Description | Model and appearance | Tem-
perature range (See note 2.) |
Element
type |
Conductor
type |
Class | Protective
tubing material |
Terminal
type |
|
---|---|---|---|---|---|---|---|---|
Sheathed
platinum resistance thermometer |
E52-P[]AY | -196°C to
450°C |
Pt100 | 3-
conductor system |
B | SUS316 | Exposed
lead wires |
|
E52-P[]C-N | -196°C to
450°C |
ASTM316L | Enclosed
terminals |
|||||
E52-P[]B-N | Exposed
terminals |
|||||||
Standard
platinum resistance thermometer |
E52-P[]C-N | 0°C to
450°C |
SUS316 | Enclosed
terminals |
||||
Sheathed
thermocouple |
E52-CA[]AY
E52-IC[]AY |
0°C to
900°C |
K (CA)
J (IC) |
Non-
grounded type |
2
(0.75) |
ASTM316L | Exposed
lead wires |
|
E52-CA[]B-N
E52-IC[]B-N |
Exposed
terminals |
|||||||
E52-CA[]C-N
E52-IC[]C-N |
Enclosed
terminals |
|||||||
Standard
thermocouple |
E52-CA[]B-N
E52-IC[]B-N |
SUS316 | Exposed
terminals |
|||||
E52-CA[]C-N
E52-IC[]C-N |
Enclosed
terminals |
|||||||
E52-PR[]C-N | 0°C to
1,400°C |
R (PR) | 2
(0.25) |
JIS ceramic
JIS special ceramic |
Enclosed
terminals |
before use.
2. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.