E52 (General purpose Models)

Temperature Sensor (General-purpose Models)

E52 (General purpose Models)

Sheathed Platinum Resistance Thermometers, Standard Platinum Resistance Thermometers, Sheathed Thermocouples and Standard Thermocouples

about this Product Family

Sheathed Platinum Resistance Thermometers

Element type Pt100
Class JIS class B
Sheath material SUS316 (E52-P[]AY)
ASTM316L (E52-P[]B-N, E52-P[]C-N)
Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia
Conductor type 3-conductor system
Temperature range -196°C to 450°C (in dry air)

Standard Platinum Resistance Thermometers

Element type Pt100
Class JIS class B
Protective tubing material SUS316
Conductor type 3-conductor system
Temperature range 0°C to 450°C (in dry air)

Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result.

Sheathed Thermocouples

Element type K (CA), J(IC)
Class JIS class 2 (0.75)
Thermal contact Non-grounded type
Sheath material CA: ASTM316L
IC: ASTM316L

Permissible Temperature in Dry Air

D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
1 dia. 650°C 450°C
1.6 dia. 650°C 450°C
3.2 dia. 750°C 650°C
4.8 dia. 800°C 750°C
6.4 dia. 800°C 750°C
8.0 dia. 900°C 750°C

Exposed-lead Models

E52-CA[]AY

Permissible Temperature in Dry Air

D Element wire
K (CA)
ASTM316L
1 dia. 650°C
1.6 dia. 650°C
3.2 dia. 750°C
4.8 dia. 800°C
6.4 dia. 800°C
8.0 dia. 900°C

Exposed-lead Models

E52-IC[]AY

Permissible Temperature in Dry Air

D Element wire
J (IC)
ASTM316L
1 dia. 450°C
1.6 dia. 450°C
3.2 dia. 650°C
4.8 dia. 750°C
6.4 dia. 750°C
8.0 dia. 750°C

Exposed-terminal Models

E52-CA[]B-N
E52-IC[]B-N

Permissible Temperature in Dry Air

D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
3.2 dia. 750°C 650°C
4.8 dia. 800°C 750°C
6.4 dia. 800°C 750°C
8.0 dia. 900°C 750°C

Terminal box: The permissible temperature is 0°C to 100°C.

Enclosed-terminal Models

E52-CA[]C-N
E52-IC[]C-N

Permissible Temperature in Dry Air

D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
3.2 dia. 750°C 650°C
4.8 dia. 800°C 750°C
6.4 dia. 800°C 750°C
8.0 dia. 900°C 750°C

Terminal box: The permissible temperature is 0°C to 90°C.

Standard Thermocouples

Element wire K (CA), J(IC), R(PR)
Class K (CA), J (IC) JIS class 2 (0.75)
R(PR), JIS class 2 (0.25)
Protective tubing material K (CA) SUS316
J (IC) SUS316
R (See note.) JIS ceramic cat. 1 (PT1)
JIS special ceramic (PT0)
Thermal contact Non-grounded type

Note: Specify PT1 or PT0 if the element is R.

Permissible Temperature in Dry Air (See note.)

D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 750°C 450°C
12 dia. 850°C 500°C
15 dia. 900°C 550°C
22 dia. 900°C 600°C

Note: For details on the permissible temperature, refer to Technical Guide for Temperature Sensors.

D Element wire
R
15 dia. 0°C to 1,400°C

Exposed-terminal Models

E52-CA[]B-N
E52-IC[]B-N

Permissible Temperature in Dry Air

D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 750°C 450°C
12 dia. 850°C 500°C
15 dia. 850°C 550°C
22 dia. 900°C 600°C

Enclosed-terminal Models

E52-CA[]C-N
E52-IC[]C-N

Permissible Temperature in Dry Air

D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 0 to 750°C 0 to 450°C
12 dia. 0 to 850°C 0 to 500°C
15 dia. 0 to 850°C 0 to 550°C
22 dia. 0 to 900°C 0 to 600°C

Terminal box: The permissible temperature is 0°C to 90°C.

Enclosed-terminal Models (High-temperature Use)

E52-PR[]C-N

Permissible Temperature in Dry Air

D Element wire
R
15 dia. 0°C to 1,400°C