• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Safety-door Hinge Switch
about this Product Family
last update: May 07, 2015
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1
(certified direct opening) |
Ask your OMRON representative for information on certified models. |
UL * | UL508, CSA C22.2 No.14 | E76675 |
CCC (CQC) | GB14048.5 | 2004010305105973 |
* Certification for CSA C22.2 No. 14 is authorized by the UL mark.
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 10 A | 60 | 6 | 7,200 | 720 |
240 VAC | 30 | 3 |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
125 VDC | 2.5 A | 0.55 | 0.55 | 69 | 69 |
250 VDC | 0.27 | 0.27 |
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 1,000,000 operations min. |
Electrical | 500,000 operations min. (3 A resistive load at 250 VAC) *3
300,000 operations min. (10 A resistive load at 250 VAC) |
|
Operating speed | 2 to 360°/s | |
Operating frequency | 30 operations/minute max. | |
Contact resistance | 25 mΩ max. | |
Minimum applicable load *4 | 1 mA resistive load at 5 VDC (N-level reference value) | |
Rated insulation voltage (Ui) | 300 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class II (double insulation) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand
voltage (EN60947-5-1) |
Between terminals of same
polarity |
2.5 kV |
Between terminals of different
polarity |
4 kV | |
Between each terminal and
non-current carrying metallic parts |
6 kV | |
Insulation resistance | 100 MΩ min. | |
Contact gap | 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 10 A (EN60947-5-1) | |
Ambient operating temperature | -30 to 70°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 87 g (D4NH-1AAS)
Approx. 97 g (D4NH-1ABC) |