Model | D6FZ-FGS1000 | ||
---|---|---|---|
Applicable fluid | Air or nitrogen (N2) | ||
Working pressure | 0.99MPa max. | ||
Meas-
urement |
Flow *1 | Detection range | 1 to 1,000 L/min (std) |
Resolution | 0.1 L/min | ||
Accuracy | ±2.0% of reading at 50 L/min (std) or higher *2 | ||
±0.1% F.S. at less than 50 L/min *2 | |||
Pressure | Detection range | 0 to 0.99 MPa | |
Accuracy | 2% F.S. | ||
Temper-
ature |
Detection range | -10 to 60°C | |
Accuracy | ±1.5% (absolute temperature) | ||
Resist-
ance to envi- ronment |
Operating temperature | -10 to 60°C (with no condensation or icing) | |
Operating humidity | 35% to 85% RH (with no condensation or icing) | ||
Vibration resistance
(destruction) |
10 to 55 Hz with a 0.7-mm double amplitude or acceleration of 50 m/s2 for 80
min each in X, Y, and Z directions |
||
Shock resistance
(destruction) |
150 m/s2 3 times each in six directions (up/down, left/right, forward/backward) | ||
Pressure loss | Direct piping: 10 kPa max. (0.5 MPa, at maximum flow)
Using Coupler (TL model from Nagahori Industry Co., Ltd.): 10 kPa max. (0.5 MPa, at maximum flow) |
||
Power supply voltage | For one Sensor: 16 to 24 VDC ±10%, ripple (p-p): 10% max.,
For multiple Sensors: 24 VDC ±10%, ripple (p-p): 10% max. *3 |
||
Power consumption | 2 W max. | ||
Measurement cycle | Approx. 62.5 ms | ||
Display | Display method | Status display with 2-color LED (lit or flashing) | |
Displayed contents | Presence of power, air flow, and error alarm | ||
Output | Output
interface |
Analog | Current output: 4 to 20 mA (2 outputs),*4 Maximum load resistance: 270 Ω |
ON/OFF | Open-drain output (2 outputs), *5 24 VDC 50 mA max.
ON residual voltage: 1.5 V max., OFF leakage current: 50 μA max. |
||
RS-485 | 2-wire half-duplex communications with start-stop synchronization
Baud rate: 115.2 kbps (fixed), Data bit length: 8 bits (fixed), Stop bit length: 1 bit (fixed), Parity: even (fixed), Communications protocol: Conforms to CompoWay/F. |
||
Outpus values | Momentary standard flow, total standard flow, pressure, and Sensor error output | ||
Degree of protection | IP64 (Except when switch cover is removed.) | ||
Wiring connection | M12 connector (8-pin) | ||
Connection pipe diameter | Rc1 (25 A) (Bushing enables conversion to 15 A or 20 A.) | ||
Material | Cable: PVC (polyvinylchloride); Main unit: Aluminum die-cast; Display: Acrylic | ||
Dimensions | 64 × 93 × 195 mm (W × D × H) (excluding flange) | ||
Weight (in package) | Approx. 1.2 Kg (Approx. 1.7 Kg) | ||
Accessories | Instruction Sheet |