Isolation | Zero cross
function |
Indicator | Applicable
output load *1 |
Rated input
voltage |
Model |
---|---|---|---|---|---|
Phototriac
Coupler |
Yes | Yes
(Yellow) |
5 A at 24 to
240 VAC *2 |
5 to 24 VDC | G3NA-205B DC5-24 |
Photocoupler | 100 to 120 VAC | G3NA-205B AC100-120 | |||
200 to 240 VAC | G3NA-205B AC200-240 | ||||
Phototriac
Coupler |
10 A at 24 to
240 VAC *2 |
5 to 24 VDC | G3NA-210B DC5-24 | ||
Photocoupler | 100 to 120 VAC | G3NA-210B AC100-120 | |||
200 to 240 VAC | G3NA-210B AC200-240 | ||||
Phototriac
Coupler |
20 A at 24 to
240 VAC *2 |
5 to 24 VDC | G3NA-220B DC5-24 | ||
Photocoupler | 100 to 120 VAC | G3NA-220B AC100-120 | |||
200 to 240 VAC | G3NA-220B AC200-240 | ||||
Phototriac
Coupler |
40 A at 24 to
240 VAC *2 |
5 to 24 VDC | G3NA-240B DC5-24 | ||
Photocoupler | 100 to 120 VAC | G3NA-240B AC100-120 | |||
200 to 240 VAC | G3NA-240B AC200-240 | ||||
Phototriac
Coupler |
75 A at 24 to
240 VAC *2 |
5 to 24 VDC | G3NA-275B-UTU-2 DC5-24 | ||
Photocoupler | 100 to 120 VAC | G3NA-275B-UTU-2 AC100-240 | |||
Phototriac
Coupler |
90 A at 24 to
240 VAC *2 |
5 to 24 VDC | G3NA-290B-UTU-2 DC5-24 | ||
Photocoupler | 100 to 240 VAC | G3NA-290B-UTU-2 AC100-240 | |||
Yes | 10 A at 200 to
480 VAC |
5 to 24 VDC | G3NA-410B DC5-24 | ||
100 to 240 VAC | G3NA-410B AC100-240 | ||||
20 A at 200 to
480 VAC |
5 to 24 VDC | G3NA-420B DC5-24 | |||
100 to 240 VAC | G3NA-420B AC100-240 | ||||
40 A at 200 to
480 VAC |
5 to 24 VDC | G3NA-440B-2 DC5-24 | |||
100 to 240 VAC | G3NA-440B-2 AC100-240 | ||||
50 A at 200 to
480 VAC *2 |
5 to 24 VDC | G3NA-450B-2 DC5-24 | |||
75 A at 200 to
480 VAC *2 |
5 to 24 VDC | G3NA-475B-UTU-2 DC5-24 | |||
100 to 240 VAC | G3NA-475B-UTU-2 AC100-240 | ||||
90 A at 200 to
480 VAC *2 |
5 to 24 VDC | G3NA-490B-UTU-2 DC5-24 | |||
100 to 240 VAC | G3NA-490B-UTU-2 AC100-240 | ||||
--- | 10 A at 5 to
200 VDC |
5 to 24 VDC | G3NA-D210B DC5-24 | ||
100 to 240 VAC | G3NA-D210B AC100-240 |
Note: The standard models are certified by UL and CSA.
To order a TÜV-certified model for G3NA-205BN/210B/220B/240B/D210B, add “-UTU” to the model number.
*1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The
applicable load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in
Engineering Data on Catalog.
*2. Loss time increases under 75 VAC. (Refer to Catalog.) Confirm operation with the actual load.
To order a TÜV-certified model for G3NA-205BN/210B/220B/240B/D210B, add “-UTU” to the model number.
*1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The
applicable load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in
Engineering Data on Catalog.
*2. Loss time increases under 75 VAC. (Refer to Catalog.) Confirm operation with the actual load.