S8EA

Switch Mode Power Supply (50, 75, 100, and 150-W Models)

S8EA

Board-type Switch Mode Power Supply with Simple Circuits That Concentrate on Basic Functions for Easy Operation Exclusive Use for 100 VAC

about this Product Family

Ratings, Characteristics, and Functions

Power rating 50 W 75 W
Output voltage 5 V 12 V 24 V 5 V 12 V 24 V
Efficiency (Typ.) 100 VAC input 78% 84% 85% 83% 85% 88%
Input Voltage *1 100 to 120 VAC
(allowable voltage: 85 to 132 VAC, 120 to 175 VDC *6)
Frequency *1 50/60 Hz (47 to 63 Hz)
Current (Typ.) 100 VAC input 1.3 A 1.4 A 1.6 A
Power factor ---
Harmonic current emissions ---
Leakage current 100 VAC input 0.5 mA max. (model with low leakage current: 0.1 mA max.)
Inrush current 100 VAC input 17.5 A max.
Output Voltage adjustment range *2 ±10% (with V. ADJ)
Ripple *3 150 mV
max.
240 mV
max.
480 mV
max.
150 mV
max.
240 mV
max.
480 mV
max.
Input variation influence ±1% max. (with 100 VAC input
at 100% load)
±1% max. (with 100 VAC input
at 100% load)
Load variation influence 2% max. 1.5% max. 2% max. 1.5% max.
Temperature variation influence 0.05%/°C max.
Startup time (Typ.) 100 VAC input 400 ms 550 ms
Hold time (Typ.) 100 VAC input 20 ms 25 ms
Additional
functions
Overload protection 105% to 160% of rated load current, voltage drop, intermittent,
automatic reset
Overvoltage protection *4 Yes (at 130% or higher of rated output)
Series operation Yes (For up to two Power Supplies; external diodes required.)
Parallel operation No
Other Ambient operating temperature -10 to 60°C (Derating is required according to the temperature.)
(with no icing or condensation)
Storage temperature -25 to 75°C
Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current:
10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10
mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20
mA)
Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE)
Vibration resistance 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions
Shock resistance 196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions
Conducted emissions Conforms to EN 55011 Group 1 Class B *7 *8
Radiated emissions Conforms to EN 55011 Group 1 Class B *7 *8
Approved standards UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN 50178 and EN 60950-1
SEMI ---
Weight *5 140 g max. (without chassis
and cover)
190 g max. (without chassis
and cover)

Power rating 100 W 150 W
Output voltage 5 V 12 V 24 V 5 V 12 V 24 V
Efficiency (Typ.) 100 VAC input 79% 85% 83% 81% 85% 87%
Input Voltage *1 100 to 120 VAC
(allowable voltage: 85 to 132 VAC, 120 to 175 VDC *6)
Frequency *1 50/60 Hz (47 to 63 Hz)
Current (Typ.) 100 VAC input 2.1A 3.3A
Power factor ---
Harmonic current emissions ---
Leakage current 100 VAC input 0.5 mA max. (model with low leakage current: 0.1 mA max.)
Inrush current 100 VAC input 17.5 A max.
Output Voltage adjustment range *2 ±10% (with V. ADJ)
Ripple *3 150 mV
max.
240 mV
max.
480 mV
max.
150 mV
max.
240 mV
max.
480 mV
max.
Input variation influence ±1% max. (with 85 to 132 VAC input at 100% load)
Load variation influence 2% max. 1.5% max. 2% max. 1.5% max.
Temperature variation influence 0.05%/°C max.
Startup time (Typ.) 100 VAC input 550 ms 350 ms
Hold time (Typ.) 100 VAC input 20 ms 25 ms
Additional
functions
Overload protection 105% to 160% of rated load current, voltage drop, intermittent,
automatic reset
Overvoltage protection *4 Yes (at 130% or higher of rated output)
Series operation Yes (For up to two Power Supplies; external diodes required.)
Parallel operation No
Other Ambient operating temperature -10 to 60°C (Derating is
required according to the
temperature.) (with no icing or
condensation)
5 V: -10 to 60°C (Derating is
required according to the
temperature.)
12/24 V: -10 to 70°C
(Derating is required according
to the temperature.)
(with no icing or condensation)
Storage temperature -25 to 75°C
Ambient operating humidity 25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current:
10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10
mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20
mA)
Insulation resistance 100 MΩ min. (between all outputs and all inputs/PE)
Vibration resistance 10 to 55 Hz, 19.6 m/s2 (2 G) for 1 h each in X, Y, and Z directions
Shock resistance 196.1 m/s2, 3 times each in ±X, ±Y, ±Z directions
Conducted emissions Conforms to EN 55011 Group 1 Class B *7 *8
Radiated emissions Conforms to EN 55011 Group 1 Class B *7 *8
Approved standards UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN 50178 and EN 60950-1
SEMI ---
Weight *5 250 g max. (without chassis
and cover)
320 g max. (without chassis
and cover)