Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

E2EQ-[]-IL[]

IO-Link Proximity Sensor (Spatter-resistant Models)

E2EQ-[]-IL[]

IO-Link Makes Sensor Level Information Visible and Solves the Three Major Issues at Manufacturing Sites! A Proximity Sensor That Can Be Used in a Spatter Environment.

Downtime can be reduced.
Notifies you of faulty parts and such phenomena in the Sensor in real time.

The frequency of sudden failure can be decreased.
Notifies you of objects being too far or too close.

The efficiency of changeover can be improved.
The batch check for individual sensor IDs significantly decreases commissioning time.

The fluororesin coating provides exceptional spatter resistance.

[Omron’s IO-Link Compliant Equipment] Masters and Sensors Can Be Chosen to Match Your Setup Situation

Omron provides two types of Masters, a Master Unit with screw-less clamp terminal blocks and a Master Unit for M12 Smartclick connectors, as IO-Link compliant devices and Sensors for connecting to the screw-less clamp terminals or to the M12 connector terminals that support each Master.

E2EQ-[]-IL[] Features 6
E2EQ-[]-IL[] Features 7

[To those in charge of maintenance “Abnormality detection” for the shortest recovery] Detects Wiring Cable Disconnections and Errors and Improves Equipment Operation Rate Through Quick Maintenance

E2EQ-[]-IL[] Features 8

Past problems

∙ An abnormality was displayed on the abnormality display screen, but upon going to look at the equipment, no external error was detected and the cause of the stop was not understood...

∙ Those responsible for maintenance investigated the cause of the abnormality from the activity of the stopped equipment, but because the maintenance person relied on the skill he or she has to identify the abnormality and replace the failed sensor, stoppages from 2 hours to several days occur...

E2EQ-[]-IL[] Features 9

[With an IO-Link Photoelectric Sensor/Proximity Sensor] Abnormal area and phenomenon of sensors are reported in real time

When an abnormality occurs in a sensor, because you can see where the abnormality occurred and the factors estimated for it, you can go to where the abnormality occurred and recover the equipment in the shortest amount of time.
Also with wire disconnection detection, not only output wires, but also power lines can be detected unconditionally.

E2EQ-[]-IL[] Features 10

[To those in charge of maintenance “Condition monitoring” for predictive maintenance] The Proximity Sensor Indicates an Excessive Proximity to the Sensing Object. Understand the Changes in Device Condition in Advance and Reduce Sudden Stops

E2EQ-[]-IL[] Features 11

Existing problems

The detection position changes due to wear and vibration in the device’s mechanical parts and as a result, false detection and collision with the sensor have a negative impact on the device...

E2EQ-[]-IL[] Features 12

[With an IO-Link Proximity Sensor] You are notified of excessive remoteness or proximity, and the occurrence of sudden defects is greatly reduced

Constantly monitoring the position of the sensing object and notifying of excessive remoteness or proximity can be used for predictive maintenance of the device.

E2EQ-[]-IL[] Features 13

[To those in charge of production engineering “Individual identification” for the reduction of man-hours] Improving System Commissioning and Changeover Efficiency by Checking Identifications in Batches

E2EQ-[]-IL[] Features 14

Existing problems

∙ During system start-up or changeover, operators had to perform the I/O check for each of the thousands of sensors installed on the line, and it took an enormous amount of time...
∙ When a sensor is installed wrong or an error occurs, wasteful work occurred that would normally be unnecessary...

E2EQ-[]-IL[] Features 15

[With an IO-Link Photoelectric Sensor/Proximity Sensor] Without going to the site, you can check individual sensor identifications in batches, resulting in a sharp reduction of commissioning time

By checking the sensor identification (manufacturer/sensor type/model number), you can easily check mistakes such as misconnected or unconnected sensors and installation mistakes.
Also, because it is possible to program multiple sensors at once using the command language used only for the controller, it is also possible to reduce commissioning time sharply.

E2EQ-[]-IL[] Features 16

[Setup] Setting all sensors from a host device at the same time

Program all at once to reduce commissioning time and inconsistent settings

E2EQ-[]-IL[] Features 17

[I/O check] Use identification checks with HMI to prevent installation mistakes

Makes it possible to check for sensor installation mistakes before commissioning

E2EQ-[]-IL[] Features 18