Model | E2K-L13MC1 | E2K-L26MC1 | ||
---|---|---|---|---|
Applicable pipes | Materials | Non-metal | ||
Size | Diameter | 8 to 11 mm | 12 to 26 mm | |
Thickness | 1 mm max. | 1.5 mm max. | ||
Detectable object | Liquid * | |||
Repeat accuracy | ±0.2 mm max. | |||
Differential travel (Reference value, varies with pipe size and liquid.) |
0.6 to 5 mm | 0.3 to 3 mm | ||
Power supply voltage (operating voltage range) |
12 to 24 VDC (10.8 to 30 VDC), ripple (p-p): 10% max. | |||
Current consumption | 12 mA max. | |||
Control output | Load current | 100 mA max. | ||
Residual voltage | 1 V max. (Load current: 100 mA, Cable length: 2 m) | |||
Sensing liquid position | Indented mark position (For details, refer to Datasheet) | |||
Indicators | Detection indicator (orange) | |||
Ambient temperature range | Operating: 0 to 55°C (with no icing or condensation), Storage: -10 to 65°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 25% to 85% (with no condensation) | |||
Temperature influence | ±4 mm of detection level at 23°C in the temperature range of 0 to 55°C (with pure water or 20% saline solution) (±6 mm for E2K-L13MC1 with pure water and a pipe diameter of 8 mm) |
|||
Voltage influence | ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
Degree of protection | IP66 (IEC) | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 70 g | |||
Materials | Case, Cover | Heat-resistant ABS | ||
Cable clamp | NBR | |||
Accessories | Two bands, Four slip-proof tubes, Instruction manual |