Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

E3X-DRT21 / SRT21 / CIF11

Communications Units for E3X-DA-N-series Fiber Amplifiers

E3X-DRT21 / SRT21 / CIF11

Three New Communications Units for Fiber Amplifiers

Communications Units

Model E3X-DRT21 E3X-SRT21 E3X-CIF11
Communications method DeviceNet CompoBus/S RS-422
Connectable Fiber Amplifiers *1 *2 E3X-DA6 *3, E3X-DA8 *3, E3X-DAB6, E3X-DAB8, E3X-DAG6, E3X-DAG8
E3X-DA6TW *3, E3X-DA8TW *3, E3X-DA6-P *3, E39-TM1
Number of connectable Fiber Amplifiers 16 max. 14 max. 16 max.
Power supply voltage 11 to 25 VDC 14 to 26.4 VDC 11.4 to 26.4 VDC
(12 VDC -5% to 24 VDC +10%)
Internal current consumption *4 70 mA max. 30 mA max. 40 mA max.
Ambient temperature Operating: -20 to 55°C, Storage: -30 to 70°C (with no icing or condensation)
Ambient humidity 35% to 85% (with no condensation)
Weight (packed state) Approx. 150 g Approx. 200 g

*1. Connection is not supported for Pre-wired Amplifiers (e.g., E3X-DA11-N) and water-resistant Amplifiers
       (e.g., E3X-DA11V).

*2. Connection is supported for products manufactured on or after the date shown below (indicated with the lot number).
       Connection is also supported for models with "MADE IN JAPAN" on the cover underlined.

E3X-DRT21 / SRT21 / CIF11 Specifications 2

*3.Manufacturing of the E3X-DA[]TW Series was discontinued at the end of March 2012. Manufacture of the
     E3X-DA6/DA8/DA6-P will be discontinued in March 2017.
*4. Does not include the current supplied to the Fiber Amplifier.

Terminal-block Unit

Model E39-TM1
Power supply voltage *1 12 to 24 VDC ±10%, ripple (p-p) 10% max.
Sensor power supply 11 to 23 VDC (power supply voltage -1 V)
Current consumption 40 mA max. + Sensor current consumption (total: 100 mA max.)
Response speed 1.2 ms max.
Number of inputs 1 point
Input signals NPN/PNP no-voltage input (contact and non-contact), switchable
Input operating configuration N.O./ N.C., switchable
Indicators Input signal display (orange)
Ambient temperature *2 Operating:
Groups of 1 to 3 Units: -25 to 55°C (with no icing or condensation)
Groups of 4 to 8 Units: -25 to 45°C (with no icing or condensation)
Groups of 9 to 16 Units: -25 to 40°C (with no icing or condensation)
Storage: -30 to 70°C

*1. The power supply for the E39-TM1 is provided from the Communications Unit (order separately). Use an E3X-CN02
       (order separately) Connector.
*2. When 4 or more Units are grouped together, the current consumption per Unit must not exceed 75 mA.
       When using together with the E3X-DA-N Fiber Amplifiers, connect the E39-TM1 Units at the end of the group.
       In this case, the upper limit for the ambient temperature for the E3X-DA-N Amplifiers is the rated upper limit -5°C.