Page top

Building Automation


Industrial Automation


Power Automation & Safety

Bangladesh Distributor

DZ

Special-purpose Basic Switch

DZ

DPDT Basic Switch for Two Independent Circuit Control

Ratings

Rated voltage Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
10
10
2
1.5
1
0.7
6
4
3
2
1.5
1
8 VDC
14 VDC
30 VDC
125 VAC
250 VDC
10
10
10
0.5
0.25
3
3
3
1.5
1.5
1.5
6
6
4
0.05
0.03
5
5
3
2.5
2.5
1.5
0.5
0.25
0.05
0.03

Note: 1. The above values are for steady-state current.
           2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
           3. Lamp load has an inrush current of 10 times the steady-state current.
           4. Motor load has an inrush current of 6 times the steady-state current.
           5. The ratings values apply under the following test conditions:
                (1) Ambient temperature: 20±2°C
                (2) Ambient humidity: 65±5%RH
                (3) Operating frequency: 20 operations/min

Characteristics

Operating speed 0.1 mm to 1 m/s *1
Operating frequency Mechanical 240 operations/min
Electrical 20 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal part, and between current-carrying metal part and ground and between switches
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude *2
Shock resistance Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max. *1 *2
Durability Mechanical 1,000,000 operations min.
Electrical 500,000 operations min.
Degree of protection IP00
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -25°C to 80°C (with no icing)
Ambient operating humidity 35% to 85%RH
Weight Approx. 30 to 50 g

*1. The values are for pin plunger models. (Contact your OMRON representative for other models.)
*2. Malfunction: 1 ms max.

Contact Specifications

Contacts Material Silver alloy
Gap (standard value) 0.5 mm
Inrush current NC 30 A max.
NO 15 A max.