Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

E2E (Small-diameter)

Small-diameter Proximity Sensor

E2E (Small-diameter)

Ultra small size, but surprisingly easy installation!

Size 3 dia. 4 dia. 5.4 dia.
Type Shielded Unshielded Shielded Unshielded Shielded
Model E2E-
C03SR8[]
E2E-
C03N02[]
E2E-
C04S12[]
E2E-
C04N03[]
E2E-
C05S01[]
Sensing distance
(at 23°C)
0.8 mm
±10%
2 mm
±10%
1.2 mm
±10%
3 mm
±10%
1mm
±10%
Setting distance *1
(Sensing distance × 0.7)
0 to 0.56
mm
0 to 1.4
mm
0 to 0.84
mm
0 to 2.1
mm
0 to 0.7
mm
Differential travel 15% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.)
Standard sensing
object
Iron, 3 × 3
× 1 mm
Iron, 6 × 6
× 1 mm
Iron, 4 × 4
× 1 mm
Iron, 9 × 9
× 1 mm
Iron, 5.4 × 5.4
× 1 mm
Response frequency *2 5 kHz 3.5 kHz 4 kHz 2 kHz 4 kHz
Power supply voltage *3 10 to 30 VDC (including 10% ripple (p-p))
Current consumption 10 mA max.
Control
output
*4
Load current 50 mA max. 100 mA max.
Residual
voltage
2 V max. *5
Indicators Operation indicator: Yellow (complies with European standard EN60947-5-2) Lights during output.
Operation mode B1/B2: PNP open collector, C1/C2: NPN open collector
B1/C1 models: NO, B2/C2 models: NC
Protection circuits Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Load short-circuit protection
Ambient
temperature range
Operation and storage: -25 to 70°C (with no icing or condensation)
Ambient
humidity range
Operation and storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Voltage influence ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant *6
Con-
necting
method
Pre-wired
Models
Yes Yes Yes
M8 Pre-wired
Connector
Models
Yes Yes No
M8 Connector
Models
No Yes No
Weight
(packed
state)
Pre-wired
Models
Approx.
25 g
Approx.
30 g
Approx.
35 g
Approx.
35 g
Approx.
35 g
M8 Pre-wired
Connector
Models
Approx.
20 g
Approx.
20 g
Approx.
15 g
Approx.
20 g
---
M8 Connector
Models
--- --- Approx.
10 g
Approx.
10 g
---
Materi-
als
Case SUS303 (EN 1.4305) *7 Nickelplated
brass
Sensing
surface
Heat-resistant ABS
Clamping
nuts *8
No
Toothed
washer *8
No
Cable Polyvinyl chloride (PVC)
Acces-
sories
Instruction
manual
Yes
Model label Yes
Mounting
brackets
Sold separately

Size 6.5 dia. M4 M5
Type Shielded Unshielded Shielded Unshielded Shielded Unshielded
Model E2E-
C06S02[]
E2E-
C06N04[]
E2E-
S04SR8[]
E2E-
S04N02[]
E2E-
S05S12[]
E2E-
S05N03[]
Sensing distance
(at 23°C)
2 mm
±10%
4 mm
±10%
0.8 mm
±10%
2 mm
±10%
1.2 mm
±10%
3 mm
±10%
Setting distance *1
(Sensing distance × 0.7)
0 to 1.4
mm
0 to 2.8
mm
0 to 0.56
mm
0 to 1.4
mm
0 to 0.84
mm
0 to 2.1
mm
Differential travel 15% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.)
Standard sensing
object
Iron, 6.5 × 6.5
× 1 mm
Iron, 12 × 12
× 1 mm
Iron, 3 × 3
× 1 mm
Iron, 6 × 6
× 1 mm
Iron, 4 × 4
× 1 mm
Iron, 9 × 9
× 1 mm
Response frequency *2 3 kHz 3 kHz 5 kHz 3.5 kHz 4 kHz 2 kHz
Power supply voltage *3 10 to 30 VDC (including 10% ripple (p-p))
Current consumption 10 mA max.
Control
output
*4
Load current 200 mA max.
(60 to 70°C: 100 mA)
50 mA max. 100 mA max.
Residual
voltage
2 V max. *5
Indicators Operation indicator: Yellow (complies with European standard EN60947-5-2) Lights during output.
Operation mode B1/B2: PNP open collector, C1/C2: NPN open collector
B1/C1 models: NO, B2/C2 models: NC
Protection circuits Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Load short-circuit protection
Ambient
temperature range
Operation and storage: -25 to 70°C (with no icing or condensation)
Ambient
humidity range
Operation and storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Voltage influence ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant *6
Con-
necting
method
Pre-wired
Models
Yes Yes Yes
M8 Pre-wired
Connector
Models
Yes Yes Yes
M8 Connector
Models
Yes No Yes
Weight
(packed
state)
Pre-wired
Models
Approx.
55 g
Approx.
55 g
Approx.
30 g
Approx.
30 g
Approx.
35 g
Approx.
40 g
M8 Pre-wired
Connector
Models
Approx.
20 g
Approx.
25 g
Approx.
20 g
Approx.
20 g
Approx.
20 g
Approx.
20 g
M8 Connector
Models
Approx.
10 g
Approx.
15 g
--- --- Approx.
15 g
Approx.
15 g
Materi-
als
Case SUS303 (EN 1.4305) *7
Sensing
surface
Heat-resistant ABS
Clamping
nuts *8
No SUS430 (EN 1.4016) *7
Toothed
washer *8
No SUS303 (EN 1.4305) *7
Cable Polyvinyl chloride (PVC)
Acces-
sories
Instruction
manual
Yes
Model label Yes
Mounting
brackets
Sold separately

*1. Using within the set distance enables high-speed responsiveness and a more stable repeat accuracy.
*2. The response frequency is an average value.
*3. When used at a power of 12 V, the Sensor is less susceptible to the effects of internal self heat generation and
       therefore a more stable repeat accuracy can be obtained.
*4. When the control output is 20 mA or less, the Sensor is less susceptible to the effects of internal self heat
       generation and therefore a more stable repeat accuracy can be obtained.
*5. 3 dia., M4: load current 50 mA, cable length 2 m
       4 dia., 5.4 dia., M5: load current 100 mA, cable length 2 m
       6.5 dia.: load current 200 mA, cord length 2 m
*6. Oil resistance in-house standard: Performance with respect to water insoluble oil. (Test at right)
*7. Material name in EN standards.
*8. Clamping nuts: 2 pieces, toothed washer: 1 piece

Oil resistance test

E2E (Small-diameter) Specifications 4

After the test time elapses, the characteristics below are checked for problems.
(1) Visual appearance (no damage that affects product characteristics)
(2) Operation check (ON/OFF)
(3) Insulation resistance (50 MΩ min. at 500 VDC)
(4) Dielectric strength (500 VAC, 1 min.)
(5) Water resistance (IP67)