Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

SGE / SCC

Safety Edge/Edge Controller

SGE / SCC

Safety sensors to detect contacts by mounting to moving parts of hazards

Edge Controller

Model SCC-1224
SCC-1224ND
Safety edge inputs Up to five series connections on the safety edges
Response time 13 ms max.
Power supply voltage 115 VAC±5%, 3.3 VA or 24 VDC±10%, 1.5 VA
Safety output DPST-NO (Rated resistive load: 250 VAC/30 VDC 4A)
Auxiliary output SPST-NO
SCC-1224: One-shot timer that turns ON between two and three seconds after the
application of pressure to the safety edge
SCC-1224ND: Kept ON during the application of pressure to the safety edge
(Rated resistive load: 250 VAC, 2.5 A/30 VDC, 2.5 A)
Terminating resistor 8.2 kΩ
Ambient operating temperature -20 to 50°C (With no icing or condensation)
Degree of protection IP20
Terminal type Screw terminals
Terminal tightening torque 0.5 to 0.6 Nm
Mounting method DIN rail mounted
Weight (factory-set) 210 g

Safety Edge

Model SGE-125 SGE-225 *4 SGE-245
SGE-245L
SGE-365
Material *1 TPE EPDM
Material hardness 65 Shore A 68 Shore A
Max. length of a single safety edge 6.1 m
Actuation distance *2 2.6 mm 3.9 mm 7.4 mm 5.2 mm
Actuation force *2 42 N 57 N 68 N 78 N
Maximum allowable load 500 N
Overtravel distance *2 (400 N) 9.5 mm 6.7 mm 18.3 mm 33.8 mm
Maximum operation angle 2 x 30° 2 x 45°
Inactive end region *3 20 mm 40 mm 20 mm
Connecting cable 2 conductors, 0.34 mm2, Allowable bending radius: R38mm
Cable Specifications
Type: PUR (Polyurethane) Round lead cable
External diameter: 3.5 dia.
Number of conductors: 2 conductors
Cross-section of conducto: 0.34 mm2
Insulator diameter: 1.2 dia.
Mechanical durability 10,000 operations min.
Ambient temperature During operation: -10 to 55°C (with no icing),
During storage: -25 to 75°C (with no icing)
Operating ambient humidity 0 to 90%RH
Degree of protection IP65
Unit weight 0.18 kg/m 0.51 kg/m 0.77 kg/m (SGE-245)
0.82 kg/m (SGE-245L)
1.10 kg/m

*1. TPE: Thermoplastic Elastomer
      EPDM: Ethylene Propylene Rubber
*2. Values of actuation distance and actuation force are characteristic values tested according to EN 1760-2 using a test
       object of ϕ80 mm and actuating point C3 under a test temperature of 20°C and test speed v = 10 mm/s. Refer to
       “Characteristics” on Catalog for details.
*3. There is an inactive region (including an end cap) in both ends of the safety edge.
      2617_sp_2
*4. The SGE-225 can be used for finger protection.The actuation force is 20 N when the SGE-225 is used for finger
       protection.
       (Characteristic values tested according to EN 1760-2 using a test object of ϕ20 mm and actuating point C3 under a
       test temperature of 20°C and test speed v = 10 mm/s)

Mechanical Force

Material TPE EPDM
Model SGE-125 SGE-225, SGE-245, SGE-365
Features Strength * 1 2 3 4 5 6 1 2 3 4 5 6
Tear Strength (Resistance) 3 3
Ultimate Tensile Strength 3 3
Rebound Elasticity at 20°C 2 2
Resistance Against Permanent Deformation 3 4 2
Abrasion 3 3
Elongation at Tear 4 5 3
Cold Flexibility 2 2

Note: 1 = Excellent
          2 = Very good
          3 = Good
          4 = Fair
          5 = Poor
          6 = Very poor

Environmental Resistance

Material TPE EPDM
Model SGE-125 SGE-225, SGE-245, SGE-365
Features Tolerance * 1 2 3 4 5 6 1 2 3 4 5 6
Heat Stability 4 2
Oxidation Stability 1 1
UV Stability 1 1
Weather/Ozone Resistance 1 1
Flame Resistance 6 6
Gas Permeability 3 4

Note: 1 = Excellent
          2 = Very good
          3 = Good
          4 = Fair
          5 = Poor
          6 = Very poor

Chemical Resistance

Material TPE EPDM
Model SGE-125 SGE-225, SGE-245, SGE-365
Features Effects * 1 2 3 4 5 6 1 2 3 4 5 6
Water Resistance 1 1 2
Diluted Acids 1 2
Diluted Bases 1 2
Non-Oxidizing Acids 2 2
Oxidizing Acids 2 4
ASTM Oil #3 2 6
Vegetable Oils 1 2 5
Organic Solvents 2
Ester Solvents 2 3 2
Ketone Solvents (Containing Oxygen) 2 3 3
Aliphatic Hydrocarbons Solvents (Gasoline) 5
Aromatic Hydrocarbons 6
Hydrocarbons 2 3 5 6
Alcohol 1 1

Note: 1 = No Effects, Permanent Contact
          2 = Few Effects, Some Contact
          3 = Medium Effects, Some Contact
          4 = Noticeable Effects, Reduced Contact
          5 = Severe Effects, Very Brief Contact
          6 = Extreme Effects, Avoid Contact