H7CX-A

Multifunction Preset Counter

H7CX-A

DIN 48 × 48 mm Multifunction Preset Counter with a Bright, Easy-to-view, Negative Transmissive LCD

about this Product Family

Ratings

Models H7CX-A114[]-N H7CX-A11[]-N H7CX-A4[]-N
Classification Preset counter
Configuration 1-stage preset counter, 1-stage preset counter with total counter (selectable) *1
Ratings Power supply
voltage*2
100 to 240 VAC, 50/60 Hz
24 VAC, 50/60 Hz or 12 to 24 VDC
100 to 240 VAC, 50/60 Hz
12 to 24 VDC
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Power
consumption
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx.
3.7 W at 12 to 24 VDC
Mounting method Flush mounting or surface mounting Flush mounting
External connections 11-pin socket Screw terminals
Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29
Waterproof Packing is used.
Input signals CP1, CP2, reset, and total reset
Counter Maximum
counting speed
30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms)
(selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Input mode Increment, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN
B (individual inputs), or UP/DOWN C (quadrature inputs))
Output mode N, F, C, R, K-1, P, Q, A, K-2, D, and L.
One-shot output
time
0.01 to 99.99 s
Reset system External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and
automatic reset (internal according to C, R, P, and Q mode operation)
Tachometer Refer to the separate table for tachometer function ratings.
Prescaling function Yes (0.001 to 9.999) Yes (0.001 to 99.999) Yes (0.001 to 9.999)
Decimal point adjustment Yes (rightmost 3 digits)
Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during sensor
waiting time.)
Input method No-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
No-voltage input/voltage input (selectable)
External power supply 12 VDC (±10%), 100 mA (except for H7CX-A[]D models) Refer to on page for details.
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load:
10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC
max. (approx. 1 V), Leakage current: 0.1 mA max.
Display*3 7-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
Digits 4 digits
-999 to 9999
(-3 digits to +4 digits)
6 digits
-99999 to 999999
(-5 digits to +6 digits)
4 digits
-999 to 9999
(-3 digits to +4 digits)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature
range
-10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no
icing or condensation)
Storage temperature range -25 to 70°C (with no icing or condensation)
Operating humidity range 25% to 85%
Case color Black (N1.5) (Optional Front Panels are available to change the Front Panel color to light
gray or white.)
Attachments --- Flush mounting adapter,
waterproof packing,
terminal cover

Models H7CX-A[]-N H7CX-A4W[]-N H7CX-AW[]-N/-AU[]-N
Classification Preset counter Preset counter/tachometer
Configuration 1-stage preset counter,
1-stage preset counter with
total counter (selectable) *1
1-stage/2-stage preset
counter, total and preset
counter *1, batch counter,
dual counter, and twin
counter (selectable)
1-stage/2-stage preset
counter, total and preset
counter *1, batch counter,
dual counter, twin counter,
and tachometer (selectable)
Ratings Power supply
voltage*2
100 to 240 VAC, 50/60 Hz
12 to 24 VDC
100 to 240 VAC at 50/60 Hz
24 VAC at 50/60 Hz or 12 to
24 VDC
12 to 24 VDC
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Power
consumption
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx.
3.7 W at 12 to 24 VDC
Mounting method Flush mounting
External connections Screw terminals
Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29
Waterproof Packing is used.
Input signals CP1, CP2, reset, and total
reset
CP1, CP2, reset 1, and reset 2
Counter Maximum
counting speed
30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms)
(selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Input mode Increment, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN
B (individual inputs), or UP/DOWN C (quadrature inputs))
Output mode N, F, C, R, K-1, P, Q, A, K-2,
D, and L.
N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.
One-shot output
time
0.01 to 99.99 s
Reset system External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and
automatic reset (internal according to C, R, P, and Q mode operation)
Tachometer Refer to the separate table for tachometer function ratings.
Prescaling function Yes (0.001 to 99.999) Yes (0.001 to 9.999) Yes (0.001 to 99.999)
Decimal point adjustment Yes (rightmost 3 digits)
Sensor waiting time 290 ms max. (Control output is turned OFF and no input is accepted during sensor
waiting time.)
Input method No-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
No-voltage input/voltage input (selectable)
External power supply 12 VDC (±10%), 100 mA (except for H7CX-A[]D models) Refer to on page for details.
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load:
10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC
max. (approx. 1 V), Leakage current: 0.1 mA max.
Display*3 7-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
Digits 6 digits
-99999 to 999999
(-5 digits to +6 digits)
4 digits
-999 to 9999
(-3 digits to +4 digits)
6 digits
-99999 to 999999
(-5 digits to +6 digits),
tachometer: 0 to 999999
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature
range
-10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no
icing or condensation)
Storage temperature range -25 to 70°C (with no icing or condensation)
Operating humidity range 25% to 85%
Case color Black (N1.5) (Optional Front Panels are available to change the Front Panel color to light
gray or white.)
Attachments Flush mounting adapter, waterproof packing, terminal
cover
Flush mounting adapter,
waterproof packing,
terminal cover, label for
DIP switch settings

*1. 1-stage preset counter and total counter functionality.
*2. Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power.
*3. The display is lit only when the power is ON. Nothing is displayed when power is OFF.

Tachometer Function Ratings

Model H7CX-A114[]-N
H7CX-A11[]-N
H7CX-A4[]-N
H7CX-A[]-N
H7CX-A4W[]-N
H7CX-AW[]-N/-AU[]-N
Input mode No tachometer
functionality
Selectable from independent measurements for 1 or 2 inputs, differential input
for 2 inputs, absolute ratio for 2 inputs, and error ratio for 2 inputs.
Pulse
measurement
method
Periodic measurement Pulse width measurement
Maximum
counting
speed
30 Hz
(minimum
pulse width:
16.7 ms)
1-input mode: 10 kHz
(minimum pulse width:
0.05 ms)
Other modes: 5 kHz
(minimum pulse width:
0.1 ms)
30 Hz
(minimum
pulse
width:
16.7 ms)
1-input mode: 10 kHz
(minimum pulse width:
0.05 ms)
Other modes: 5 kHz
(minimum pulse width:
0.1 ms)
Minimum input
signal width
--- --- 30 ms *1 1-input mode: 0.2 ms
Other modes: 0.4 ms *
Measuring
ranges
0.001 to
30.00 Hz
1-input mode: 0.001 to 10
kHz,
Other modes: 0.01 to 5
kHz
0.030 to
999999 s
1-input mode: 0.0002 to
99999 s
Other modes: 0.0004 to
99999 s
Sampling period 200 ms min. 200 ms min. or continuous
selectable (minimum
interval of 10 ms)
Continuous (minimum interval of 10
ms)
Measuring
accuracy
±0.1% FS ±1 digit max. (at 23 ±5°C)
Output mode Input mode:
Not 2-input independent measurement: HI-LO, AREA, HI-HI, LO-LO
2-input independent measurement: HI-HI, LO-LO
Auto-zero time 0.1 to 999.9s
Startup time 0.0 to 99.9s
Averaging Simple averaging/moving averaging selectable, Processing: OFF, 2, 4, 8, or 16
times
Hold input Minimum input signal width: 20 ms
* An input OFF time of at least 20 ms is required.

Characteristics

Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying terminals and exposed non-current-
carrying metal parts, and between non-continuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-
carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuit for all models
except H7CX-[]D[] (1,000 VAC for 24 VAC/12 to 24 VDC)
1,000 VAC (for H7CX-[]SD[]), 50/60 Hz for 1 min between control output, power supply,
and input circuit (2,000 VAC for models other than H7CX-[]SD[])
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage 3.0 kV between power terminals (1.0 kV for models with 24 VAC/12 to 24 VDC or 12 to 24
VDC)
4.5 kV between current-carrying terminals and exposed non-current-carrying metal parts
(1.5 kV for models with 24 VAC/12 to 24 VDC or 12 to 24 VDC)
Noise immunity ±1.5 kV between power terminals (±480 V for models with 12 to 24 VDC) ±600 V
between input terminals Square-wave noise by noise simulator (pulse width: 100 ns/1 μs,
1-ns rise)
Static immunity Malfunction: 8 kV Destruction: 15 kV
Vibration
resistance
Destruction 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each
Malfunction 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each
Shock
re-sistance
Destruction 300 m/s2 each in three directions
Malfunction 100 m/s2 each in three directions
Life expectancy Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature
condition: 23°C) *
Weight Approx. 130 g (Counter only)
* Refer to the Life-test Curve.

Life-test Curve (Reference Values)

Resistive load

H7CX-A Specifications 7

Inductive load

H7CX-A Specifications 8

A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases, a life of 100,000 operations can be expected.

Applicable Standards

Approved
safety
standards
cULus (or cURus): UL508/CSA C22.2 No. 14 *1
EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II
B300 PILOT DUTY
1/4 HP 120 VAC, 1/3 HP, 240 VAC, 3 A resistive load
VDE0106/P100 (finger protection)
EMC (EMI) EN61326-1 *2
Emission Enclosure: EN 55011 Group 1 class A
Emission AC mains: EN 55011 Group 1 class A
(EMS) EN61326-1 *2
Immunity ESD: EN 61000-4-2: 4 kV contact discharge; 8 kV air discharge
Immunity RF-interference: EN 61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz); 10 V/m (Pulse-
modulated, 900 MHz ±5 MHz)
Immunity Conducted Disturbance: EN 61000-4-6: 10 V (0.15 to 80 MHz)
Immunity Burst: EN 61000-4-4: 2 kV power-line; 1 kV I/O signal-line
Immunity Surge: EN 61000-4-5: 1 kV line to lines (power and output lines); 2 kV line to ground (power and
output lines)
Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage)

*1. The following safety standards apply to models with sockets (H7CX-A11[] or H7CX-A114[]).
     cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used.
     cUR (Recognition): Applicable when any other socket is used.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

I/O Functions

Using as a Counter *1

Inputs CP1, CP2 (1) In general (except for Dual Counter Mode)
Reads counting signals.
Increment, decrement, command, individual, and quadrature inputs accepted.
(2) When used as a dual counter or twin counter
Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.
Increment signals can be input.
Reset/reset 1 (1) In general (except for Dual Counter Mode)
Resets present value and outputs (OUT2 when using the batch counter) *2.
Counting cannot be performed during reset/reset 1 input.
Reset indicator is lit while reset input is ON.
(2) When used as a dual counter or twin counter.
Resets the CP1 present value (to 0).
Counting for CP1 input cannot be performed while the reset 1 input is ON.
The reset indicator is lit while the reset 1 input is ON.
Total reset or reset 2 The reset function depends on the selected configuration *3.
Outputs OUT1, OUT2 Outputs signals according to the specified output mode when a set value is reached.

*1. For information on operation of I/O functions, refer to Catalog.
*2. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present
       value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models.
*3. Reset operates as described in the following table. (The reset indicator will not be lit.)
Configuration Reset operation
1-stage/2-stage preset counter Does not operate (not used).
Total and preset counter Resets the total count value.
The total count value is held at 0 while the total reset input is ON.
Batch counter Resets the batch count value and batch output (OUT1).
The batch count value is held at 0 while the reset 2 input is ON.
Dual counter Resets the CP2 present value.
Counting for CP2 input cannot be performed while the reset 2 input is ON.
Twin counter Resets the CP2 present value.

• The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values)

Minimum reset signal width Output delay time
1 ms 0.8 to 1.2 ms
20 ms 15 to 25 ms

Operating Procedures (Tachometer Function)

Inputs CP1, CP2 Reads counting signals. (The CP2 input can be used when the input mode is not 1-input
mode.)
Reset/reset 1 Holds the measurement value and outputs. (The reset 2 input can be used when the input
mode is 2-input independent measurement.)
Functions as a hold input.
The measurement value (displayed value) and the outputs are held while the RST Key on the
front panel is pressed.
The reset indicator is lit when the value is being held.
Outputs OUT1, OUT2 Outputs signals according to the specified output mode when a set value is reached.