Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

E32-LT / LD

Fiber Unit Build-in Lens Series

E32-LT / LD

High-power, Stable Detection. Is the Standard for the Future!

about this Product Family

Through-beam Fiber Units

Type Appearance
(mm)
Bending
radius
of cable
Sensing distance (mm) Optical
axis
diameter
(minimum
sensing
object)
Models
Sensing
direction
Aperture
angle
E3X-HD E3NX-FA
Top-view 15°
3128_lu_1_1

IP50
R25 GIGA: 4,000 *
HS: 2,700
ST: 4,000 *
SHS: 1,080
GIGA: 4,000 *
HS: 4,000 *
ST: 4,000 *
SHS: 1,080
2.3 dia.
(0.1 dia./
0.03 dia.)
E32-LT11 2M
Flexible,
R1
GIGA: 4,000 *
HS: 2,300
ST: 3,500
SHS: 920
GIGA: 4,000 *
HS: 3,450
ST: 4,000 *
SHS: 920
E32-LT11R 2M

* The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1.The following mode names and response times apply to the modes given in the Sensing distance column.
             [E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
             and SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
             [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
             and SHS: Super-high-speed mode (30 μs)
Note 2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
              with the sensing distance and sensitivity set to the optimum values.
             The first value is for the E3X-HD and the second value is for the E3NX-FA.

Reflective Fiber Units

Type Appearance
(mm)
Bending
radius
of cable
Sensing distance (mm) Optical
axis
diameter
(minimum
sensing
object)
Models
Sensing
direction
Aperture
angle
E3X-HD E3NX-FA
Top-view 15°
3128_lu_2_1

IP50
R25 GIGA: 860
HS: 250
ST: 360
SHS: 110
GIGA: 1,290
HS: 370
ST: 540
SHS: 110
(0.1 dia./
0.03 dia.)
E32-LD11 2M
Flexible,
R1
GIGA: 840
HS: 240
ST: 350
SHS: 100
GIGA: 1,260
HS: 360
ST: 520
SHS: 100
E32-LD11R 2M

Note 1.The following mode names and response times apply to the modes given in the Sensing distance column.
             [E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
             and SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
             [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
             and SHS: Super-high-speed mode (30 μs)
Note 2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
             with the sensing distance and sensitivity set to the optimum values.
             The first value is for the E3X-HD and the second value is for the E3NX-FA.
Note 3. The sensing distances for Reflective Fiber Units are for glossy white paper.