Model | ES1C | |
---|---|---|
Power supply voltage | 12 to 24 VDC | |
Operating voltage range | 90% to 110% of rated voltage | |
Current consumption | 70 mA max. | |
Measuring temperature range | 0 to 400°C | |
Measurement accuracy | 0 to 200°C: ±2°C, 201 to 400°C: ±1% PV (emissivity: 0.95) | |
Influence
of EMS |
Radiated electromagnetic
field immunity |
±10°C max. |
Imunity Conducted
Disturbance |
±10°C max. | |
Response time | 100 ms/90% | |
Reproducibility | ±1% of reading value | |
Measurement wavelength | 8 to 14 μm | |
Light-receiving element | Thermopile | |
Emissivity | 0.95 fixed | |
Current output | 4 to 20 mA DC, Load: 250 Ω max. | |
Ambient temperature range | Operating: 0 to 70°C, Storage: -20 to 70°C (with no icing or condensation) | |
Ambient humidity range | Operating and storage: 35% to 85% | |
Vibration resistance (destruction) | 1.5-mm amplitude at 10 to 55 Hz for 2 hours each in the X, Y, and Z directions | |
Weight | 180 g | |
Degree of protection | Equivalent to IP67 | |
Applicable safety standards | CE Marking * |