Type | Standard models | Ultra-long-term
APC models |
High-speed
response models |
||
---|---|---|---|---|---|
Standard models | Model for Sensor
Communications Unit |
||||
Model | E3X-DA[]-S
([]: 21/51/7/9) |
E3X-DA0-S *1 | E3X-DA[]R-S
([]: 21/51/7/9) |
E3X-DA[]F-S
([]: 21/51/7/9) |
|
Light source (wavelength) | Red,4-element LED (625 nm) | ||||
Power supply voltage | 12 to 24 VDC ± 10%, ripple (p-p) 10% max. | Supplied from the
connector through the Sensor Communications Unit |
12 to 24 VDC ±10%, ripple (p-p) 10% max. | ||
Power consumption | Normal mode: 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA
max. at 12 VDC) Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC) Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC) |
||||
Control output/APC alarm
output *1 |
Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 2 V max. |
||||
External input *2 | No-voltage input
(contact/transistor) *3 |
--- | No-voltage input
(contact/transistor) *3 |
--- | |
Protection circuits | Power supply reverse polarity protection, output short-circuit protection and output
reverse polarity protection |
||||
Re-
sponse time |
Super-high-
speed Mode *4 |
Operate or reset:
80 μs |
--- | Operate or reset:
80 μs |
NPN output:
Operate: 46 μs, Reset: 48 μs PNP output: Operate: 51 μs, Reset: 53 μs |
High-speed Mode | Operate or reset: 250 μs | --- | |||
Standard Mode | Operate or reset: 1 ms | ||||
High-resolution
Mode |
Operate or reset: 4 ms | ||||
Tough Mode | Operate or reset: 16 ms | ||||
Sensitivity setting | Teaching or manual method | ||||
Func-
tions |
Power tuning | Light emission power and reception gain, digital control method | |||
Differential
detection |
Switchable between Single-edge and Double-edge Detection
Modes. Single edge: Set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms. Double edge: Set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms |
--- | |||
Automatic power
control (APC) |
Always enabled.
High-speed control of emission current Wide-range APC for the E3X-DA[]R-S |
||||
Timer | Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay
timer |
||||
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms
increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1-s increments) |
|||||
ATC | Provided | ||||
APC margin
display |
--- | Provided | --- | ||
Slow-motion
display |
--- | Provided | |||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
Resetting
settings |
Select from initial reset (factory defaults) or user reset (saved settings). | ||||
Mutual
interference prevention |
Possible for up to 10 units *5 | --- | |||
ECO Mode *6 | Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital
display OFF). |
||||
External input
setting *2 |
Select from teaching operations, power tuning, zero reset,
emitter OFF, or ATC start. |
--- | |||
Output setting | Select from output for each channel,
area output, or self-diagnosis. |
--- | |||
Indicator | Operation indicator for channel 1 (orange)
Operation indicator for channel 2 (orange) |
Operation indicator
for channel 1 (orange) APC alarm output indicator (orange) |
Operation indicator
for channel 1 (orange) Power tuning indicator (orange) |
||
Digital display | Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch
on Catalog.) |
||||
Display orientation | Switching between normal/reversed display is possible. | ||||
Key lock | Key lock | Key lock/Easy key lock. | |||
Ambient illumination
(Receiver side) |
Incandescent lamp: 10,000 lx max.
Sunlight: 20,000 lx max. |
||||
Maximum connectable
Units |
16 (The ambient temperature specification depends on the number of connected
units.) *7 |
||||
Ambient temperature
range |
Operating: Groups of 1 to 2 Amplifiers: -25 to 55°C
Groups of 3 to 10 Amplifiers: -25 to 50°C Groups of 11 to 16 Amplifiers: -25 to 45°C *8 |
||||
Storage: - 30 to 70 °C (with no icing or condensation) | |||||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
Vibration resistance
(Destruction) |
10 to 55 Hz with a
1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
10 to 150 Hz with a
0.7-mm double amplitude for 80 min each in X, Y, and Z directions |
10 to 55 Hz with a 1.5-mm double
amplitude for 2 hours each in X, Y, and Z directions |
||
Shock resistance
(Destruction) |
500 m/s2 for 3 times
each in X, Y, and Z directions |
200 m/s2 for 3
times each in X, Y, and Z directions |
500 m/s2 for 3 times each in X, Y, and
Z directions |
||
Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | ||||
Connection method | Pre-wired (standard
cable length: 2 m) or wire-saving connector |
Connector for
Sensor Communications Unit |
Pre-wired (standard cable length: 2 m) or
wire-saving connector |
||
Weight (packed state) | Pre-wired Models:
Approx. 100 g, Wire- saving Connector Models: Approx. 55 g |
Approx. 55 g | Pre-wired Models: Approx. 100 g, Wire-
saving Connector Models: Approx. 55 g |
||
Mate-
rials |
Case | Polybutylene terephthalate (PBT) | |||
Cover | Polycarbonate (PC) | ||||
Accessories | Instruction Manual |