V680 series

RFID System

V680 series

RFID Systems with ISO/IEC 18000-3 (15693) Compliance

RF Tag

Type Memory
capacity
Appearance Size Metallic compatibility Model
Battery-
less
1 Kbyte 1863_lu_1_1 8 dia. × 5 mm For embedding in metallic or
non-metallic surface
V680-D1KP52MT
1863_lu_1_2 10 dia. × 4.5 mm For embedding in metallic or
non-metallic surface
V680-D1KP53M
1863_lu_1_3 20 dia. × 2.7 mm For flush mounting on non-
metallic surface
V680-D1KP54T
1863_lu_1_4 34 × 34 × 3.5 mm For flush mounting on
metallic surface
V680-D1KP66MT
For flush mounting on non-
metallic surface
V680-D1KP66T
1863_lu_1_5 95 × 36.5 × 6.5 mm For flush mounting on non-
metallic surface
V680-D1KP66T-SP
1863_lu_1_6 80 dia. × t10 mm For flush mounting on non-
metallic surface
V680-D1KP58HTN
1863_lu_1_7 M10 × 12 mm For mounting as bolts V680-D1KP52M-BT01 *
M8 × 12 mm V680-D1KP52M-BT11 *
2 Kbytes 1863_lu_1_8 8 dia. × 5 mm For embedding in metallic or
non-metallic surface
V680-D2KF52M
1863_lu_1_9 40 × 40 × 5 mm For flush mounting on
metallic surface
V680S-D2KF67M
For flush mounting on
nonmetallic surface
V680S-D2KF67
1863_lu_1_13 86 × 54 × 10 mm For flush mounting on
metallic surface
V680S-D2KF68M
For flush mounting on
nonmetallic surface
V680S-D2KF68
1863_lu_1_10 M10 × 12 mm For mounting as bolts V680-D2KF52M-BT01 *
M8 × 12 mm V680-D2KF52M-BT11 *
8 Kbytes 1863_lu_1_14 40 × 40 × 5 mm For flush mounting on
metallic surface
V680S-D8KF67M
For flush mounting on
nonmetallic surface
V680S-D8KF67
1863_lu_1_15 86 × 54 × 10 mm For flush mounting on
metallic surface
V680S-D8KF68M
For flush mounting on
nonmetallic surface
V680S-D8KF68
1863_lu_1_11 40 × 40 × 4.5 mm For flush mounting on
metallic surface
V680-D8KF67M
For flush mounting on non-
metallic surface
V680-D8KF67
1863_lu_1_12 86 × 54 × 10 mm For flush mounting on non-
metallic surface
V680-D8KF68
32 Kbytes V680-D32KF68

* Place orders in units of boxes (containing 20 units).

Antenna (Detachable Amplifier Unit Type)

Type Appearance Size Cable length Model
Cylindrical Standard cable,
waterproof connector
M22 × 65 mm 2 m V680-HS52-W 2M
12.5 m V680-HS52-W 12.5M
Flexible cable,
non-waterproof connector
2 m V680-HS52-R 2M
12.5 m V680-HS52-R 12.5M
Standard cable,
non-waterproof connector
M12 × 35 mm 2 m V680-HS51 2M
Square Standard cable,
waterproof connector
40 × 53 × 23 mm 2 m V680-HS63-W 2M
12.5 m V680-HS63-W 12.5M
Flexible cable,
non-waterproof connector
2 m V680-HS63-R 2M
12.5 m V680-HS63-R 12.5M
Standard cable,
waterproof connector
100 × 100 × 30 mm 2 m V680-HS65-W 2M
12.5 m V680-HS65-W 12.5M
Flexible cable,
non-waterproof connector
2 m V680-HS65-R 2M
12.5 m V680-HS65-R 12.5M

Antenna with Built-in Amplifier

Type Appearance Size Cable length Model
Square
250 × 200 × 35 mm 0.5 m * V680-H01-V2

* Use an Antenna Cable to connect the Antenna to the Controller.
    The maximum cable length is 30.5 m.

Amplifier Unit

Type Appearance Size Cable length Model
For 1-Kbyte memory
25 × 40 × 65 mm 0.5 m V680-HA63A 0.5M
5 m V680-HA63A 5M
10 m V680-HA63A 10M
For 2-/8-/32-kbyte memory
0.5 m V680-HA63B 0.5M
5 m V680-HA63B 5M
10 m V680-HA63B 10M

ID Controller

Type No. of connectable
Amplifiers
Appearance Size Communication interface Model
DC power supply Single
1863_lu_5_1
105 × 90 × 65 mm RS232C, RS422/RS485 V680-CA5D01-V2
Dual
1863_lu_5_2
V680-CA5D02-V2

ID Sensor Units

Type Unit name Connected
ID System
External
power
supply
No. of unit
numbers
used
Current
consumption (A)
Model
5 V 24 V External
CJ
Special
I/O Unit
1863_lu_6_1
V680
Series
1 Head --- 1 unit number 0.26 0.13 * --- CJ1W-V680C11
2 Heads 2 unit number 0.32 0.26 --- CJ1W-V680C12

Type Unit name Connected
ID System
External
power
supply
No. of unit
numbers
used
Current
consumption (A)
Model
5 V 24 V External
CS
Special
I/O Unit
1863_lu_7_1
V680
Series
1 Head --- 1 unit number 0.26 0.13 * --- CS1W-V680C11
2 Heads 24 VDC 2 unit number 0.32 - 0.36 CS1W-V680C12

* When connected to the V680-H01: 0.28 A

Amplifier-integrated Controller (DeviceNet ID Slave/PROFIBUS ID Slave)

Appearance Size Network Compatibility Model
65 × 65 × 65 mm DeviceNet V680-HAM42-DRT
PROFIBUS V680-HAM42-PRT

Amplifier-integrated Controllers (ID Flag Sensors)

Type Appearance Size Model
NPN output
90 × 30 × 65 mm V680-HAM91
PNP output
V680-HAM81

Special Interface Cables (for V680-HAM91 and V680-HAM81)

Cable length Model Appearance
2 m V680-A60 2M
5 m V680-A60 5M
10 m V680-A60 10M

Note: 1. The connectors are not waterproof.
           2. The cable length can be extended to a maximum of 10 m.
           3. Normally two Interface Cables are required for 1 Unit. If you do not need to write to ID Tags, or use the address
                shift or noise check functions, then one Interface Cable is sufficient.

Handheld Reader Writers

Name Appearance Model
Model with standard serial connector 1863_lu_11_1 V680-CH1D
Model with USB connector and 0.8-m cable V680-CHUD 0.8M
Model with USB connector and 1.9-m cable V680-CHUD 1.9M
Models for Zebra Technologies Handheld Terminal V680-CH1D-PSI
AC Adapter (for V680-CH1D) V600-A22

Accessories (Order Separately)

RF Tag Attachment

Type Appearance Model
For the V680-D1KP66T
1863_lu_12_1
V600-A86
For the V680-D[]KF68
1863_lu_12_2
V680-A81
To mount the V680-D1KP58HTN
1863_lu_12_3
V680-A80
For the V680-D1KP54T
1863_lu_12_4
V700-A80

Amplifier Unit Special Extension Cable (Amplifier Unit to Controller)

Cable length Appearance Model
2 m
V700-A40 2M
3 m V700-A41 3M
5 m V700-A42 5M
10 m V700-A43 10M
20 m V700-A44 20M
30 m V700-A45 30M

Note: The cable can be extended up to 40 m. Up to two extension cables can be used.

V680-H01 Antenna Special Cable (Antenna to Controller)

Cable length Appearance Model
2 m
V700-A40-W 2M
5 m V700-A40-W 5M
10 m V700-A40-W 10M
20 m V700-A40-W 20M
30 m V700-A40-W 30M

Note: The cable can be extended up to 30 m. Only one extension cable can be used.

RS-232C Communications Connector

Name Model
Connector Plug XM3B-0922-111
Connector Hood XM2S-0911

* An RS422/RS485 Communications Connector is attached to the Controller.

ID Map Manager

Type Model
Japanese version V680-A-IMMJP-P02 *
English version V680-A-IMMEG-P02 *
Chinese version V680-A-IMMCN-P02 *

* Supported operating system: Windows 7
For details, consult your OMRON representative.

Zebra Technologies Handheld Terminals

We recommend connecting the V680/V680-CH-PSI Handheld Reader Writer to a Zebra Technologies Work About Pro-series Handheld Terminal.
Zebra Technologies products can be purchased directly from OMRON.

Handheld Terminal Set

Name Configuration OMRON model number
Handheld Terminal Set
(English OS) *1
Handheld Terminal, Serial End Cap, hand strap, charger
(standard model), and High-capacity Battery
V680-A-7528S-G4-EG-S *2

*1. The Handheld Terminal Set includes the V600/V680 EasyAccess/CBAccess Demo Software preinstalled in a
   Work About Pro Zebra Technologies Handheld Terminal and the configuration parts listed above.
*2 For V680-A-7528S-G4-[][]-S, super high-capacity battery model V680-A-WA3010 is installed as standard.
   V680-A-7527S-G3-[][]-S can't be used with a super high-capacity battery model V680-A-WA3010.
    (Because it is different in a battery door.)

Handheld Terminal Accessories

Name Appearance Motorola Solutions model number OMRON model number
Super high-capacity battery 1863_lu_19_1 WA3010 V680-A-WA3010
Standard battery WA3025 V680-A-WA3025 *
Charger (standard model) 1863_lu_19_2 PS1050-G1 V680-A-CA1053
Charger (advanced model) 1863_lu_19_3 WA4003-G2 V680-A-WA4003
Carrying Case 1863_lu_19_4 WA6197-G2 V680-A-WA6197

* V680-A-7528S-G4-[][]-S can't be used with a high-capacity battery model V680-A-WA3006.
  (Because it is different in a battery door.)
  Battery capacity of V680-A-WA3025 is 2,760mAh while V680-A-WA3006 is 3,300mAh.

Refer to the following website for detailed information on Zebra Technologies Handheld Terminals.

https://www.zebra.com/jp/ja.html