Model | E2K-X4ME[],
E2K-X4MF[], E2K-X4MY[] |
E2K-X8ME[],
E2K-X8MF[], E2K-X8MY[] |
E2K-X15ME[],
E2K-X15MF[], E2K-X15MY[] |
|
---|---|---|---|---|
Sensing distance | 4mm ±10% | 8 mm ±10% | 15 mm ±10% | |
Set distance *1 | 0 to 2.8 mm | 0 to 5.6 mm | 0 to 10 mm | |
Differential travel | 4% to 20% of sensing distance | |||
Detectable object | Conductors and dielectrics | |||
Standard sensing object | Grounded metal plate: 50 × 50 × 1 mm | |||
Response frequency | E and F Models: 100 Hz, Y Models: 10 Hz | |||
Power supply voltage *2
(operating voltage range) |
E and F Models: 12 to 24 VDC (10 to 30 VDC)
Y Models: 100 to 220 VAC (90 to 250 VAC) |
|||
Current consumption | E and F Models: 15 mA max. | |||
Leakage current | Y Models: 2.2 mA max. (Refer to Datasheet.) | |||
Control
output |
Load current | E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA | ||
Residual
voltage |
E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m),
Y Models: Refer to Engineering Data on Data Sheet. |
|||
Indicators | E and F Models: Detection indicator (red), Y Models: Operation indicator (red) | |||
Operation mode
(with sensing object approaching) |
E1, F1, and Y1 Models: NO
E2, F2, and Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
|||
Protection circuits | E and F Models: Reverse polarity protection, Surge suppressor, load short-circuit
protection, output reverse polarity protection, Y Models: Surge suppressor |
|||
Ambient temperature
range |
Operating/Storage: -25 to 70°C
(with no icing or condensation) |
Operating/Storage: -10 to 55°C
(with no icing or condensation) |
||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±20% max. of sensing distance at 23°C in the operating temperature range | |||
Voltage influence | E and F Models: ±2% max. of sensing distance at rated voltage at rated voltage ±20%
Y Models: ±2% max. of sensing distance at rated voltage at rated voltage ±10% |
|||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | E and F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case |
|||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
|||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
Degree of protection | IP66 (IEC), in-house standards: oil-resistant | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 65 g | Approx. 145 g | Approx. 205 g | |
Materials | Case | Heat-resistant ABS | ||
Sensing
surface |
||||
Clamping nuts | Polyacetal | |||
Accessories | Instruction manual |