Model FLV-TCC4 FLV-TCC1
Number of connectable lightings 4 of standard lighting 1 of standard lighting
Applicable Lighting *1 FLV series (However, FLV-EP series and FLV-LN series are excluded.)
Applicable Cameras *2 FH-S series, FZ-S series
Applicable Image Sensor Controller FH series, FZ5 series
Input Voltage Supplied from applicable camera (12 V) or external power supply (24 V) *3
External power supply voltage 24 VDC 10% (including ripple)
Current consumption 1.5A max.
Recommended
power supply
Model S8VS-06024 (manufactured by OMRON, 24 VDC, 2.5 A, 60 W)
Connectable
lighting
12 VDC
for
camera
supply
Continuous lighting 4ch total 7.5 W max. 7.5 W max.
Trigger
lighting
Simultaneous
lighting
4ch total 7.5 W max. 7.5 W max.
Individual
lighting
7.5 W max. for 1ch
24 VDC
for
external
supply
Continuous lighting 4ch total 7.5 W max. 7.5 W max.
Trigger
lighting
Simultaneous
lighting
4ch total 15 W max. 15 W max.
Individual
lighting
15 W max. for 1ch
Drive method Constant voltage method
Lighting method Trigger lighting, Continuous lighting
Luminance
Control
Method
Duty light adjustment or voltage light adjustment
Duty light adjustment: PWM frequency of 100 kHz, light adjustment of 255 levels
Voltage light adjustment: Light adjustment of 255 levels
(all are set with image sensor controller)
Trigger lighting Lighting in synchronization with trigger input timing from the controller.
Trigger lighting delay time Ton: 30μs max.
Lighting duration setting Auto setting in accordance with shutter speed.
External Interface Camera connection cable (directly connected with the main unit)
Insulation Resistance 0.5 MΩ (100VDC)
Ambient Temperature Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or condensation)
Ambient Humidity Operating and storage: 35% to 85% (with no condensation)
Degree of Protection IP20 (IEC60529)
Vibration Resistance(destructive) 10 to 150 Hz, (0.7mm double amplitude) 80 min each in X, Y, and Z directions
Shock Resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)
Materials Case,Camera mount plate: Aluminum, Cable: FPVC
Weight Approx. 130g (including
the camera mount plate)
Approx. 120g (including
the camera mount plate)
Accessories Instruction manual(this manual), Lighting connection table, Camera Mount plate, Mounting screws (M2 set
screw x 4, M2 flat head screw x 4, M4 flat head screw x 4)
Applicable standards EN61326-1 *4

Model FLV-TCC3HB FLV-TCC1EP
Number of connectable lightings 1 of spot lighting,
2 of standard lighting
1 of spot lighting
Applicable Lighting *1 FLV series (However,
FLV-LN series are
excluded.)
FLV-EP series
Applicable Cameras *2 FH-S series, FZ-S series
Applicable Image Sensor Controller FH series, FZ5 series
Input Voltage Supplied from applicable
camera (12 V) or external
power supply (24 V) *3
Supplied from applicable
camera (12 V)
External power supply voltage 24 VDC 10% (including ripple) -
Current consumption 1.5A max. 1.0A max.
Recommended
power supply
Model S8VS-06024
(manufactured by OMRON,
24 VDC, 2.5 A, 60 W)
-
Connectable
lighting
12 VDC
for
camera
supply
Continuous lighting 0ch connection: 1,2ch
total 5.5 W max.
0ch non-connection:
1,2ch total 7.5 W max.
All FLV-EP series
can be connected.
Trigger
lighting
Simultaneous
lighting
0ch connection:
1,2ch total 5.5 W max.
0ch non-connection:
1,2ch total 7.5 W max.
Individual
lighting
7.5 W max. for 1ch
24 VDC
for
external
supply
Continuous lighting 0ch connection:
1,2ch total 5.5 W max.
0ch non-connection:
1,2ch total 7.5 W max.
-
Trigger
lighting
Simultaneous
lighting
0ch connection:
1,2ch total 14 W max.
0ch non-connection:
1,2ch total 15 W max.
Individual
lighting
15 W max. for 1ch
Drive method 0ch Constant current
method
1ch/2ch: Constant
voltage method
Constant current method
Lighting method Trigger lighting, Continuous lighting
Luminance
Control
Method
0ch Duty light adjustment or
current light adjustment
1ch/2ch Duty light adjustment or
voltage light adjustment
Duty light adjustment:
PWM frequency of 100 kHz,
light adjustment of 255 levels
current light adjustment/
Voltage light adjustment:
Light adjustment of
255 levels (all are set with
image sensor controller)
Duty light adjustment or
current light adjustment
Duty light adjustment:
PWM frequency of 100 kHz,
light adjustment of 255 levels
current light adjustment:
Light adjustment of
255 levels (all are set
with image sensor controller)
Trigger lighting Lighting in synchronization with trigger input timing from the controller.
Trigger lighting delay time Ton: 30μs max.
Lighting duration setting Auto setting in accordance with shutter speed.
External Interface Camera connection cable (directly connected with the main unit)
Insulation Resistance 0.5 MΩ (100VDC)
Ambient Temperature Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or condensation)
Ambient Humidity Operating and storage: 35% to 85% (with no condensation)
Degree of Protection IP20 (IEC60529)
Vibration Resistance(destructive) 10 to 150 Hz, (0.7mm double amplitude) 80 min each in X, Y, and Z directions
Shock Resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)
Materials Case,Camera mount plate: Aluminum, Cable: FPVC
Weight Approx. 130g (including
the camera mount plate)
Approx. 120g (including
the camera mount plate)
Accessories Instruction manual(this manual), Lighting connection table, Camera Mount plate, Mounting screws (M2 set
screw x 4, M2 flat head screw x 4, M4 flat head screw x 4)
Applicable standards EN61326-1 *4

*1. Check the lighting connection table of accessory.
*2. When mounting on model FH-S[]12, use model FH-SM12-XLC (separate sale).
*3. When supplying the power to this product from an external input power supply (24V), make sure to turn ON the
      power to this product first or at the same time with the image sensor controller. If you reverse this order,
      this product will not recognize the 24V external input, so lighting greater than 7.5W will not be possible
*4. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
      Also, the following condition is applied to the immunity test of this product.
      There are case that Lighting brightness fluctuate Max 10%.

Analog Lighting Controller for FLV Series
FLV-ATC Series

Lighting Controller for Standard Light FLV-ATC21024/-ATC41024

Model FLV-ATC21024-[] *1 FLV-ATC41024-[] *1
Number of connectable lightings 1 4
Applicable light FLV series (FLV-EP series and FLV-LN series are excluded.)
Power supply voltage *2 100 to 240 VAC, 50/60 Hz
Current consumption 1 A max.
Electricity of connectable lighting 2ch total 40 W max.
30 W max. for 1ch
4ch total 40 W max.
30 W max. for 1ch
Drive method Constant voltage method
Lighting method Trigger lighting, Continuous lighting
Intensity control method Current light adjustment: 5 A max.
Trigger lighting Lighting in synchronization with input from the trigger input terminal
Trigger lighting delay time T_on: 100 μs max.
External interface Trigger input terminal block
Dielectric strength 1500 VAC 50/60 Hz 1 min
Insulation resistance 20 MΩ (500 VDC)
Ambient temperature Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Degree of protection IP20 (IEC60529)
Vibration resistance (destructive) 10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions
Shock resistance (destructive) 150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward)
Materials Case: Aluminum
Weight Approx. 800 g
Accessories Instruction sheet, AC input cable *1
Applicable standards EN61326-1 *3

*1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix
       means type A.
*2. This product is the exclusive use for apparatus inclusion in the industrial machine field.
       This product cannot be used for the connection to electric power equipment, such as a common residence, store,
       and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
*3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
       Also, the following condition is applied to the immunity test of this product.
       There are case that Lighting brightness fluctuate Max 10%.

Lighting Controller for Spot Light FLV-ATC10405/-ATC40405

Model FLV-ATC10405-[] *1 FLV-ATC40405-[] *1
Number of connectable lightings 1 4
Applicable light FLV-EP series
Power supply voltage *2 100 to 240 VAC, 50/60 Hz
Current consumption 0.6 A max.
Electricity of connectable lighting 3 W max. 4ch total 12 W max.
3 W max. for 1ch
Drive method Constant current method
Lighting method Trigger lighting, Continuous lighting
Luminance control method Current light adjustment: 5 A max.
Trigger lighting Turning the light off in synchronization with input from the trigger input terminal
Trigger lighting delay time T_on: 1000 μs max.
External interface Trigger input terminal block
Dielectric strength 1500 VAC 50/60 Hz 1 min
Insulation resistance 20 MΩ (500 VDC)
Ambient temperature Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Degree of protection IP20 (IEC60529)
Vibration resistance (destructive) 10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions
Shock resistance (destructive) 150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward)
Materials Case: Aluminum
Weight Approx. 800 g
Accessories Instruction sheet, AC input cable *1
Applicable standards EN61326-1 *3

*1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix
       means type A.
*2. This product is the exclusive use for apparatus inclusion in the industrial machine field.
       This product cannot be used for the connection to electric power equipment, such as a common residence, store,
       and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
*3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
       Also, the following condition is applied to the immunity test of this product.
       There are case that Lighting brightness fluctuate Max 10%.

Lighting Controller for Line Light: FLV-ATC26024-100V/-200V

Model FLV-ATC26024-100V[] *1 FLV-ATC26024-200V[] *1
Number of connectable lightings 2
Applicable light FLV-LN series
Power supply voltage *2 100 to 120 VAC, 50/60 Hz 200 to 240 VAC, 50/60 Hz
Current consumption 7 A max. 4 A max.
Electricity of connectable lighting 2ch total 240 W max.
120 W max. for 1ch
Drive method Constant voltage method
Lighting method Trigger lighting, Continuous lighting
Luminance control method Current light adjustment: 5 A max.
Trigger lighting Turning the light off in synchronization with input from the trigger input terminal
Trigger lighting delay time T_on: 500 μs max.
External interface Trigger input terminal block
Dielectric strength 1500 VAC 50/60 Hz 1 min
Insulation resistance 20 MΩ (500 VDC)
Ambient temperature Operating: 0 to 40°C, Storage: -15 to 60°C (with no icing or condensation)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Degree of protection IP20 (IEC60529)
Vibration resistance (destructive) 10 to 150 Hz, (0.2 mm double amplitude) 80 min each in X, Y, and Z directions
Shock resistance (destructive) 150 m/s2 3 times each in 6 directions (up/down, left/right, forward/backward)
Materials Case: Aluminum
Weight Approx. 2.1 kg
Accessories Instruction sheet, AC input cable *1
Applicable standards EN61326-1 *3

*1. The suffixed symbol of the model name means the plug type of the accessory cable. A model name with no suffix
       means type A.
*2. This product is the exclusive use for apparatus inclusion in the industrial machine field.
       This product cannot be used for the connection to electric power equipment, such as a common residence, store,
       and small establishment, because of nonconformity with to Electrical Appliance and Material Safety Law (PSE).
*3. Electromagnetic environment: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
       Also, the following condition is applied to the immunity test of this product.
       There are case that Lighting brightness fluctuate Max 10%.