Model ZX2-LD50L ZX2-LD50 ZX2-LD100L ZX2-LD100
Optical system Diffuse reflective
Light source
(wave length)
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 1mW max.
EN class 2, FDA class 2 *5
Measurement center
point
50 mm 100 mm
Measurement range ±10 mm ±35 mm
Beam shape Line Spot Line Spot
Beam size *1 Approx. 60 μm ×
2.6 mm
Approx. 60 μm dia. Approx.110 μm ×
2.7 mm
Approx.110 μm dia.
Resolution *2 1.5μm 5μm
Linearity *3 ±0.05% F.S.
(40 to 50 mm)
±0.1% F.S.
(40 to 50 mm)
±0.05% F.S.
(65 to 100 mm)
±0.1% F.S.
(65 to 100 mm)
Temperature
characteristic *4
0.02% F.S./°C
Ambient illumination Incandescent lamp: 10,000 lx max. (on light receiving side)
Ambient temperature Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min.
Vibration resistance
(destruction)
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions
Shock resistance
(destruction)
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Degree of protection IEC60529, IP67
Connection method Connector connection (standard cable length: 500 mm)
Weight (packed state) Approx. 160 g (main unit only: Approx. 75 g)
Materials Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Internal thread: Brass, Cable: PVC
Accessories Instruction sheet, Ferrite core ×1 (made by TDK Corp. ZCAT1730-0730A), Laser warning
label (English), FDA

Regular-reflective Sensor Head

Model ZX2-LD50L
Optical system Regular reflective
Light source (wave length) Visible-light semiconductor laser with a wavelength of 660 nm and an output of 0.24
mW max. EN class 1, FDA class 1 *5
Measurement center point 48 mm
Measurement range ±5 mm
Beam shape Spot
Beam size *1 Approx. 60 μm dia.
Resolution *2 1.5 μm
Linearity *3 ±0.3%F.S. (entire range)
Temperature
characteristic *4
0.06%F.S./°C
Ambient illumination Incandescent lamp: 10,000lx max. (on light receiving side)
Ambient temperature Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute
Vibration resistance
(destruction)
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes, each in X,Y,and Z directions
Shock resistance
(destruction)
300 m/s2 3 times each in six directions (up/down,left/right,forward/backward)
Degree of protection IEC 60529, IP67
Connection method Connector connection (standard cable length: 500 mm)
Weight (packed state) Approx.160g (Sensor Head only: Approx.75g)
Materials Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Internal thread: Brass, Cable: PVC
Accessories Instruction sheet, Ferrite core ×1 (made by TDK Corp. ZCAT1730-0730A), Laser
warning label (English), FDA

Note: False detection outside the measurement range can occur in the case of an object with high reflectance.
*1. Beam size: Defined as 1/e2 (13.5 %) of the center optical intensity at the minimum value of the measurement
       range (effective value).
       False detections can occur in the case there is light leakage outside the defined region and the surroundings of the
       target object have a high reflectance in comparison to the target object. Correct measurements may not be
       obtained if the workpiece is smaller than the beam size.
*2. Resolution: indicates the degree of fluctuation (±3σ) of analog output when connected to the ZX2-LDA.
       (The measured value is given for the center distance for OMRON’s standard target object (diffuse-reflective models:
       white ceramic object, regular-reflective models:1/4 λ flat mirror) when the response time of the ZX2-LDA is set to
       128 ms.)
       Indicates the repetition accuracy for when the workpiece is in a state of rest. Not an indication of distance accuracy.
       Resolution performance may not be satisfied in a strong electromagnetic field.
*3. Linearity: indicates the error with respect to the ideal straight line of the displacement output in the case of
       measuring Omron's standard target object. Linearity and measured value may vary depending on target object.
       F.S. indicates the full scope of the measurement range. (ZX2-LD50(L): 20 mm)
*4. Temperature characteristic: Value for the case the space between the sensor head and Omron’ s standard target
       object is secured by an aluminum jig. (Measured at the measurement center distance)
*5. These Sensors are classified as Class 2 laser devices for diffuse-reflective models and Class 1 for regular-reflective
       models under IEC 60825-1 and the regulations of Laser Notice No. 50 for FDA certification. CDRH registration has
       been completed.

Amplifier Units

Model ZX2-LDA11 ZX2-LDA41
Measurement period *1 Min. 30 μs
Response time 60 μs, 120 μs, 240 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms, 12 ms, 20 ms, 36 ms, 66 ms,
128 ms, 250 ms, 500ms
Analog output *2 4 to 20 mA, Max. load resistance: 300Ω/±5 VDC or 1 to 5 VDC, Output impedance: 100Ω
Judgement outputs
(HIGH/PASS/LOW: 3
outputs), error output
NPN open-collector outputs, 30 VDC, 50
mA max. (residual voltage: 1 V max. for load
current 10 mA max., 2V max. for load
current above 10 mA)
PNP open-collector outputs, 30 VDC, 50
mA max. (residual voltage: 1 V max. for load
current 10 mA max., 2 V max. for load
current above 10 mA)
Laser OFF input, zero
reset input, timing input,
reset input, bank input
ON: Short-circuited with 0-V terminal or
1.2 V or less
OFF: Open (leakage current: 0.1 mA max.)
ON: Supply voltage short-circuited or supply
voltage within -1.2 V
OFF: Open (leakage current: 0.1 mA max.)
Functions Smart tuning, scaling, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak
hold, self-bottom hold, average hold, zero reset, On-delay timer, OFF-delay timer, keep/
clamp switch, (A-B) calculations *3, thickness calculation *3, mutual interference
prevention *3, laser deterioration detection, bank function (4 banks), differential function
Indications Judgement indicators: HIGH (orange), PASS (green), LOW (orange), 11-segment main
display (red), 11-segment sub-display (orange), laser ON (green), zero reset (green),
enable (green), menu (green), HIGH threshold (orange), LOW threshold (orange)
Power supply voltage 10 to 30 VDC, including 10% ripple (p-p)
Power consumption 3,000 mW max. (at 24 VDC: 125 mA max., at 12 VDC: 250 mA max.)
Ambient temperature Operating: 0 to 50 °C, Storage: -15 to 70 °C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min.
Vibration resistance
(destruction)
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X, Y, and Z directions
Shock resistance
(destruction)
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Degree of protection IEC60529, IP40
Connection method Prewired (standard cable length: 2 m)
Weight (packed state) Approx. 200 g (main unit only: Approx. 135 g)
Materials Case: PBT (polybutylene terephtahalate), Cover: Polycarbonate, Display: Methacrylic resin,
Button: Polyacetal, Cable: PVC
Accessories Instruction sheet

*1. In the case of Omron’s standard target object (white ceramic)
*2. Select current output (4 to 20 mA) and voltage output (±5V or 1 to 5V) by MENU mode.
*3. Calculating unit (ZX2-CAL) is necessary. Calculations are possible for up to two amplifier units. Mutual interference
      prevention is possible for up to five amplifier units.

Calculating Unit

Model ZX2-CAL
Applicable Amplifier Units ZX2-LDA11, ZX2-LDA41
Current consumption 12 mA max. (supplied from the Smart Sensor Amplifier Unit)
Ambient temperature Operating: 0 to +50°C, storage: -15 to +70°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Connection method Connector
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute
Vibration resistance (destruction) 10 to 150 Hz, 0.7-mm double amplitude, 80 minutes, each in X,Y,and Z directions
Shock resistance (destruction) 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Materials Case: ABS, Display: Methacrylic resin
Weight (packed state) Approx. 50g (Calculating Unit only: Approx. 15g)
Accessories Instruction sheet

ZX2-series Communications Interface Unit

Model ZX2-SF11
Power supply voltage 10 to 30 V DC ±10% (including 10% ripple (p-p))
(Supplied from Sensor Amplifier.)
Power consumption 720 mW max. (at 24 V: 30 mA max., at 12 V: 60 mA max.)
(Not including Sensor Amplifier current consumption or output current
Applicable Amplifier Units ZX2-LDA[][] (Production after November 2013)
Applicable Amplifier
Unit versions
Sensor Amplifier Unit version: V1.330 or higher
(The Sensor Amplifier version is shown on the sub-digital
display when the power of the Sensor Amplifier is turned ON.)
Max. No. of Amplifier
Units
5
Commu-
nications
functions
Port RS-232C (9-pin, D-Sub connector)
Communications method Full duplex
Synchronization method Start/stop synchronization
Transmission code ASCII
Baud rate 38,400 (at shipping)/9,600 bps switchable
Data bit length 8 bits
Parity check None
Stop bit length 1 bit
Data
delimiter
Receiving CR or CR + LF is automatically recognized.
Sending CR + LF fixed
Indicators Power supply: green, Sensor communications: green, Sensor
communications error: red, External terminal communications:
green, External terminal communications error: red
Protective circuits Power supply reverse polarity protection
Ambient temperature Operating: 0 to 50°C, storage: -15 to 60°C
(with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85%
(with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min,
Leakage current: 10 mA max.
Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories Instruction sheet, 2 clamps