3 A at 125 VAC
2 A at 250 VAC
Microload:
0.1 A at 125 VAC
0.1 A at 30 VDC
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received certification, consult your supplier.
Lighted Pushbutton Switch (Square) Ultra Bright LED Type
about this Product Family
last update: October 15, 2013
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC
250 VAC |
3
2 |
1
0.7 |
0.7
0.5 |
2
1.5 |
1.5
1 |
1
0.7 |
||
8 VDC
14 VDC 30 VDC 125 VDC 250 VDC |
3
3 2 0.4 0.2 |
1
1 1 0.05 0.03 |
2
1.5 1.5 0.4 0.2 |
1.5
1.5 1 0.05 0.03 |
Rating | 0.1 A at 30 VDC (resistive load);
0.1 A at 125 VAC (resistive load) |
---|---|
Minimum applicable load | 1 mA at 5 VDC |
Applied voltage | Rated voltage | Rated current |
---|---|---|
5 VDC±5% | 5 VDC | 8 mA |
12 VAC/VDC±5% | 12 VAC/VDC | |
24 VAC/VDC±5% | 24 VAC/VDC |
Operating
frequency |
Mechanical | Momentary operation models: 120 operations/min max. *1 |
---|---|---|
Electrical | 20 operations/min max. | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact
resistance |
Standard load | 50 mΩ max. (initial value) |
Microload | 50 mΩ max. (initial value) | |
Dielectric
strength |
Between terminals of same polarity | 1,000 VAC, 50/60 Hz for 1 minute |
Between terminals of different polarity | 2,000 VAC, 50/60 Hz for 1 minute | |
Between current-carrying metal part
and ground |
2,000 VAC, 50/60 Hz for 1 minute | |
Between each terminal and non-
current-carrying metal part |
2,000 VAC, 50/60 Hz for 1 minute | |
Between lamp terminals | 1,000 VAC, 50/60 Hz for 1 minute *2 | |
Vibration
resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *3 |
Shock
resistance |
Destruction | 500 m/s2 max. |
Malfunction | 200 m/s2 max. *3 | |
Life
expectancy |
Mechanical | Momentary operation models: 1,000,000 operations min.
Alternate operation models: 100,000 operations min. (One operation consists of set and reset operations.) |
Electrical | 100,000 operations min. (rated load) | |
Weight | Approx. 10 g | |
Inrush
current |
NC | Standard load: 10 A max. |
NO | Standard load: 10 A max. | |
Ambient operating temperature | -10 to 50°C (with no icing or condensation) | |
Ambient operating humidity | 35% to 85% RH | |
Ambient storage temperature | -25 to 65°C (with no icing or condensation) | |
Degree of protection | IP00 | |
Electric shock protection class | Class II | |
PTI (proof tracking index) | 175 | |
Pollution degree | 3 (IEC 60947-5-1) |
*1. With alternate operation models, 60 operations/min max. One operation cycle consists of set and reset operations.
*2. With no incandescent lamp or LED lamp mounted.
*3. Malfunction : 1 ms max.
Operation | Momentary operation models | Alternate operation models | |
---|---|---|---|
Operating characteristics | |||
Operating force | OF max. | 3.92 N | 4.90 N |
Releasing force | RF min. | 0.49 N | 0.294 N |
Total travel | TT | Approx. 3 mm | Approx. 3 mm |
Pretravel | PT max. | 2.2 mm | 2.2 mm |
Lock travel alternate | LTA min. | - | 0.5 mm |
Name | Contact Form |
---|---|
Double-throw contacts |
last update: October 15, 2013