Model | KS1-AA1T | |
---|---|---|
Power supply voltage | 24 VDC ±5% | |
Current consumption | Approx. 100 mA | |
Discharge method | High-frequency AC (Approx. 68 kHz) | |
Output voltage | ±2 kV | |
Safety circuit | Outputs alarms for ionization errors | |
Discharge time | 0.8 s max. (at a distance of 50 mm from air outlet) | |
Ion balance | ±15 V or less (at a distance of 50 mm from air outlet) | |
Fluid used | Air (refer to Air Used on Catalog) | |
Amount of | 0.04 ppm or less (when standard nozzle used, at a distance of 300 mm from air outlet and
primary side voltage of |
|
generated ozone | 0.25 MPa) | |
Supplied air flow | Approx. 100 L/min (ANR) (when standard nozzle used, at primary side voltage of 0.15 Mpa) | |
Indicators | Green POWER indicator lit while Ionizer ON, red ALM indicator lit for ionizing errors. | |
Air pressure range | When Standard Nozzle or Flexible Tube Nozzle is used. | 0.02 to 0.25 MPa |
When Standard Nozzle Tube is attached. | 0.02 to 0.12 MPa | |
When Shower Nozzle, Flat Nozzle, or Straight Bar Nozzle is used. | 0.05 to 0.40 MPa | |
Operating ambient
temperature |
0 to 40°C (with no icing or condensation) | |
Operating ambient
humidity |
35% to 65% (with no condensation) | |
Weight | 235 g (Ionizer only) | |
Accessories | One ground lead (2 m) |