accessories | Instruction Manual |