Size | M12 | M18 | M30 | ||||
---|---|---|---|---|---|---|---|
Model | E2V-X2[][] | E2V-X4[][] | E2V-X5[][] | E2V-X8[][] | E2V-X10[][] | E2V-X15[][] | |
Sensing distance | 2 mm±10% | 4 mm±10% | 5 mm±10% | 8 mm±10% | 10 mm±10% | 15 mm±10% | |
Set distance | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 4.0 mm | 0 to 6.4 mm | 0 to 8.0 mm | 0 to 12.0 mm | |
Differential travel | 10% max. of sensing distance | ||||||
Detectable object | Ferrous metals and non-ferrous metals (The sensing distance depends on the material of
the sensing object. Refer to Engineering Data (Reference value).) |
||||||
Standard sensing object | Aluminum:
12 × 12 × 3 mm |
Aluminum:
12 × 12 × 3 mm |
Aluminum:
18 × 18 × 3 mm |
Aluminum:
24 × 24 × 3 mm |
Aluminum:
30 × 30 × 3 mm |
Aluminum:
45 × 45 × 3 mm |
|
Response frequency * | 150 Hz | 40 Hz | 70 Hz | 40 Hz | 70 Hz | 30 Hz | |
Power supply voltage
(operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | ||||||
Current consumption | 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) | ||||||
Control
output |
Load current | Open-collector output, 100 mA max. | |||||
Residual
voltage |
2 V max. (Load current: 100 mA, Cable length: 2 m) | ||||||
Indicators | NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC
Models: Operation indicator (yellow) (lit) |
||||||
Operation mode | B1/C1 Models: NO
B2/C2 Models: NC (Refer to the timing charts under I/O Circuit Diagrams for details.) |
||||||
Protection circuits | Power supply reverse polarity protection, reversed output polarity protection, load short-
circuit protection, surge suppressor |
||||||
Ambient temperature | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||||
Ambient humidity | Operating/Storage: 35% to 95% (with no condensation) | ||||||
Temperature influence | Based on the sensing distance at 23°C in the temperature range of -25 to 70°C | ||||||
±10% max. | ±15% max. | ±10% max. | ±15% max. | ±10% max. | ±15% max. | ||
Voltage influence | ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions |
||||||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||||
Degree of protection | IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the
OMRON in-house standard.) |
||||||
Connection method | Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector
Models (Standard cable length: 300 mm) |
||||||
Weight
(packed state) |
Cable | Approx. 120 g | Approx. 150 g | Approx. 200 g | |||
Connector | Approx. 30 g | Approx. 45 g | Approx. 120 g | ||||
Pre-wired
Connector Models |
Approx. 50 g | Approx. 70 g | Approx. 140 g | ||||
Materials | Case | Nickel-plated brass | |||||
Sensing
surface |
Heat-resistant ABS | ||||||
Clamping nuts | Nickel-plated brass | ||||||
Toothed
washer |
Zinc-plated iron | ||||||
Accessories | Instruction manual |