D6FZ-FGT Series

Air Flow Sensor

D6FZ-FGT Series

The best Product to Measure Compressed Air at Machine. Measurement of Leakage and Usage.

about this Product Family

Ratings

Air Flow Sensor

Model D6FZ-FGT200 D6FZ-FGT500
Applicable fluid Air or nitrogen (N2) *1
Maximum working pressure 0.75 MPa (withstand pressure: 1.5 MPa)
Measurement range *2 0 to 200 L/min 0 to 500 L/min
Measurement range for
specified accuracy *2
2 to 200 L/min 5 to 500 L/min
Display resolution *2 1 L/min
Accuracy *2 ±2.0% F.S. at 50 L/min or higher
±0.5% F.S. at less than 50 L/min
Temperature characteristic ±3% F.S.
Repeat accuracy ±1% F.S.
Operating temperature Operation: -10 to 60°C, Storage: -20 to 70°C (with no condensation or icing)
Operating humidity Operation: 25% to 90% RH, Storage: 0% to 90% RH (with no condensation or icing)
Shock resistance (destruction) 150 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Pressure loss 2 kPa max. 4 kPa max.
Power supply voltage 12 to 24 VDC ±10% ripple (p-p): 10% max.
Current consumption 120 mA max.
Functions Momentary flow, total flow, display reversal, zero point adjustment, peak and bottom
hold, key lock, eco mode, scaling (analog output), judgement hysteresis, and
teaching
Indications 11-segment digital display (red); RUN, FUN, and THR (yellow); Out1 and Out2
(yellow); key lock (yellow); flow unit (green); and flow unit on reversed display (yellow)
Output Output
interface
Analog Current output: 4 to 20 mA (1 output), Maximum load resistance: 300 Ω
ON/OFF Open-collector output (2 outputs): 26.4 VDC 50 mA max.
ON residual voltage: 2 V max. (Outputs can be selected from judgement output, pulse
output, and Sensor error output.)
RS-485 2-wire half-duplex communications with start-stop synchronization
Baud rate: 9.6, 19.2, 38.4, or 115.2 kbps, Data bit length: 7 or 8 bits, Stop bit length: 1
or 2 bits, Parity: none, even, or odd, Terminating resistance (120 Ω): ON/OFF,
Communications protocol: Conforms to CompoWay/F.
Output values Momentary flow, Integrated flow, Judgement output *3, Unit error output
Degree of protection IP65
Installation Direction and
Straight Pipe Section
A straight pipe section must be provided during installation and piping if the Sensor is
installed horizontally and the display is on the top. *4
Connection pipe diameter Rc1/4 (8 A) Rc1/2 (15 A)
Materials Main unit: PBT, Flow channel: Zinc
Dimensions 30 × 77 × 63.7 mm (W × D × H)
Weight (in package) Approx. 400 g (500 g)
Accessories Instruction Sheet

*1. Clean dry gas (Must not contain large particles, e.g. dust, oils, or mist.)
*2. The flow rates are converted for the following conditions. Standard flow rate (std): 1 atmospheric pressure (101.3 kPa)
       at 20°C (default setting) Normal flow rate (nor): 1 atmospheric pressure (101.3 kPa) at 0°C
*3. To prevent chattering, a judgement output is made when the judgement continues for one minute or longer.
*4. The accuracy will depend on the length of the straight pipe section. Refer to Flow rate accuracy characteristics for a
       length of straight pipe on page 12 for details.

Air Flow Station

Model D6FZ-FGX21
Connectable Sensors D6FZ-FGT200, D6FZ-FGT500, and D6FZ-FGS1000
Maximum number of
connected Sensors
8 *1
Indications 7-segment 5-digit 2-row LCD, auxiliary information indicators
Recording interval 1 s, 2 s, 5 s, 10 s, 20 s, 30 s, or 1 min
Displayed data Momentary flow rate, total flow rate, pressure, temperature, and billing amount/CO2
conversion
Recorded data Momentary flow rate, total flow rate, volume flow rate, pressure, and temperature
Calculation functions Conversion of total flow rate to billing amount/CO2
Recording modes Continue Mode *2 and Ring Mode *3
External output Alarm output (photocoupler output) *4
Communications interface Ethernet (10Base-T or 100Base-TX)
Internal storage device Internal memory: Approx. 4,200 data items when 1 Sensor is connected, Approx. 650
data items when 8 Sensors are connected.
External storage device SD card (to save measured values and to save/read set values), Recommended SD
card: HMC-SD291 (manufactured by OMRON) *5
Power supply voltage DC input: 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption 80 mA max.
Operating temperature Without Ethernet: -10 to 40°C (with no condensation or icing), with Ethernet: 0 to 40°C
(with no condensation or icing)
Operating humidity 35% to 85% RH (with no condensation or icing)
Storage humidity/
temperature
-15 to 60°C, 20% to 85% RH (with no condensation or icing)
Insulation resistance 20 MΩ (at 500 VDC)
Withstand voltage 1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destruction)
10 to 150 Hz with a 0.7-mm double amplitude or acceleration of 50 m/s2 for 80 min
each in X, Y, and Z directions
Shock resistance
(destruction)
150 m/s2 3 times each in six directions (up/down, left/right, forward/backward) *6
Material ABS
Degree of protection IP30
Mounting method Magnet mounting, screw mounting, or hooks
Dimensions 117.2 × 24.6 × 56.8 mm (W×D×H) (excluding protruding parts)
Weight (in package) Approx. 150 g (Approx. 500 g)
Accessories Instruction Sheet, Startup Guide, Connection Cable, *7 Alarm Output Connector *8

*1. Up to 8 Sensors can be connected when the recording cycle is 2 seconds or longer; up to 4 Sensors can be connected
      when the recording cycle is 1 second.
*2. Data is automatically written to the SD memory card when the internal memory reaches its capacity and recording
     continues until the SD memory card capacity is reached. Recording stops if there is no SD memory card inserted, when
     the internal memory capacity is reached, or when the SD memory card is write protected. (Recording can be resumed
     after inserting an SD memory card and outputting the data to it by pressing a button.) The default is Continue Mode. Use
     the PC Software to change the recording mode.
*3. Recording of the latest measured values continues until the internal memory reaches its capacity. (If the internal
     memory capacity is exceeded, data is overwritten from the oldest data in the memory.)
*4. An alarm is output when the upper or lower limit of the air flow that was set in threshold setting mode is exceeded.
*5. You can temporarily read and write data with an SD card that complies with SD/SDHC card standards and was made by
     another company, but the SD card may suddenly not be recognized, preventing you from accessing the data.
*6. When mounting the Sensor with magnets, be sure to install it in a location where it will not be subjected to shock.
*7. A T-branch connector to connect to D6FZ-FC02.
*8. OMRON's XW4B-02B1-H1 Connector.