Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

E5ER

Digital Controllers

E5ER

E5ER Digital Controllers offer high speed,high precision, and multiple I/O and use a 5-digit, 3-row LCD display for high visual clarity.

about this Product Family

Digital Controllers (When your order, specify the power supply voltage.)

Standard Controllers (100 to 240 VAC)

Size Control
type
Control mode Outputs
(control/
transfer)
Optional functions Model
Auxiliary
outputs
(SUB)
Event
inputs
Serial
com-
muni-
cations
48
×
96
mm
Basic
control
(1 loop)
Single-loop standard
control
Single-loop heating and
cooling control
2 points: Pulse
voltage and Pulse
voltage/current
4 2 No E5ER-Q4B
2 points: Current
and Current
E5ER-C4B
2 points: Pulse
voltage and Pulse
voltage/current
RS-485 E5ER-Q43B-FLK
2 points: Current
and Current
E5ER-C43B-FLK
2 points: Pulse
voltage and Pulse
voltage/current
2 (See
note 1.)
6 E5ER-QT3DB-FLK
2 points: Current
and Current
E5EAR-CT3DB-FLK
4 points: Pulse
voltage and Pulse
voltage/current
and Current
(2 points)
4 2 E5ER-QC43B-FLK
2-loop
control
2-loop standard control
Single-loop heating and
cooling control
Single-loop cascade control
Single-loop control with
remote SP
Single-loop proportional
control
2 points: Pulse
voltage and Pulse
voltage/current
2 (See
note 1.)
4 RS-485 E5ER-QT3DW-FLK
2 points: Current
and Current
E5ER-CT3DW-FLK
Position-
pro-
portional
control
(1 loop)
Single-loop position-
proportional control
(See note 2.)
Relay output
(1 open, 1 closed)
2 (See
note 1.)
4 No E5ER-PRTDF
Relay output
(1 open, 1 closed)
and 1 current
(transfer) output
4 No RS-485 E5ER-PRQ43F-FLK

Note 1: The auxiliary outputs are transistor outputs.
          2: Can be switched between close control and floating control.

Standard Controllers (24 VAC/DC)

Size Control
type
Control mode Outputs
(control/
transfer)
Optional functions Model
Auxiliary
outputs
(SUB)
Event
inputs
Serial
com-
muni-
cations
48
×
96
mm
Basic
control
(1 loop)
Single-loop standard
control
Single-loop heating and
cooling control
2 points: Pulse
voltage and Pulse
voltage/current
4 2 No E5ER-Q4B
2 points: Current
and Current
E5ER-C4B
4 points: Pulse
voltage and Pulse
voltage/current
and Current
(2 points)
4 2 RS-485 E5ER-QC43B-FLK
2-loop
control
2-loop standard control
Single-loop heating and
cooling control
Single-loop cascade
control
Single-loop control with
remote SP
Single-loop proportional
control
2 points: Pulse
voltage and Pulse
voltage/current
2 (See
note 1.)
4 RS-485 E5ER-QT3DW-FLK
2 points: Current
and Current
E5ER-CT3DW-FLK
Position-
pro-
portional
control
(1 loop)
Single-loop position-
proportional control
(See note 2.)
Relay output
(1 open, 1 closed)
2 (See
note 1.)
4 No E5ER-PRTDF
Relay output
(1 open, 1 closed)
and 1 current
(transfer) output
4 No RS-485 E5ER-PRQ43F-FLK

Note 1: The auxiliary outputs are transistor outputs.
          2: Can be switched between close control and floating control.

DeviceNet-compatible Controllers (100 to 240 VAC)

Size Control
type
Control mode Outputs
(control/
transfer)
Optional functions Model
Auxiliary
outputs
(SUB)
Event
inputs
DeviceNet
communi-
cations
48
×
96
mm
Basic
control
(1 loop)
Single-loop standard
control
Single-loop heating and
cooling control
2 points: Pulse
voltage Pulse
voltage/current
2 (See
note 1.)
2 Yes E5ER-QTB-DRT
2 points: Current
and Current
E5ER-CTB-DRT
2-loop
control
2-loop standard control
Single-loop heating and
cooling control
Single-loop cascade
control
Single-loop standard
control with remote SP
Single-loop proportional
control
2 points: Pulse
voltage Pulse
voltage/current
2 (See
note 1.)
None Yes E5ER-QTW-DRT
2 points: Current
and Current
E5ER-CTW-DRT
Position-
pro-
portional
control
(1 loop)
Single-loop position-
proportional control
(See note 2.)
Relay output
(1 open, 1 closed)
2 (See
note 1.)
None Yes E5ER-PRTF-DRT

Note: 1. The auxiliary outputs are transistor outputs.
           2. Can be switched between close control and floating control.

DeviceNet-compatible Controllers (24 VAC/DC)

Size Control
type
Control mode Outputs
(control/
transfer)
Optional functions Model
Auxiliary
outputs
(SUB)
Event
inputs
DeviceNet
communi-
cations
48
×
96
mm
Basic
control
(1 loop)
Single-loop standard
control
Single-loop heating and
cooling control
2 points: Pulse
voltage Pulse
voltage/current
2 (See
note 1.)
2 Yes E5ER-QTB-DRT
2 points: Current
and Current
E5ER-CTB-DRT
2-loop
control
2-loop standard control
Single-loop heating and
cooling control
Single-loop cascade
control
Single-loop standard
control with remote SP
Single-loop proportional
control
2 points: Pulse
voltage Pulse
voltage/current
2 (See
note 1.)
None Yes E5ER-QTW-DRT
2 points: Current
and Current
E5ER-CTW-DRT
Position-
pro-
portional
control
(1 loop)
Single-loop position-
proportional control
(See note 2.)
Relay output
(1 open, 1 closed)
2 (See
note 1.)
None Yes E5ER-PRTF-DRT

Note: 1. The auxiliary outputs are transistor outputs.
           2. Can be switched between close control and floating control.

Inspection Results

The Inspection Report can be ordered at the same time as the Digital Controller using the following model number.

Inspection Report (Sold Separately)

Descriptions Model
Inspection Report for E5ER E5ER-K

Accessories (Order Separately)

Terminal Cover (Sold Separately)

Descriptions Model
Terminal Cover for E5ER E53-COV15

Rubber Packing

Model
Y92S-P5

Note: The Rubber Packing is provided with the Digital Controller.

Mounting Adapters

Model
Y92H-9