E6C2-C

Slim Incremental 50-mm-dia. Rotary Encoder

E6C2-C

General-purpose Encoder with External Diameter of 50 mm

Model E6C2-CWZ6C E6C2-CWZ5B E6C2-CWZ3E E6C2-CWZ1X
Power supply voltage 5 VDC -5% to
24 VDC +15%,
ripple (p-p): 5% max.
12 VDC -10% to
24 VDC +15%,
ripple (p-p): 5% max.
5 VDC -5% to
12 VDC +10%,
ripple (p-p): 5% max.
5 VDC ±5%,
ripple (p-p): 5% max.
Current
consumption *1
80 mA max. 100 mA max. 160 mA max.
Resolution
(pulses/rotation)
10, 20, 30, 40, 50, 60,
100, 200, 300, 360,
400, 500, 600, 720,
800, 1,000, 1,024,
1,200, 1,500, 1,800,
2,000
100, 200, 360, 500,
600, 1,000, 2,000
10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400,
500, 600, 720, 800, 1,000, 1,024, 1,200, 1,500,
1,800, 2,000
Output phases Phases A, B, and Z 488_sp_1_1
Output configuration NPN open-collector
output
PNP open-collector
output
Voltage output (NPN
output)
Line driver output *2
Output capacity Applied voltage: 30
VDC max.
Sink current: 35 mA
max.
Residual voltage: 0.4
V max.
(at sink current of 35
mA)
Applied voltage: 30
VDC max.
Source current: 35
mA max.
Residual voltage: 0.4
V max.
(at source current of
35 mA)
Output resistance: 2

Output current: 20 mA
max.
Residual voltage: 0.4 V
max.
(at sink current of 20
mA)
AM26LS31 equivalent
Output voltage:
High level: Io = -20 mA
Low level: Is = 20 mA
Output voltage:
Vo = 2.5 V min.
Vs = 0.5 V max.
Maximum response
frequency *3
100 kHz 50 kHz 100 kHz
Phase difference
between outputs
90°±45° between A and B (1/4 T ± 1/8 T)
Rise and fall times
of output
1 μs max.
(Control output
voltage: 5 V,
Load resistance: 1 kΩ,
Cable length: 2 m)
1 μs max.
(Cable length: 2 m, Sink current: 10 mA)
0.1 μs max.
(Cable length: 2 m,
Io = -20 mA, Is = 20
mA)
Starting torque 10 mNm max.
Moment of inertia 1×10-6 kgm2 max.; 3 × 10-7 kgm2 max. at 600 P/R max.
Shaft
loading
Radial 50 N
Thrust 30 N
Maximum
permissible speed
6,000 r/min
Protection circuits Power supply reverse polarity protection, Load short-circuit protection ---
Ambient temperature
range
Operating: -10 to 70°C (with no icing), Storage: -25 to 85°C (with no icing)
Ambient humidity
range
Operating/Storage: 35% to 85% (with no condensation)
Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 500 Hz, 150 m/s2 or 2-mm double amplitude for 11 min 3 times each in X, Y,
and Z directions
Shock resistance Destruction: 1,000 m/s2 3 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP64, in-house standards: oilproof
Connection method Pre-wired Models (Standard cable length: 2 m)
Material Case: Zinc alloy, Main unit: Aluminum, Shaft: SUS420J2
Weight (packed
state)
Approx. 400 g
Accessories Instruction manual
Note: Coupling, mounting bracket and hex-head spanner are sold separately.

Note: Origin Indication
          The following illustration shows the relationship between phase Z and the origin. Set cut face D to the phase Z
          origin as shown in the illustration.

E6C2-C Specifications 2

*1. An inrush current of approximately 9 A will flow for approximately 0.3 ms when the power is turned ON.
*2. The line driver output is a data transmission circuit compatible with RS-422A and long-distance transmission is
       possible with a twisted-pair cable.(AM26LS31 equivalent)
*3. The maximum electrical response speed is determined by the resolution and maximum response frequency as
       follows:

E6C2-C Specifications 3

        This means that the E6C2-C Rotary Encoder will not operate electrically if its speed exceeds the maximum electrical
        response speed.