Question
Can we set the digit of the Thumbwheel Switches to be dialed only in the range from 0 to 3?
Answer
(1) Any number can be set with the models equipped with external stoppers.
Applicable Model Number: A7BS-20[]-S
(2) The models equipped with internal stoppers are also available.
Applicable Model Number: A7D[],A7B[],A7P[]
Stoppers are attached when the units are assembled in the factory.
The position where stoppers are attached cannot be changed. They are only available by order.
Add the suffix -S[][]to the model number, specifying the range in the blanks.
Example: in the case of the range from 0 to 3: A7PS-203-S03