Type | Standard models | Advanced models | Model for Sensor
Communications Unit *1 |
||
---|---|---|---|---|---|
NPN output | E3NX-CA11 | E3NX-CA6 | E3NX-CA21 | E3NX-CA0 | |
PNP output | E3NX-CA41 | E3NX-CA8 | E3NX-CA51 | ||
Connecting method | Pre-wired | Wire-saving
Connector |
Pre-wired | Connector for Sensor
Communications Unit |
|
I/O | Outputs | 1 output | 2 outputs | --- *3 | |
External input | --- | 1 input *2 | |||
Light source (wavelength) | White LED (420 to 700 nm) | ||||
Supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the
connector through the Sensor Communications Unit. |
|||
Power consumption *4 | At Power Supply Voltage of 24 VDC
Normal mode: 960 mW max. (Current consumption: 40 mA max.) Eco function ON: 720 mW max. (Current consumption: 30 mA max.) Eco function LO: 800 mW max. (Current consumption: 33 mA max.) |
||||
Control output | Load power supply voltage:
30 VDC max., open-collector output Load current: Groups of 1 to 3 Amplifiers: 100 mA max., Groups of 4 to 30 Amplifiers: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
--- | |||
Indications | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), NO/NC indicator (orange), Smart Tuning indicator (blue), and OUT selection indicator (orange, only on models with 2 outputs) |
||||
Protection circuits | Power supply reverse polarity protection, output
short-circuit protection, and output reverse polarity protection |
Power supply reverse
polarity protection |
|||
Sensing method | Contrast Mode:
Light intensity discrimination for RGB (initial state/after 2-point tuning) (R+G+B light intensity discrimination for 1-point tuning) Color Mode: RGB ratio discrimination |
||||
Re-
sponse time |
Super-high-speed
Mode (SHS) *5 |
Operate or reset: 50 μs (only in Contrast Mode) | |||
High-speed Mode
(HS) |
Operate or reset: 250 μs | ||||
Standard Mode
(Stnd) |
Operate or reset: 1 ms | ||||
Giga-power Mode
(GIGA) |
Operate or reset: 16 ms | ||||
Sensitivity adjustment | Smart Tuning (2-point tuning, full autotuning, or 1-point tuning (1% to 99%)) or
manual adjustment |
||||
Maximum connectable Units | 30 Units | 30 Units (When connected
to OMRON NJ-series Unit) |
|||
No. of
Units for mutual interfer- ence pre- vention *6 |
Super-high-speed
Mode (SHS) *5 |
--- | |||
High-speed Mode
(HS) |
10 Units | ||||
Standard Mode
(Stnd) |
10 Units | ||||
Giga-power Mode
(GIGA) |
10 Units | ||||
Func-
tions |
Operation mode | Contrast Mode: NO (Light-ON) or NC (Dark-ON)
Color Mode: NO (ON for match: ON for same color as registered color) or NC (ON for mismatch: ON for different color from registered color) |
|||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-
delay timer (Counted by 0.1 s in a range of 0.1 to 0.5 ms, by 0.5 ms for 0.5 to 5 ms, and by 1 ms for 5 to 9999 ms. Default: 10 ms, Error: 0.1 ms) |
||||
Zero reset | Contrast Mode only
Negative values can be displayed. (Threshold level is shifted.) |
||||
Resetting
settings *7 |
Select from initial reset (factory defaults), user reset (saved settings), or bank reset. | ||||
Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO
(digital display dimmed). |
||||
Bank switching | Select from banks 1 to 8. | ||||
Power tuning
level |
Set from 100 to 9,999. (The RGB maximum incident level at Smart Tuning is
adjusted to the power tuning level.) |
||||
Output 2 | --- | Normal, error output,
AND output, or OR output |
--- | ||
External input | --- | Select from input
OFF, tuning, fullauto tuning, emission OFF, bank 1 and 2 switching, bank 1 through 8 switching, or zero reset. |
--- | ||
Changing the displays | Threshold level and incident level, channel number and incident level, RGB display
and incident level, or bank display and incident level |
||||
Ambient illumination
(Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
Ambient temperature range | Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
|||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) within the surrounding air
temperature range shown above |
||||
Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
Vibration resistance | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each
in X, Y, and Z directions |
|||
Weight
(packed state/Sensor only) |
Approx. 115 g/
approx. 75 g |
Approx. 60g/
approx. 20g |
Approx. 115 g/
approx. 75 g |
Approx. 65 g/approx. 25 g | |
Mate-
rials |
Case | Polycarbonate (PC) | |||
Cover | Polycarbonate (PC) | ||||
Cable covering | Polyvinyl chloride (PVC) | --- | |||
Accessories | Instruction manual |