Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well. Switches CSA Certification |
See category for classification of UL Standard and CSA Standard. Category for classification of UL Standard |
Model | Ratings | Standard No. | File No. | Category | Listed/Recognized |
---|---|---|---|---|---|
61F-GN | 100/200, 110/220, 120/240V AC | UL508 | E138234 | NKPZ2 | Recognized | 61F-G1N | UL508 | NKPZ2 | Recognized | 61F-G2N | UL508 | NKPZ2 | Recognized | 61F-G3N | UL508 | NKPZ2 | Recognized | 61F-G4N | UL508 | NKPZ2 | Recognized | 61F-IN | UL508 | NKPZ2 | Recognized | 61F-GPN-V50 | 24, 110, 120, 220, 230, 240V AC | UL508 | NKPZ2 | Recognized | 61F-GP-N | 24, 100, 110, 120, 200, 220, 230, 240V AC | UL508 | NKPZ2 | Recognized | 61F-GP-N8 | 24, 100, 110, 120, 200, 220, 230, 240V AC | UL508 | NKPZ2 | Recognized | 61F-GPN-B | 24V DC | UL61010-1 CAN/CSA C22.2 No.61010-1-04 |
E200593 | QUYX2/QUYX8 | Recognized |
Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well. Switches CSA Certification |
See category for classification of UL Standard and CSA Standard. Category for classification of UL Standard |
Model | Ratings | Standard No. | File No. | Category | Listed/Recognized | |
---|---|---|---|---|---|---|
Z-01H | 0.1A 30V DC (Resistive) 0.1A 125V AC (General Use) |
UL508 | E41515 | NRNT2 | Recognition | Z-10F | 0.6A 125V, 0.3A 250V DC (Resistive) 6A 125V, 6A 250V, 6A 480V AC (General Use) 1/10HP 125V, 1/6HP 250V AC (power rating) |
Parallel Circuit Connection | NRNT2 | Recognition | Z-10G | 0.5A, 125V DC 0.25A 250V DC (Resistive) 10A 250V AC (General Use) |
NRNT2 | Recognition | Z-15 | 0.5A 125V, 0.25A 250V DC (Resistive) 15A 125V, 15A 250V, 15A 480V AC (General Use) 1/8HP 125V, 1/4HP 250V AC (power rating) 15A 250V AC Rated for 100,000 operations |
NRNT2 | Recognition | A-20G | 0.5A 125V, 0.25A 250V DC (Resistive) 20A 125V, 20A 250V, 20A 480V AC (General Use) 1HP 125V, 2HP 250V AC (power rating) 10A 125V AC (Lamp load) |
NRNT2 | Recognition | X-10G | 10A 125V, 3A 250V DC (Resistive) | NRNT2 | Recognition | DZ-10G | 0.5A 125V, 0.25A 250V DC (Resistive) 10A 125V, 10A 250V, 2A 480V AC (General Use) 1/8HP 125V, 1/4HP 250V AC (power rating) |
NRNT2 | Recognition |
Note 1: Certification is obtained with representative models. Ask your OMRON representative for details on the standards. |
||||
Note 2. The model with a rating of 100,000 operations is different from the standard model. Specify the desired model when ordering. |
||||
Note 3. The applicable standard number is given in the Standard No. column. The certification report number is given in the File No. column. |
Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well. Switches CSA Certification |
See category for classification of UL Standard and CSA Standard. Category for classification of UL Standard |
Model | Ratings | Standard No. | File No. | Category | Listed/Recognized |
---|---|---|---|---|---|
WL | A600 (Carry current: 10 A): 120 V AC: Make: 60 A, Break: 6.0 A 240 V AC: Make: 30 A, Break: 3.0 A 480 V AC: Make: 15 A, Break: 1.5 A 600 V AC: Make: 12 A, Break: 1.2 A Max. VA: Make: 7,200 VA, Break: 720 VA |
UL508 | E76675 | NKCR/NKCR7 | Listed | WL-LE | A300 (Carry current: 10 A): 120 V AC: Make: 60 A, Break: 6.0 A 240 V AC: Make: 30 A, Break: 3.0 A Max. VA: Make: 7,200 VA, Break: 720 VA |
NKCR/NKCR7 | Listed | WL-LD | A150 (Carry current: 10 A): 120 V AC: Make: 60 A, Break: 6.0 A Max. VA: Make: 7,200 VA, Break: 720 VA10A 115V AC, 0.8A 115V DC |
NKCR/NKCR7 | Listed | WL01 | 0.1A 125V AC, 0.1A 30V DC | NKCR/NKCR7 | Listed | WL01-LE | 0.1A 125V AC | NKCR/NKCR7 | Listed | WL01-LD | 0.1A 115V AC, 0.1A 30V DC | NKCR/NKCR7 | Listed | D4A-01 (SPDT, double-break, without indicator) |
A600 (Carry current: 10 A): 120 V AC: Make: 60 A, Break: 6.0 A 240 V AC: Make: 30 A, Break: 3.0 A 480 V AC: Make: 15 A, Break: 1.5 A 600 V AC: Make: 12 A, Break: 1.2 A Max. VA: Make: 7,200 VA, Break: 720 VA |
NKCR/NKCR7 | Listed | D4A-03 (SPDT, double-break, with neon lamp) |
A300 (Carry current: 10 A): 120 V AC: Make: 60 A, Break: 6.0 A 240 V AC: Make: 30 A, Break: 3.0 A Max. VA: Make: 7,200 VA, Break: 720 VA |
NKCR/NKCR7 | Listed | D4A-05 (DPDT, double-break, simultaneous operation) D4A-07 (DPDT, double-break, sequential operation) D4A-09 (DPDT, double-break, center neutral operation) |
B600 (Carry current: 5 A): 120 V AC: Make: 30 A, Break: 3.0 A 240 V AC: Make: 15 A, Break: 1.5 A 480 V AC: Make: 7.5 A, Break: 0.75 A 600 V AC: Make: 6.0 A, Break: 0.60 A Max. VA: Make: 3,600 VA, Break: 360 VA |
NKCR/NKCR7 | Listed | D4C (Without indicator) |
B300 (Carry current: 5 A): 120 V AC: Make: 30 A, Break: 3.0 A 240 V AC: Make: 15 A, Break: 1.5 A Max. VA: Make: 3,600 VA, Break: 360 VA |
NKCR/NKCR7 | Listed | D4C (With indicator) |
B150 (Carry current: 5 A): 120 V AC: Make: 30 A, Break: 3.0 A Max. VA: Make: 3,600 VA, Break: 360 VA |
NKCR/NKCR7 | Listed | D4CC | D150 (Carry current: 1 A): 120 V AC: Make: 3.6 A, Break: 0.6 A Max. VA: Make: 432 VA, Break: 72 VA 1 A 30 VDC |
NKCR/NKCR7 | Listed | SHL-[]55 | A300 (Carry current: 10 A): 120 V AC: Make: 60 A, Break: 6.0 A 240 V AC: Make: 30 A, Break: 3.0 A Max. VA: Make: 7,200 VA, Break: 720 VA |
NKCR/NKCR7 | Listed | D4MC ZC |
A300 (Carry current: 10 A):1/2A 125V 1/4A 250 VDC Resistive 120 V AC: Make: 60 A, Break: 6.0 A 240 V AC: Make: 30 A, Break: 3.0 A Max. VA: Make: 7,200 VA, Break: 720 VA |
NKCR2/NKCR8 | Recognition | ZC-01 D4MC-C |
0.1 A, 125 V AC (Resistive) 0.1 A, 30 VDC |
NKCR2/NKCR8 | Recognition | ZE/ZV/ZV2 | 15A, 125, 250 or 480V AC 0.5A 125V DC, 0.25A 250V DC 1/8HP 125V AC, 1/4HP 250V AC |
NKCR/NKCR7 | Listed | D4E-N | A300 (Carry current: 10 A): 120 V AC: Make: 60 A, Break: 6.0 A 240 V AC: Make: 30 A, Break: 3.0 A Max. VA: Make: 7,200 VA, Break: 720 VA |
NKCR2/NKCR8 | Recognition |
Note 1.Certification is sometimes obtained with representative models. Ask your OMRON representative for details on the standards. |
|||
Note 2. The applicable standard number is given in the "Standard No." column. The certification report number is given in the "File No." column. |
Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well. Switches CSA Certification |
See category for classification of UL Standard and CSA Standard. Category for classification of UL Standard |
Model | Ratings | Standard No. | File No. | Category | Listed/Recognized | Remarks |
---|---|---|---|---|---|---|
A16 | 5A 125V AC (General Use) 3A 250V AC (General Use) 3A 30V DC (Resistive) |
UL508 | E41515 | NRNT2/NRNT8 | Recognition | Certified for the Socket. | A22 | 6A 220V AC (General Use) 10A 110V AC (General Use) |
NRNT2/NRNT8 | Recognition | Certified for the Switch Block and Lamp Socket. | A3A[]-9[]K A3A[]-9[]L |
6A 125V AC, 2A 250V AC (General Use) 4A 30V DC (Resistive) |
NRNT2/NRNT8 | Recognition | --- | A3A[]-9[]A A3A[]-9[]B |
3A 125V AC (General Use) 2A 30V DC (Resistive) |
NRNT2/NRNT8 | Recognition | A3C | 1A 125V, 0.5A 250V AC (General Use) 1A 30V DC (Resistive) 0.1A 125V AC (General Use) 0.1A 30V DC (Resistive) |
NRNT2/NRNT8 | Recognition | Certified for the Switch. | A3K | 3A 250V, 5A 125V AC (General Use) 3A 30V DC (Resistive) 0.1A 125V AC (General Use) 0.1A 30V DC (Resistive) |
NRNT2/NRNT8 | Recognition | A3P | 5A 125V, 3A 250V AC (General Use) 0.1A 125V AC (General Use) 0.1A 30V DC (Resistive) |
NRNT2/NRNT8 | Recognition | A3S | 2A 250V, 3A 125V AC (General Use) 0.1A 125V AC (General Use) 0.1A 30V DC (Resistive) |
NRNT2/NRNT8 | Recognition | M2C | Lamp 28V 1W max. | NRNT2/NRNT8 | Recognition | Certified for the main unit. | M2K | Lamp 24V DC 1W | NRNT2/NRNT8 | Recognition | M2P | Lamp 28V 1.2W max. | NRNT2/NRNT8 | Recognition | M2S | Lamp 28V 1.2W max. | NRNT2/NRNT8 | Recognition | M16 | Lamp 24V max.(Input Voltage) 120V AC(Input Voltage) with Voltage Reduction Unit 240V AC(Input Voltage) with Voltage Reduction Unit |
NRNT2/NRNT8 | Recognition | Certified for the Socket. | M22 | Lamp 120V 2.6W max.(Input Voltage) 110V AC(Input Voltage) with Voltage Reduction Unit 220V AC(Input Voltage) with Voltage Reduction Unit |
NRNT2/NRNT8 | Recognition | Certified for the Lamp Socket. |