E2C-EDA

High Precision Positioning Inductive Proximity Sensor

E2C-EDA

Proximity Sensor with Separate Amplifier Enables Easily Making High-precision Sensitivity Settings.

Sensor Heads

Model E2C-
EDR6-F
E2C-
ED01(-[])
E2C-
ED02(-[])
E2C-
EM02(-[])
E2C-
EM07(-[])
E2C-
EV05(-[])
E2C-
EM02H
3 dia. ×
18 mm
5.4 dia.
× 18 mm
8 dia. ×
22 mm
M10 ×
22 mm
M18 ×
46.3 mm
30 × 14
× 4.8 mm
M12 ×
22 mm
Sensing distance 0.6 mm 1 mm 2 mm 7 mm 5 mm 2 mm
Sensing object Magnetic metal
(The sensing distance will decrease when sensing non-magnetic metal. Refer to
Engineering Data (Reference Value) on Catalog.)
Standard sensing object 5 × 5 × 3 mm 10 × 10 × 3 mm 22 × 22
× 3 mm
15 × 15
× 3 mm
20 × 20
× 3 mm
Material: iron (S50C)
Repeat accuracy *1 1 μm 2 μm 5 μm 2 μm
Hysteresis distance Variable
Temper-
ature
charac-
teristic
*1
Sensor Head 0.3%/°C 0.08%/°C 0.04%/°C 0.2%/°C
Preamplifier and
Amplifier
0.08%/°C
Ambient
temper-
ature
*2
Operating -10°C to 60°C (with no icing or condensation) -10°C to
200°C *3
Storage -10°C
to 60°C
(with no
icing or
con-
densation)
-20°C to 70°C (with no icing or condensation)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 50 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection IEC60529 IP67 IEC60529
IP60 *4
Connection method Connector (standard cable length: 2.5 m (2 m between Head and Preamplifier)
"-F" model cable length: 3.5 m (0.5 m between Head and Preamplifier)
Weight (packed state) Approx. 120 g (Models with protective spiral tube ("-S" models) are approx. 90 g heavier.)
Material Sensor
Head
Case Brass Stainless
steel
Brass Zinc Brass
Sensing
surface
Heat-resistant ABS PEEK
Clamping
nut
--- Nickel-plated brass --- Nickel-
plated brass
Toothed
washer
--- Zinc-plated iron --- Zinc-plated
iron
Preamplifier PES
Accessories Preamplifier Mounting Brackets, Instruction Manual

*1 The repeat accuracy and temperature characteristic are for a standard sensing object positioned midway through the
      rated sensing distance.
*2 A sudden temperature rise even within the rated temperature range may degrade characteristics.
*3 For the Sensor Head only without the preamplifier (−10 to 60°C). With no icing or condensation.
*4 Do not operate in areas exposed to water vapor because the enclosure is not waterproof.

Amplifier Units

Type Advanced Models with Twin Outputs Advanced Models with
External Inputs
Pre-wired
Model
Model with
Wiresaving
Connector
Model for Sensor
Communications
Unit
Pre-wired
Model
Model with
Wiresaving
Connector
Model NPN output E2C-EDA11 E2C-EDA6 E2C-EDA0 *1 E2C-EDA21 E2C-EDA7
PNP output E2C-EDA41 E2C-EDA8 E2C-EDA51 E2C-EDA9
Supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Power consumption 1,080 mW max. (current consumption: 45 mA at power supply voltage of 24 VDC)
Control output Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector output; load current:
50 mA max. (residual voltage: 1 V max.)
Response
time
Super-high-
speed mode
*2
150 μs for operation and
reset respectively
-- 150 μs for operation and reset
respectively
High-speed
mode
300 μs for operation and reset respectively
Standard
mode
1 ms for operation and reset respectively
High-
resolution
mode
4 ms for operation and reset respectively
Functions Differential
detection
Switchable between single edge and double edge detection mode
Single edge: Can be set to 300 μs, 500 μs, 1 ms, 10 ms, or 100 ms
Double edge: Can be set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms.
Timer
function
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Zero-reset Negative values can be displayed.
Zero-reset is accompanied by a change of detection distance.
After zero-reset, some threshold level may also cause a change of the indication by
influence of other settings.
Initial reset Settings can be returned to defaults as required.
Mutual
interference
prevention
Possible for up to 5 Units. *2
Intermittent oscillation method (Response time = (number of Units connected + 1) ×
15 ms)
Hysteresis
settings
Setting range: 10 to 2,000
I/O settings Output setting (Select from channel 2 output, area
output, self-diagnosis, or open circuit detection.)
Input setting (Select from
teaching, fine positioning, zero-
reset, synchronous detection.)
Digital display Select from the following: Incident level + threshold, incident level percentage +threshold,
incident light peak level + incident light bottom level (updated with output), long bar display,
incident level + peak hold, incident level + channel
Display orientation Switching between normal/reversed display is possible.
Ambient temperature
*3
Operating:
When connecting 1 to 2 Units: -10°C to 55°C,
When connecting 3 to 5 Units: -10°C to 50°C,
When connecting 6 to 16 Units: -10°C to 45°C
When used in combination with an EDR6-F
When connecting 3 to 4 Units: -10°C to 50°C,
When connecting 5 to 8 Units: -10°C to 45°C,
When connecting 9 to 16 Units: -10°C to 40°C
Storage: -20°C to 70°C (with no icing)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min
Vibration resistance
(Destruction)
10 to 55 Hz with a 1.5-mm
double amplitude for 2 hours
each in X, Y, and Z directions
10 to 150 Hz with a
0.7-mm double
amplitude for 80
min each in X, Y,
and Z directions
10 to 55 Hz with a 1.5-mm
double amplitude for 2 hours
each in X, Y, and Z directions
Shock resistance
(Destruction)
500 m/s2 for 3 times each in
X, Y, and Z directions
150 m/s2 for 3
times each in X,
Y, and Z directions
500 m/s2 for 3 times each in X,
Y, and Z directions
Degree of protection IEC60529 IP50
Connection method Pre-wired Wire-saving
connector
Connector for Sensor
Communications Unit
Pre-wired Wire-saving
connector
Weight (packed state) Approx. 100 g Approx. 55 g Approx. 55 g Approx. 100 g Approx. 55 g
Material Case PBT (polybutylene terephthalate)
Cover Polycarbonate

*1 This model allow you to use an E3X-ECT EtherCAT Sensor Communications Unit or E3X-CRT CompoNet Sensor
     Communications Unit.
*2 Communications functions, mutual interference prevention, and communications with the Mobile Console are all disabled
     if the detection mode is set to the super-high-speed mode.
*3 The following temperature ranges apply for operation when an E3X-ECT or E3X-CRT Sensor Communications Unit is
     used with the E2C-EDA0: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 5 Amplifier Units: 0 to 50°C,
     Groups of 6 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units (with the E3X-ECT): 0 to 40°C.
     The following temperature ranges apply when an E3X-ECT or E3X-CRT Sensor Communications Unit is used with the
     E2C-EDR6-F: Groups of 3 or 4 Amplifier Units: 0 to 50°C, Groups of 5 to 8 Amplifier Units: 0 to 45°C, Groups of 9 to 16
     Amplifier Units: 0 to 40°C, Groups of 17 to 30 Amplifier Units (with the E3X-ECT): 0 to 35°C.