Stepping Relay Unit

G9B

Ideal for Controlling Pumps and Production Lines with Six or Twelve Stepping Circuits

Contact Ratings

Load Resistive load (cosΦ = 1)
Rated load 2 A at 250 VAC/30 VDC
Rated carry current 2 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 2 A

Characteristics

Operating voltage range 85% to 110% of rated voltage
Power consumption 24 VDC: 90 mA max.
100 or 200 VAC: 120 mA max.
Contact resistance
(See note 2.)
100 mΩ max.
Operate time (See note 3.) 50 ms max.
Release time (See note 3.) 50 ms max.
Min. pulse time (See note 4.) 100 ms max.
Error detecting time 100 ms max.
Insulation resistance
(at 500 VDC)
100 MΩ min. between the power supply, control, output, and R terminals
100 MΩ min. between the terminals, except the alarm output terminals and power output terminals
Dielectric strength 1,500 V, 50/60 Hz for 1 min between the power supply, control, output, and R and other terminals
1,500 V, 50/60 Hz for 1 min between the terminals, except the alarm output terminals and power output terminals
Noise immunity Noise level: 1.5 kV, pulse width: 50 ns/1 μs (600 V for 24-VDC model)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction: 500 m/s2
Malfunction: 200 m/s2
Endurance Mechanical: 10,000,000 steps min.
Electrical: 300,000 steps min. (See note 5.)
Error rate (See note 6.) 10 mA at 5 VDC
Ambient temperature Operating: -25°C to 55°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Terminal strength Tightening torque: 0.98 Nm
Tensile strength: 49 N
Weight Twelve-step model: approx. 450 g; Six-step model: approx. 400 g

Note: 1. The data shown above are initial values.
           2. The contact resistance was measured with 0.1 A at 5 VDC using the fall-of-potential method.
           3. The operate time and release time was measured with the rated voltage imposed with any contact bounce
                ignored at an ambient temperature of 23°C.
           4. For the step signal, set a minimum pulse time of 100 ms for both the ON time and OFF time.
           5. The electrical endurance was measured at an ambient temperature of 23°C.
           6. This value was measured at a switching frequency of 120 operations per minute.