Item | Specifications | ||
---|---|---|---|
Ambient operating temperature and humidity | 0 to 55°C, 85% max. (with no condensation) | ||
Storage ambient temperature and humidity | -20 to 65°C, 85% max. (with no condensation) | ||
Operating and storage atmosphere | No corrosive gases | ||
Vibration resistance | 10 to 60 Hz and at an acceleration of 5.88 m/s2 or less (Not to be
run continuously at the resonance point) |
||
Insulation resistance | Between power supply terminal/power terminal and FG terminal: 0.5
MΩ min. (at 500 VDC Megger) |
||
Dielectric strength | Between power supply/power line terminals and FG terminal: 1,500
VAC for 1 min at 50/60 Hz |
||
Protective structure | Built into panel | ||
International
standard |
EC directives | EMC directive | EN55011, EN61000-6-2, IEC61800-3 |
Low voltage
command |
EN61800-5-1 | ||
Machinery
directives |
EN954-1 (Cat.3), EN ISO 13849-1: 2008 (PLc,d), ISO 13849-1: 2006
(PLc,d), EN61508 (SIL2), EN62061 (SIL2), EN61800-5-2 (STO), IEC61326-3-1 (SIL2) |
||
UL standards | UL508C * | ||
CSA standards | CSA C22.2 No.14 | ||
Korean Radio Regulations (KC) | Certified |