Power rating | 15 W | |||||
---|---|---|---|---|---|---|
Output voltage | 5 V | 12 V | 15 V | 24 V | ||
Efficiency * | 100 VAC input | 80% typ. | 84% typ. | 84% typ. | 85% typ. | |
200 VAC input | 80% typ. | 84% typ. | 84% typ. | 86% typ. | ||
230 VAC input | 80% typ. | 84% typ. | 84% typ. | 86% typ. | ||
Input | Voltage range * | Single phase, 85 to 264 VAC, 120 to 370 VDC | ||||
Frequency * | 50/60 Hz (47 to 450 Hz) | |||||
Current * | 100 VAC input | 0.32 A typ. | ||||
200 VAC input | 0.2 A typ. | |||||
Power factor | --- | |||||
Leakage
current * |
100 VAC input | 0.5 mA max. | ||||
200 VAC input | 1 mA max. | |||||
Inrush
current * (for a cold start at 25°C) |
100 VAC input | 14 A typ. | ||||
200 VAC input | 28 A typ. | |||||
Output | Rated Output Current | 3 A | 1.3 A | 1 A | 0.65 A | |
Voltage adjustment range * | -10% to 15% (with V.ADJ) | |||||
Ripple & Noise
voltage * |
100 to 240
VAC input |
40 mVp-p max. | 40 mVp-p max. | 40 mVp-p max. | 60 mVp-p max. | |
Input variation influence * | 0.5% max. | |||||
Load variation influence * | 1.0% max. | |||||
Temperature
variation influence |
100 to 240
VAC input |
0.05%/°C max. | ||||
Startup time * | 100 VAC input | 1,000 ms max. | ||||
200 VAC input | 1,000 ms max. | |||||
Hold time * | 100 VAC input | 15 ms typ. | 14 ms typ. | 15 ms typ. | 15 ms typ. | |
200 VAC input | 75 ms typ. | 70 ms typ. | 75 ms typ. | 70 ms typ. | ||
Additional
functions |
Overload protection | Yes, automatic reset | ||||
Overvoltage protection * | Yes, 120% or higher of rated output voltage, power shut off (shut off the
input voltage and turn on the input again) |
|||||
Overheat protection | No | |||||
Series operation | Yes (For up to two Power Supplies, external diodes are required.) | |||||
Parallel operation | No (However, backup operation is possible, external diodes are required.) | |||||
Remote sensing | No | |||||
Remote control | No | |||||
Output indicator | Yes (LED: Green) | |||||
Insulation | Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals)
current cutoff 20 mA |
||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current
cutoff 20 mA |
||||||
1 kVAC for 1 min. (between all output terminals and PE terminals)
current cutoff 20 mA |
||||||
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE
terminals) at 500 VDC |
|||||
Environ-
ment |
Ambient operating temperature | -20 to 70°C (Derating is required according to the temperature.) (with
no condensation or icing) |
||||
Storage temperature | -25 to 75°C (with no condensation or icing) | |||||
Ambient operating humidity | 90% max. (Storage humidity: 90% max.) | |||||
Vibration resistance | 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y,
and Z directions |
|||||
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||||
Reliability | MTBF | 135,000 hrs min. | ||||
Life expectancy * | 10 years min. | |||||
Con-
struction |
Dimensions (W×H×D) | Refer to Dimensions. | ||||
Weight | 250 g | |||||
Cooling fan | No | |||||
Degree of protection | --- | |||||
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 | ||||
EMI * | Conducted
Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | ||||
Radiated
Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | |||||
EMS | Conforms to EN 61204-3 high severity levels | |||||
Safety Standards | UL 508 (Listing, excluding models with connector option)
UL 60950-1 (Recognition, OVCII [≤ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option) CSA C22.2 No.60950-1 (excluding models with connector option) EN 50178 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2) EN 60950-1 (OVCII [≤ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16. |
|||||
Marine Standards | No | |||||
SEMI | Conforms to F47-0706 (200 VAC input) |