D4E-[]N

Small Sealed Switch

D4E-[]N

Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E

Approved Standards

Agency Standard File No. Approved models
UL UL508 E76675 D4E-[][]20N Switches only except for Indicator-equipped
Switches
CSA CSA C22.2 No. 14 LR45746 D4E-[][]20N Switches only except for Indicator-equipped
Switches
TÜV Rheinland EN60947-5-1 R9551015 Ask your OMRON representative for information on
approved models.
CCC (CQC) GB14048.5 2003010305086795 Ask your OMRON representative for information on
approved models.

Ratings

Rated voltage Standard load Micro load
Non-inductive load (A) Inductive load (A) Non-inductive load (A)
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5 (1)
5 (1)
1.5 (1)
1.5 (1)
3 (1)
3 (1)
2 (1)
1
1 (1)
0.5
0.1
---
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5 (1)
5 (1)
5 (1)
0.5
0.25
---
---
---
---
---
1.5 (1)
1.5 (1)
1.5 (1)
0.05
0.03
---
---
---
---
---
0.1
0.1
0.1
---
---

Minimum applicable load Standard load Micro load
160 mA at 5 VDC 1 mA at 5 VDC

Inrush current NC 10 A max.
NO 10 A max.

Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a
              connector.
          2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
          3. Lamp load has an inrush current of 10 times the steady-state current.
          4. Motor load has an inrush current of 6 times the steady-state current.

Approved Standard Ratings

UL/CSA
A300

Voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 V
240 V
10 A 60 A
30 A
6 A
3 A
7,200 720

TÜV (EN60947-5-1), CCC (GB14048.5)

D4E-[]N Specifications 8

Model Applicable category and ratings Thermal current
(Ithe)
Indicator
I II III IV
1 [] 00 AC-14 0.5 A/125 VAC 5 A ---
1 [] 10 DC-12 0.5 A/30 VDC 5 A ---
1 [] 20, 21, 22 AC-15 2A/250 VAC
DC-12 2A/48 VDC
5 A ---
1 [] 23, 24 L AC-15 2A/250 VAC 5 A Neon lamp
1 [] 23, 24 L1 DC-12 2A/12 VDC 5 A LED
1 [] 23, 24 L2 DC-12 2A/24 VDC 5 A LED
1 [] 23, 24 L3 DC-12 2A/48 VDC 5 A LED
2 [] 00 AC-14 0.1A/125 VAC 0.5 A ---
2 [] 10 DC-12 0.1A/30 VDC 0.5 A ---
2 [] 20, 21, 22 AC-14 0.1A/125 VAC
DC-12 0.1A/48 VDC
0.5 A ---
2 [] 23, 24 L AC-14 0.1A/125 VAC 0.5 A Neon lamp
2 [] 23, 24 L1 DC-12 0.1A/12 VDC 0.5 A LED
2 [] 23, 24 L2 DC-12 0.1A/24 VDC 0.5 A LED
2 [] 23, 24 L3 DC-12 0.1A/48 VDC 0.5 A LED

Note: 1. []:Actuator variation of item II
           2. AC-14 0.5 A/125 VAC means as follows:
           3. Applicable category: AC-14
                Rated operating current (Ie): 0.5 A
                Rated operating voltage (Ue): 125 VAC

Characteristics

Degree of protection IP67
Durability * Mechanical 10,000,000 operations min.
Electrical 500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed 0.1 mm/sec to 0.5 m/sec
Operating frequency Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value for the built-in switch when tested alone)
Dielectric strength Between terminals of same
polarity
1,000 VAC, 50/60 Hz for 1 min
Between each terminal and
non-current-carrying metal
part
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)
Rated insulation voltage (Ui) 250V
Pollution degree (operating environment) 3 (EN60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, IEC60269 approved)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 5 A (EN60947-5-1)
Protection against electric shock Class II (grounding not required with double insulation)
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Ambient operating temperature -10°C to +80°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 86 g (in case of roller plunger)
Note: 1. The above values are initial values.
          2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
* Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to