Agency | Standard | File No. |
---|---|---|
TÜV Product Service | EN60947-5-1 | *1, 3 |
UL | UL508 | E76675 *2 |
CSA | CSA C22.2 No.14 | LR45746 *2 |
CCC(CQC) | GB14048.5 | 2003010305077626 *3 |
Enclosed Switch
about this Product Family
last update: March 01, 2016
Agency | Standard | File No. |
---|---|---|
TÜV Product Service | EN60947-5-1 | *1, 3 |
UL | UL508 | E76675 *2 |
CSA | CSA C22.2 No.14 | LR45746 *2 |
CCC(CQC) | GB14048.5 | 2003010305077626 *3 |
*1. Models with VCTF, VCTF oil-resistant cables and pre-wired models only.
(Applicable only to standard models listed on Lineup.)
“CE” mark is applicable only for VCTF oil-resistant cables and pre-wired models.
*2. SJT(O)-cable models only.
(Applicable only to models listed on Lineup.)
*3. Ask your OMRON representative for information on approved models.
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC |
5 (0.1) 5 |
1.5 1 |
0.7 0.5 |
3 2 |
2.5 1.5 |
1.3 0.8 |
||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
5 (0.1) 5 (0.1) 4 (0.1) 0.4 0.2 |
2 2 2 0.05 0.03 |
5 4 3 |
4 4 3 |
3 3 3 0.05 0.03 |
|||
0.4 0.2 |
Inrush current | NC | 20 A max. |
---|---|---|
NO | 10 A max. |
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC | 1 | 1 | 1 | 0.7 | 1 | 1 | 1 | 1 |
30 VDC | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Model | Applicable category and ratings | I the |
---|---|---|
D4C-1[][][] | AC-15 2 A/250 V
DC-12 2 A/30 V |
5 A
4 A |
D4C-2[][][] | AC-15 2 A/125 V | 5 A |
D4C-3[][][] | DC-12 2 A/30 V | 4 A |
D4C-4[][][] | AC-14 0.1 A/125 V
DC-12 0.1 A/30 V |
0.5 A
0.5 A |
D4C-5[][][] | AC-14 0.1 A/125 V | 0.5 A |
D4C-6[][][] | DC-12 0.1 A/30 V | 0.5 A |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC
240 VAC |
5 A | 30
15 |
3
1.5 |
3,600
3,600 |
360
360 |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 5 A | 30 | 3 | 3,600 | 360 |
Degree of protection | IP67 | |
---|---|---|
Durability *1 | Mechanical *3 | 10,000,000 operations min. |
Electrical *2 | 200,000 operations min. (5 A at 125 VAC, resistive load) | |
Operating speed | 0.1 mm/s to 0.5 m/s (in case of plunger)
1 mm/s to 1 m/s (in case of roller lever) |
|
Operating frequency | Mechanical | 120 operations/min |
Electrical | 30 operations/min | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance (initial) | 250 mΩ max. (initial value with 2-m VCTF cable)
300 mΩ max. (initial value with 3-m VCTF cable) 400 mΩ max. (initial value with 5-m VCTF cable) |
|
Dielectric strength | Between terminals of the same polarity | 1,000 VAC, 50/60 Hz for 1 min |
Between current-carrying metal part
and ground |
1,500 VAC, 50/60 Hz for 1 min
Uimp: 2.5 kV (EN60947-5-1) |
|
Between each terminal and non-
current-carrying metal part |
1,500 VAC, 50/60 Hz for 1 min
Uimp: 2.5 kV(EN60947-5-1) |
|
Rated insulation voltage (Ui) | 300 V (EN60947-5-1) *5 | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A fuse type gI or gG (IEC60269) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (I the) | 5 A, 4 A, 0.5 A (EN60947-5-1) | |
Protection against electric shock | Class I (with grounding wire) *6 | |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *4 |
Shock resistance | Destruction | 1,000 m/s2 max. |
Malfunction | 500 m/s2 max. *4 | |
Ambient operating temperature | -10°C to +70°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight (D4C-1202) | With 3-m VCTF cable: 360 g
With 5-m VCTF cable: 540 g |