Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Automation Systems CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
NJ --- UL508
ANSI/ISA12.12.01
E198998 NRAG/NRAG7 Listed
NX701 ---
NX-PA9001/-PD7001 ---
NX-CIF ---
NX-OC4633 --- UL61010-2-201
ANSI/ISA12.12.01
E229703
NX-PG02/03 --- UL61010-2-201
ANSI/ISA12.12.01
E198998
NX-RS1201 ---
NX-ILM400 ---
NX series
(Except for the above)
--- UL508
ANSI/ISA12.12.01
E229703
NX1P2 Series --- UL61010-2-201
ANSI/ISA12.12.01
E229703
NX1W Series --- UL61010-2-201
ANSI/ISA12.12.01
E229703
Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Products that are certified for ANSI/ISA12.12.01 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.
Description of Hazardous Locations:
[Class]
   Class I: Locations in which flammable gases or vapors may be present in the air in sufficient quantities to be explosive or ignitable.
   Class II: Locations in which combustible dust is present.
   Class III: Locations in which easily ignitable fibers or flyings are present
   but are not airborne in sufficient quantities to ignite.
[Division]
   Division 1: Locations in which explosive or ignitable material is normally present or is present at certain times.
   Division 2: Locations in which explosive or ignitable material is not normally present (but may accidentally exist).
[Group]
   Class I:
    Group A: Acetylene
    Group B: Combustible gas/vapor, example: hydrogen
    Group C: Combustible gas/vapor, example: ethylene
    Group D: Combustible gas/vapor, example: propane

Programmable Controllers

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Automation Systems CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
C200HW-PD024, -PD025, -BC081, -ME04K, -ME08K
C200H-AD003, -ID212, -OC225
C200HE-CPU42
--- UL508
ANSI/ISA12.12.01
E198998 NRAG/NRAG7 Listed
CJ1 ---
CP1H ---
CP1W-MAD44 ---
CS1W/CS1D/CS1G/CS1H ---
NSJ5/8/10/12/15 ---
CJ2 ---
CJ1W/CS1W-SCU31 --- NRAG2/NRAG8 Recognized
CJ1W/CS1W-CRM21 --- NRAG2
CP1L/CP1E/CP1W --- E229703 NRAG/NRAG7 Listed
CJ1W-CIF21 --- UL508 E95399 NRAQ/NRAQ7 Listed
SRM1-C01-V2, -C02-V2 ---
C1000H/C2000H/3G2A5/3G2C5/C500/3G2A9 ---
C200H/C200HS ---
C200HX/C200HG/C200HE/C200HW ---
CP1W ---
CPM2C ---
CQM1 ---
CQM1H ---
CS1W/CS1D/CS1G/CS1H ---
CV500/CV1000/CVM1/CV2000/CVM1D ---
IDSC ---
W4S1-03B, -05B ---
3G8F7/3G8F8-CRM21 --- NRAQ2/NRAQ8 Recognized
3G8F7-DRM21 ---
CS1PC-PCI01H-DRM ---
Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Products that are certified for ANSI/ISA12.12.01 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.
Description of Hazardous Locations:
[Class]
   Class I: Locations in which flammable gases or vapors may be present in the air in sufficient quantities to be explosive or ignitable.
   Class II: Locations in which combustible dust is present.
   Class III: Locations in which easily ignitable fibers or flyings are present
   but are not airborne in sufficient quantities to ignite.
[Division]
   Division 1: Locations in which explosive or ignitable material is normally present or is present at certain times.
   Division 2: Locations in which explosive or ignitable material is not normally present (but may accidentally exist).
[Group]
   Class I:
   Group A: Acetylene
   Group B: Combustible gas/vapor, example: hydrogen
   Group C: Combustible gas/vapor, example: ethylene
   Group D: Combustible gas/vapor, example: propane

Networks

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Automation Systems CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
GX-ID1611, OD1611, MD1611, ID1612, OD1612, MD1612, OC1601, AD0471, DA0271, EC0211, EC0241 --- UL508
ANSI/ISA12.12.01
E229703 NRAG/NRAG7 Listed
DRT2-ID16TA, OD16TA, MD16TA, ID16ML, OD16ML, ID16MLX, OD16MLX, ID32ML, OD32ML, MD32ML ---
GX-ID1618, OD1618, MD1618, ID3218, OD3218, MD3218, ID1628, ID3228, OD1628, OD3228, MD1628, MD3228 --- NRAG2/NRAG8 Recognized
DRT2-ID32B, ID32BV, OD32B, OD32BV, MD32B, MD32BV ---
CRT1-VAD/VDA/VID/VOD/VMD/TS04P/TS04T ---
XWT-VOD/VMD ---
GX-JC --- UL508
ANSI/ISA12.12.01
E198998 NRAG/NRAG7 Listed
DRT2 ---
XWT ---
GRT1 ---
CRT1-OD16, ID16, DA02, AD04, CRS1-RPT01 --- NRAG2 Recognized
DRT2-ID16S, MD16S --- NRAG2/NRAG8
CRT1 ---
GRT1-CRT ---
CRT1B-ID02JS, ID04JS, OD02JS, OD04JS, -MD02JS --- UL508 E221438 NRAG2/NRAG8 Recognized
DRT1-COM, -232C --- UL508 E95399 NRAQ/NRAQ7 Listed
GT1-AD/DA/TS/CT ---
SRT2-ID04CL/08CL, OD04CL/08CL, AD/DA ---
CRT1B-OD02S/SP, ID02S/SP, ID04SP, MD04SLP --- NRAQ2 Recognized
B7A --- NRAQ2/NRAQ8
SRT2-BSC01, ID/MD/OD, ROC/ROF/VID/VOD ---
GT1-ID/OD/ROP/BSC/ROS ---
DCA --- UL2238 E207683 CYJV2 Recognized
DCN --- UL2238 E207683 CYJV2 Recognized
XW4 --- UL1059 E245101 XCFR2/XCFR8 Recognized
Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Products that are certified for ANSI/ISA12.12.01 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.
Description of Hazardous Locations:
[Class]
   Class II: Locations in which there is combustible dust.
   Class III: Locations in which easily ignitable fibers or flyings are present
   but are not airborne in sufficient quantities to ignite.
[Division]
   Division 1: Locations in which explosive or ignitable material is normally present or is present at certain times.
   Division 2: Locations in which explosive or ignitable material is not normally present (but may accidentally exist).
[Group]
   Class I :
   Group A: Acetylene
   Group B: Combustible gas/vapor, example: hydrogen
   Group C: Combustible gas/vapor, example: ethylene
   Group D: Combustible gas/vapor, example: propane

Wireless Units

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Automation Systems CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
WE70-AP
WE70-CL
24 VDC UL60950-1 E312669 NWGQ,NWGQ7 Listed

Programmable Terminals

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Automation Systems CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
NV4W/NV3Q --- UL508 E95399 NRAQ/NRAQ7 Listed
NT631/NT631C
NT21-ST121 --- UL508
ANSI/ISA12.12.01
E198998 NRAG/NRAG7 Listed
NT11
NSH --- UL508 E95399 NRAQ/NRAQ7 Listed
NS5/8/10/12/15 --- UL508
ANSI/ISA12.12.01
E198998 NRAG/NRAG7 Listed
NB5Q/NB7W --- UL508 E221438 NRAQ/NRAQ7 Listed
NB3Q/NB5Q/NB7W/NB10W
NA5-7W/9W/12W/15W --- UL508
ANSI/ISA12.12.01
E248610 NRAG/NRAG7 Listed
NA5-7U/9U/12U/15U
Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Products that are certified for ANSI/ISA12.12.01 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.
Description of Hazardous Locations:
[Class]
   Class I: Locations in which flammable gases or vapors may be present in the air in sufficient quantities to be explosive or ignitable.
   Class II: Locations in which there is combustible dust.
   Class III: Locations in which easily ignitable fibers or flyings are present
   but are not airborne in sufficient quantities to ignite.
[Division]
   Division 1: Locations in which explosive or ignitable material is normally present or is present at certain times.
   Division 2: Locations in which explosive or ignitable material is not normally present (but may accidentally exist).
[Group]
   Class I :
   Group A: Acetylene
   Group B: Combustible gas/vapor, example: hydrogen
   Group C: Combustible gas/vapor, example: ethylene
   Group D: Combustible gas/vapor, example: propane

RFID Systems

Regarding UL standard, product is certified by UL, but can also be certified by CSA in some cases. Check information for CSA certification as well.
Automation Systems CSA Certification
See category for classification of UL Standard and CSA Standard.
Category for classification of UL Standard
Model Ratings Standard No. File No. Category Listed/Recognized
CJ1W-V600C11
CJ1W-V600C12
CS1W-V600C11
CS1W-V600C12
Not Applicable UL508 E104818 NMTR/NMTR7 Listed
CJ1W-V680C11
CJ1W-V680C12
CS1W-V680C11
CS1W-V680C12
Not Applicable UL508 E95399 NRAQ/NRAQ7 Listed
V600-CA5D01
V600-CA5D02
Input: 24V DCV, 0.8A
V680-CA5D01-V2
V680-CA5D02-V2
Input: 24V DC, 0.8A UL508 E95399 NRAQ/NRAQ7 Listed
V680-HAM42-DRT Input: 24V DC, 0.2A
V680-HAM42-FRT Input: 24V DC, 0.3A
V680-HAM81
V680-HAM91
Input: 24V DCV, 0.15A
V680S-HMD64-ETN
V680S-HMD66-ETN
Input: 24V DC, 0.2A
V750-BA50C04-US Input: 12V DC, 2.3A
A special AC Adapter is used.
UL60950-1 E256842 NWGQ/NWGQ7 Listed
The above models have a DC power supply. Be sure the following conditions are met.
Connect to one of the following circuits ((1) or (2)).
(1)
Limited-voltage/current circuit conforming to UL508
A circuit that uses, as the power supply, the secondary wiring of an insulating transformer
Maximum voltage (no-load state): 30 Vrms (42.4 V peak) max.
and
Maximum current:
1)
8 A max. (including short-circuited state) or
2)
The current is limited with a circuit-protection device (e.g., fuse) of the ratings shown in the following table:
No-load voltage (V peak) Maximum current rating (A)
0 to 20 5.0
Greater than 20 V peak,
no greater than 30 V peak
100/Peak voltage value
(2)
A Class 2 power supply unit conforming to UL1310 or circuit with maximum voltage of 30 Vrms (42.4 V peak) that uses, as the power supply, a Class 2 transformer conforming to UL1585
Note:Listing approvals