Model | NPN output | ZX1-LD50A61
ZX1-LD50A66 |
ZX1-LD100A61
ZX1-LD100A66 |
ZX1-LD300A61
ZX1-LD300A66 |
ZX1-LD600A61
ZX1-LD600A66 |
---|---|---|---|---|---|
PNP output | ZX1-LD50A81
ZX1-LD50A86 |
ZX1-LD100A81
ZX1-LD100A86 |
ZX1-LD300A81
ZX1-LD300A86 |
ZX1-LD600A81
ZX1-LD600A86 |
|
Measurement range | 50 ± 10 mm | 100 ± 35 mm | 300 ± 150 mm | 600 ± 400 mm | |
Light source (wave length) | Visible-light semiconductor laser
(wavelength: 660 nm, 1 mW max., IEC/EN Class 2, FDA Class 2 *1) |
||||
Spot diameter (typical)
(Defined at the measurement center distance) *2 |
0.17 mm dia. | 0.33 mm dia. | 0.52 mm dia. | 0.56 mm dia. | |
Power consumption | 2,500 mW max. (105 mA max. at 24 VDC, 210 mA max. at 12 VDC) | ||||
Current consumption | 250 mA max. (at power supply voltage 10 VDC) | ||||
Control output | Load power supply voltage: 30 VDC max., Load current: 100 mA max.
(Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to 100 mA)) |
||||
Analog output | Current output: 4 to 20 mA, maximum load resistance: 300 Ω
(The output is 20 mA for the nearest point in the measurement range in respect to the Sensor and 4 mA for the farthest point.) |
||||
Functions | Smart tuning, keep function, background removal, OFF-delay timer, ON-delay
timer, one-shot timer, ON/OFF-delay timer, zero reset, area output, eco function, hysteresis width setting, and setting initialization |
||||
Indicators | Digital display (red), output indicator (OUT1, OUT2) (orange), zero reset indicator
(orange), menu indicator (orange), laser ON indicator (green), and smart tuning indicator (blue) |
||||
Response
time |
Judgment output | Super-high-speed (SHS) Mode: 1 ms
High-speed (HS) Mode: 10 ms Standard (Stnd) Mode: 100 ms |
|||
Laser OFF input | 200 ms max. | ||||
Zero reset input | 200 ms max. | ||||
Temperature characteristic *3 | 0.03% F.S./°C | 0.04% F.S./°C | |||
Linearity *4 | ±0.15% F.S. | ±0.25% F.S. | ±0.25% F.S.
(200 to 600 mm) ±0.5% F.S. (entire range) |
||
Resolution *5 | 2 μm | 7 μm | 30 μm | 80 μm | |
Ambient illumination | Illumination on received light surface:
7,500 lx or less (incandescent light) |
Illumination on received light surface:
5,000 lx or less (incandescent light) |
|||
Ambient temperature | Operating: -10 to +55°C, Storage: -15 to +70°C (with no icing or condensation) | ||||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz, 1 minute | ||||
Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions | ||||
Shock resistance (destruction) | 500 m/s2 3 times each in X, Y, and Z directions | ||||
Degree of protection *6 | IEC 60529, IP67 | ||||
Connection method *7 | Pre-wired model (Standard cable length: 2 m, 5 m)
Pre-wired connector model (Standard cable length: 0.5 m) |
||||
Weight
(packed state/ sensor only) |
Pre-wired models (2 m) | Approx. 240 g/Approx. 180 g | Approx. 270 g/Approx. 210 g | ||
Pre-wired models (5 m) | Approx. 450 g/Approx. 330 g | Approx. 480 g/Approx. 360 g | |||
Pre-wired connector
models (0.5 m) |
Approx. 170 g/Approx. 110 g | Approx. 200 g/Approx. 140 g | |||
Materials | Case and cover: PBT (polybutylene terephthalate), Optical window: Glass, Cable:
PVC, Mounting hole part: SUS303 |
||||
Accessories | Instruction sheet and Laser warning label (English) |