Fiber Sensor

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Sensors CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
E3X-DAT[]-S Input:
24V DC, 40 mA, class2, LPS/LIM

Output:
24V DC, 50 mA maximum, class2, LPS/LIM
UL 61010-1
CSA C22.2 No.61010-1
E316989 QUYX2, QUYX8 Recognized
E3NX-CA11 2M
E3NX-CA21 2M
E3NX-CA41 2M
E3NX-CA51 2M
Input
:10 to 30V DC Class2
Output
:10 to 30V DC Class2
Group 1 to 3 Amplifier units
100mA max
Group 4 to 30 Amplifier units
20mA max
UL 508
CSA C22.2 No.14
E196555 NRKH, NRKH7 Listed
E3NX-FA11 2M
E3NX-FA41 2M
E3NX-FA21 2M
E3NX-FA51 2M
Input
:10 to 30V DC Class2
Output
:10 to 30V DC Class2
Group 1 to 3 Amplifier units
100mA max
Group 4 to 30 Amplifier units
20mA max
UL 508
CSA C22.2 No.14
E196555 NRKH、NRKH7 Listed
Note:Sensors with DC Power-supply Specifications of 30 V Max.
Use an OMRON Certain model of S8VS/S8VK/S8AS Power Supply or other Class-2, UL-certified power supply for Sensors with power supply specifications of 30 V max, including above certificated products, and wire in accordance with NFPA70.(Sensors without UL certificate can be used in US if they are used under these conditions) , Class-2 power supplies have output limiting capability that meets the requirements of UL 1310.)

Photoelectric Sensors

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Sensors CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
E3ZR-C Power supply voltage:
10.8 to 26.4 V dc Class 2
(12Vdc -10%, 24Vdc +10%)
Load Current:100mA max
UL508
CSA C22.2 No.14
E196555 NRKH2, NRKH8 Recognized
ZX1 Power supply voltage:
10 to 30V DC
2500 mW maximum Class2
Output:
30V DC, class2
100 mA maximum, Resistive
Input:
30V DC class2
Monitor output: 4 to 20mA
UL508
CSA C22.2 No.14
E196555 NRKH2, NRKH8 Recognized
E3S-DC Power supply voltage:
10 to 30V DC, Class 2
Power Consumption 960mW
Load current: 100 mA
UL508
CSA C22.2 No.14
E196555 NRKH, NRKH7 Listed
E3S-DB Power supply voltage:
10 to 30V DC Class 2
Output: 100 mA
UL508
CSA C22.2 No.14
E196555 NRKH, NRKH7 Listed
E3Z-F Power supply voltage:
10 to 30V DC Class 2
Output:
10 to 30V DC Class 2
100 mA max
UL508
CSA C22.2 No.14
E196555 NRKH2, NRKH8 Recognized
E3NC-LA21 2M
E3NC-LA51 2M
E3NC-LH01 2M / 5M
E3NC-LH02 2M / 5M
Input
:10 to 30V DC Class2
Output
:10 to 30V DC Class2
Group 1 to 3 Amplifier units
100mA max
Group 4 to 30 Amplifier units
20mA max
UL 508
CSA C22.2 No.14
E196555 NRKH、NRKH7 Listed
E3NC-SA21 2M
E3NC-SA51 2M
E3NC-SH100 2M
E3NC-SH250 2M
Input
:10 to 30V DC Class2
Output
:10 to 30V DC Class2
Group 1 to 3 Amplifier units
100mA max
Group 4 to 30 Amplifier units
20mA max
UL 508
CSA C22.2 No.14
E196555 NRKH、NRKH7 Listed
E3JM-10S4( )-US
E3JM-DS70S4( )-US
E3JM-R4S4( )-US
Input:
24 to 240V AC 50/60Hz
12 to 240V DC

Output:
100mA 48V DC (DC, SSR output)
UL508 E314195 NRKH
Listed
E3JM-10M4( )-US
E3JM-DS70M4( )-US
E3JM-R4M4( )-US
Input:
24 to 240V AC 50/60Hz
12 to 240V DC

Output:
3A 250V AC/3A 30V DC (Relay output)
UL508 E314195 NRKH Listed
E3G-MR19( )-US
E3G-ML79( )-US
Input:
24 to 240V AC 50/60Hz
12 to 240V DC

Output:
3A 250V AC/3A 30V DC (Relay output)
UL508
CSA C22.2 No.14
E196555 NRKH、NRKH7 Listed
Note:Sensors with DC Power-supply Specifications of 30 V Max.
Use an OMRON Certain model of S8VS/S8VK/S8AS Power Supply or other Class-2, UL-certified power supply for Sensors with power supply specifications of 30 V max, including above certificated products, and wire in accordance with NFPA70.(Sensors without UL certificate can be used in US if they are used under these conditions) , Class-2 power supplies have output limiting capability that meets the requirements of UL 1310.)

Displacement Sensors/Measurement Sensors

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Sensors CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
ZX2 Power supply voltage:
10 to 30 V DC
3,000 mW maxumum Class2

Output:
30 V DC, class2
50 mA maximum, Resistive
UL508
CSA 22.2 No.14
E196555 NRKH2, NRKH8 Recognized
ZX2-SF11 Power supply voltage:
10 to 30 V DC
720 mW, Class2

Output:
Communication, RS232C
UL508 E196555 NRKH2 Recognized
Z4W-DD1C Input:
100 to 240V AC 50/60Hz

Output:
100mA 30V DC
UL508 E41515 NRNT2 Recognized
Note:Sensors with DC Power-supply Specifications of 30 V Max.
Use an OMRON Certain model of S8VS/S8VK/S8AS Power Supply or other Class-2, UL-certified power supply for Sensors with power supply specifications of 30 V max, including above certificated products, and wire in accordance with NFPA70.(Sensors without UL certificate can be used in US if they are used under these conditions) , Class-2 power supplies have output limiting capability that meets the requirements of UL 1310.)

Vision Sensor

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Sensors CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
FH-1050/3050 --- UL508 E95399 NRAQ2/NRAQ8 Recognized
FH-L550 --- UL61010-2-201 E95399 NRAQ/NRAQ7 Listed

Proximity Sensors

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Sensors CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
E2FM
(DC type of M8 housing size in Pre-wire)
Input: 30V DC maximum, Class2
Output: 30V DC maximum, Class2
DC 2-Wire 100 mA max.
DC 3-Wire 200 mA
UL508
CSA C22.2 No.14
E196555 NRKH, NRKH7 Listed
E2EF Input: 30V DC maximum, Class2
Output: 30V DC maximum, Class2
100 mA max.
UL508
CSA C22.2 No.14
E196555 NRKH, NRKH7 Listed
E2E-X[](M)Y[]-US
E2E-X[](M)Y[]-M4
Type E2E-X2Y[][] and E2E-X5MY[][]:
Pilot Duty: 24 to 240 V AC
Make 1.2 A
Break: 0.2 A
Type E2E-X5Y[][], E2E-X10[]Y[][],18MY[][]:
Pilot Duty: 24 to 240 V AC
Make: 1.8 A
Break: 0.3 A
UL508 E329670 NKCR2 Recognized
E2E (Small-diameter) E2E-C03, E2E-S04
Input: 30V DC maximum, Class2
Output: 30V DC maximum, Class2
50 mA max.
E2E-C04, E2E-S05, E2E-C05
Input: 30V DC maximum, Class2
Output: 30V DC maximum, Class2
100 mA max.
E2E-C06
Input: 30V DC maximum, Class2
Output: 30V DC maximum, Class2
200mA max (60 C) 100mA max.(70 C)
UL508 E196555 NRKH2 Recognized
E2E-X[](M)D[]-(M1TGJ)-US
(DC 2-wire pre-wired model / DC 2-wire M12 pre-wired smart click connector model)
Power supply: 12 to 24 V DC Class2
Output:12 to 24 V DC Class2 100 mA max.
UL508 E196555 NRKH2 Recognized

E2E-X[]D[]-M[]
(DC 2-wire connector model)
Power supply:12 to 24 V DC Class 2
Out put: 12 to 24 V DC Class 2 100mA max.
Diagnostic output 50mA (E2E-X[]D1S-M1 only)
UL508 E196555 NRKH2 Recognized
E2E-X[]E-M[]、E2E-X[]F-M[]
(DC 3-wire connector model with M12,M18,M30 housing size)
Power supply: 12 to 24 V DC Class2
Output: 12 to 24 V DC Class2 200 mA max.
UL508 E196555 NRKH2 Recognized
E2E-X1R5E-M[] / E2E-X1R5F-M[]
E2E-X2ME-M[] / E2E-X2MF-M[]
(DC 3-wire connector model with M8 housing size)
Power supply: 12 to 24 V DC Class2
Output: 12 to 24 V DC Class2
200 mA max. ( less than 70℃)
100 mA max.( 70 to 85 ℃)
UL508 E196555 NRKH2 Recognized
E2B Input: 30V DC maximum, Class2
Output: 30V DC maximum, Class2
200 mA max.
UL508 E196555 NRKH Listed
E2F-X5(M)Y[]-US
E2F-X10(M)Y[]-US
Pilot Duty: 24 to 240 V AC
Make: 1.8 A
Break: 0.3 A
UL508 E329670 NKCR2 Recognized
E2F-X5(M)Y[]-53US
E2F-X10(M)Y[]-53US
Pilot Duty: 100 to 120 V AC
Make: 1.8 A
Break: 0.3 A
UL508 E329670 NKCR2 Recognized
E2K-C25MY[]-US Pilot Duty: 90 to 250 V AC
Make: 1.2 A
Break: 0.2 A
UL508
CSA C22.2 No.14
E196555 NRKH, NRKH7 Listed
E2Q6 Input: 30V DC maximum, Class2
Output: 30V DC maximum, Class2
Output current 200mA
UL508
CSA C22.2 No.14
E196555 NRKH, NRKH7 Listed
Note:Sensors with DC Power-supply Specifications of 30 V Max. 
Use an OMRON Certain model of S8VS/S8VK/S8AS Power Supply or other Class-2, UL-certified power supply for Sensors with power supply specifications of 30 V max, including above certificated products, and wire in accordance with NFPA70.(Sensors without UL certificate can be used in US if they are used under these conditions) , Class-2 power supplies have output limiting capability that meets the requirements of UL 1310.)
Model Ratings Standard No. File No. Category Listed/Recognized
B7AP-S1/M1 --- UL508 E95399 NRAQ2/NRAQ8 Recognized
Note: The above table lists series names. Ask your OMRON representative for details on certified model numbers.

Photomicro Sensors

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Sensors CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized Remarks
EE-SX97 --- UL508 E41515 NRNT2 Recognized class2
EE-SX95
EE-SX77/87
EE-SX47/67
EE-SX74/84
EE-SPX-W
EE-SPX303N/403N
EE-SPX301/401
EE-SPX30/40
EE-SPY31/41
EE-SPZ-A
EE-SPX613
EE-SPY801/802
EE-SA701/801
Note:Sensors with DC Power-supply Specifications of 30 V Max.
Use an OMRON Certain model of S8VS/S8VK/S8AS Power Supply or other Class-2, UL-certified power supply for Sensors with power supply specifications of 30 V max, including above certificated products, and wire in accordance with NFPA70.(Sensors without UL certificate can be used in US if they are used under these conditions) , Class-2 power supplies have output limiting capability that meets the requirements of UL 1310.)

Liquid Leakage Sensors

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Sensors CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
K7L-AT50/-AT50D 12 to 24V DC UL508
E138234 NKPZ2 Recognized
K7L-U/-UD 12 to 24V DC UL508
CAN/CSA-C22.2 No.14
NKPZ2/NKPZ8 Recognized
K7L-AT50B/-AT50DB/-UB/-UDB 12 to 24V DC UL508
CAN/CSA-C22.2 No.14
NKPZ/NKPZ7
NKPZ2/NKPZ8
Listed,Recognized