Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

E52 (Exclusive Models)

Temperature Sensor (Exclusive Models)

E52 (Exclusive Models)

Thermocouples for Molding Machines, Thermocouples with Crimp Terminals, Surface Temperature Measurement, Room Temperature Measurement, Waterproof Platinum Resistance Thermometers, Corrosion-resistant Models, Pressure-resistant Explosion-proof Models and Double-element Models

about this Product Family

Exclusive Models

Thermocouples

Thermocouples for Molding Machines

E52-CA2GVY, E52-IC2GVY

Element type K (CA), J (IC)
Element diameter 1.0 mm (single wire)
Class Class 2 (0.75)
Protective tubing material SUS304
Thermal contact Grounded type
Temperature range 0°C to 350°C
Lead wire Glass-covered stainless steel shielded thermocouple wire with 4 dia.
1/1.0
0°C to 180°C

Thermocouples with Crimp Terminals

E52-CA1GTY, E52-IC1GTY

Element type K (CA), J (IC)
Element diameter 0.65 mm (single wire)
Class Class 2 (0.75)
Thermal contact Grounded type
Temperature range 0°C to 300°C
Lead wire Glass-covered stainless steel shielded thermocouple wire with 4 dia.
1/1.0
0°C to 150°C
Terminal shape Y-type crimp terminal for M3.5

Note: The E52-CA1GTY is also available with double elements.

Platinum Resistance Thermometers

Platinum Resistance Thermometers for Surface Temperature Measurement

E52-P2GSY

Element type Pt100
Class Class B
Protective tubing material SUS304
With brass-nickel-plated bracket
Conductor type 3-conductor system
Temperature range -50°C to 250°C
Lead wire Silicone-covered 3-conductor cable and approx. 3.9 dia.
30/0.08
-50°C to 150°C

Platinum Resistance Thermometers for Room Temperature Measurement

E52-P10GRY

Element type Pt100
Class Class B
Protective tubing material SUS304
Conductor type 3-conductor system
Temperature range -50°C to 60°C
Lead wire Vinyl-covered 3-conductor cable with 6.1 dia.
20/0.18
-25°C to 60°C

Waterproof Platinum Resistance Thermometers

E52-P10GPY

Element type Pt100
Class Class B
Protective tubing material SUS304
Conductor type 3-conductor system
Temperature range 0°C to 70°C (underwater)
-20°C to 70°C (in the air)
Lead wire Vinyl-covered 3-conductor cable with 6.1 dia.
12/0.18
-25°C to 60°C
Resistive pressure 981 kps

Corrosion-resistant Models with Fluororesin-covered Protective Tubing

Thermocouples

Exposed-lead Models

E52-CA20AY-1

Element type K (CA)
Class Class 2 (0.75)
Protective tubing material ASTM316L with Fluororesin-covered (FEP) tube
Thermal contact Non-grounded type
Temperature range 0°C to 180°C
Lead wire Vinyl-covered: -20°C to 70°C

Platinum Measurement

Exposed-lead Models

E52-P20AY-1

Element type Pt100
Class Class B
Protective tubing material SUS316 with Fluororesin-covered (FEP) tube
Conductor type 3-conductor system
Temperature range -80°C to 180°C
Lead wire Vinyl-covered: -20°C to 70°C

FEP-molded Models (Completely Waterproof)

E52-P5AY-40

Element type Pt100
Class Class B
Protective tubing material Fluororesin (FEP) tube (element/fluororesin mold (FEP))
Conductor type 3-conductor system
Temperature range -50°C to 180°C
Lead wire Fluororesin (FEP) cover (with outer cover): -50°C to 180°C

Pressure-resistant Explosion-proof (IICT6) Models

Thermocouples

Enclosed-terminal Models

E52-CA[][]C-N-6

Element type K (CA)
Class Class 2 (0.75)
Class 3 (Level 1.5) at -40°C and under
Protective tubing material L2 section: ASTM316L
L1 section: SUS304
Explosionproof
specifications
Construction Pressure-resistant explosion-proof structure
Explosion-protected
class and ignitability
IICT6
Explosion-proof
temperature range
-20°C to 85°C
Lead wire wiring method Pressure-resistant packing cable ground type
Conduit thread G1/2
Installation method Conforms to Technical Recommendations of the
Research Institute of Industrial Safety (Japan)

Platinum Resistance Thermometers for Surface Temperature Measurement

Enclosed-terminal Models

E52-P[][]C-N-6

Element type Pt100
Class Class B
Protective tubing material L2 section: ASTM316L
L1 section: SUS304
Explosionproof
specifications
Construction Pressure-resistant explosion-proof structure
Explosion-protected
class and ignitability
IICT6
Explosion-proof
temperature range
-20°C to 85°C
Lead wire wiring method Pressure-resistant packing cable ground type
Conduit thread G1/2
Installation method Conforms to Technical Recommendations of the
Research Institute of Industrial Safety (Japan)

Double-element Models

Thermocouple

Exposed-lead Models

E52-CA20AY-7

Element type K (CA)
Class Class 2 (0.75)
Protective tubing material ASTM316L (with sheath)
Thermal contact Non-grounded type
Temperature range 0°C to permissible temperature limit
Lead wire Vinyl-covered with external dimensions of 2.4 x 4.1
7/0.3
-20°C to 70°C

Permissible Temperature in Dry Air

D Element wire
K (CA)
ASTM316L
3.2 dia. 750°C
4.8 dia. 800°C
6.4 dia. 800°C
8.0 dia. 900°C

Platinum Resistance Thermometers

Exposed-lead Models

E52-P20AY-7

Element type Pt100
Class Class B
Protective tubing material ASTM316L (with sheath)
Conductor type 3-conductor system
Temperature range -200°C to 450°C
Lead wire Vinyl-covered with 6.5 dia.
19/0.18
-20°C to 70°C

Enclosed-terminal Models

E52-P20C-N-7

Element type Pt100
Class Class B
Protective tubing material ASTM316L (with sheath)
Conductor type 3-conductor system
Temperature range -200°C to 450°C

Silicone-covered Lead Wires Models

Thermocouples

Exposed-lead Models with Screws

E52-CA1DY-40

Element type K (CA)
Class Class 2 (0.75)
Screw material SUS304
Thermal contact Grounded type
Temperature range 0°C to 300°C
Lead wire Silicone-covered with external dimensions of 3.5 x 4.9
30/0.1
0°C to 150°C
Terminal shape Y-type crimp terminal for M3.5

Note: Refer to the installation example for the E52-CA1DY.

Thermocouples with Crimp Terminals

E52-CA1GTY-14

Element type K (CA)
Class Class 2 (0.75)
Thermal contact Grounded type
Temperature range 0°C to 200°C
Lead wire Silicone-covered compensating cable with external dimensions of 3.2 x 4.6
30/0.1
0°C to 150°C
Terminal shape Y-type crimp terminal for M3.5