Approved Standard Ratings

Certification Authority UL *1 *2 CSA *1 *2 TÜV*3
Certification no. UL508
CSA C22.2 No.14
CSA C22.2 No. 14 EN60947-5-1
Rating 30 VDC 0.1 A 30 VDC 0.1 A 12 30 VDC 0.1 A
File no. E41515 2650068 J50236157

*1. Only Switch Blocks are recognized by UL/CSA. (Surrounding air Temperature: 55 °C)
*2. Please use the power supply specified in UL/CSA class 2.
*3. Use 4A 250V as short-circuit protective device when using under EN-compliant rating standard (IEC60127-2 SS1).

Ratings

Contacts
30 VDC, 0.1 A (Resistive load)
Minimum applicable load: 1 mA at 5 VDC

Rated values are obtained from tests conducted under the following conditions.
1. Load: Resistive load
2. Mounting conditions: No vibration and no shock
3. Temperature: 20 ± 2 °C
4. Operating frequency: 20 operations/min

Super-bright LED

Rated voltage Rated current Operating voltage
5 VDC 15 mA 5 VDC ± 5 %
12 VDC 12 VDC ± 5 %
24 VDC 24 VDC ± 5 %

Characteristics

Item Pushbutton Switch
Allowable
operating
frequency
Mechanical 60 operations/minute max.
Electrical 30 operations/minute max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 250 mΩ max. (initial value)
Dielectric
strength
Between terminals of same polarity 500 VAC, 50/60 Hz for 1 minute
Between terminals of different polarity 500 VAC, 50/60 Hz for 1 minute
Between each terminal and ground 1,500 VAC, 50/60 Hz for 1 minute
Between all LED terminals and all the
other terminals
500 VAC, 50/60 Hz for 1 minute
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
Shock
resistance
Malfunction 300 m/s2 max. (malfunction within 1 ms)
Durability Mechanical 1,000,000 operations min.
Electrical 200,000 operations min.
Connector holding force 40 N max.
Rated insulation voltage (Ui) 30 V (EN60947-5-1)
Electric shock protection class Class II
Degree of contamination 3 (EN60947-5-1)
Impulse
withstand
voltage
Between terminals of same polarity
Between terminals of different polarity
Between each terminal and ground
800 V (EN60947-5-1)
Conditional short-circuit current 100A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 0.1A (EN60947-5-1)
Weight Approx. 30 g
Degree of protection IP40, IP65 (Oil-proof type)
Ambient operating temperature -20 °C to 70 °C (Non-lighted type)
-20 °C to 55 °C (lighted type)
(with no icing or condensation)
Ambient operating humidity 35 % to 85 % RH
Ambient storage temperature -40 °C to 70 °C (with no icing or condensation)
Ambient storage humidity 35 % to 85 % RH

Operating Characteristics

Features A3U
Operating force (OF) max. 4.5 N
Pretravel (PT) max. 3.3 mm
Total travel (TT) max. 3.7 mm